Masimo 1896 (LNCS TF-I) Compatible Forehead SpO2 Sensor, Reusable, 3.3 ft (1.0 m)

$100.00

The Masimo 1896 (LNCS TF-I) compatible SpO2 sensor (SKU SS-005RB-FH10) is a reusable, aftermarket replacement (not OEM) forehead sensor for Masimo SET-equipped monitors, built to match the original’s fit, form, and function.

Sensor Type Forehead
Patient Size Adult, >66 lbs (>30 kg)
Connector Masimo LNCS
SpO2 Technology Masimo SET (LNCS)
Cable Length 3.3 ft (1.0 m)
Lifecycle Reusable
Replaces Masimo 1896 (LNCS TF-I), Draeger MP00799

Works with: Masimo Radical-7, Rad-5, Rad-8, and Rad-57; Masimo SET-equipped Mindray/Datascope Passport and Spectrum, GE Dash, Solar, CARESCAPE, and Dinamap, Philips IntelliVue, Physio-Control Lifepak 11 through 20e, Zoll E, M, R, and X Series, Draeger Infinity, and Welch Allyn Connex Spot, Propaq, and Spot Vital Signs monitors. Some monitors require an LNCS patient cable. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.

IPR Medical buys, sells, repairs, and stocks parts for Masimo patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: SS-005RB-FH10 Categories: , Tags: ,
Send In Masimo 1896 (LNCS TF-I) Compatible Forehead SpO2 Sensor, Reusable, 3.3 ft (1.0 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) SS-005RB-FH10
Replaces OEM Part Masimo 1896 (LNCS TF-I)
Category Reusable SpO2 Sensor
Sensor Type Forehead
Patient Size Adult, >66 lbs (>30 kg)
Cable Length 3.3 ft (1.0 m)
Connector Masimo LNCS
SpO2 Technology Masimo SET (LNCS)
Lifecycle Reusable
Packaging 1 Set per Bag

Compatible Monitor Models

Manufacturer Compatible Models
Masimo 9216, 9226, Pronto-7, R7CDS-1, Rad-5, Rad-8, Rad-57, Rad-87, Radical-7
Mindray / Datascope Accutorr 3, Accutorr 7, Accutorr Plus, Accutorr V, BeneView T1, BeneView T5, BeneView T8, BeneVision N1, BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision N22, BeneVision TD60, BeneVision TMS60, BeneVision TMS80, BeneHeart D6, cPM 8, cPM 12, DPM3, DPM4, DPM5, DPM6, DPM7, Duo, EPM4, iMEC 5, iMEC 6, iMEC 7, iMEC 8, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iPM-9800, MEC 12, MPM, Passport 2, Passport 2LT, Passport 8, Passport 12, Passport 12m, Passport 17m, Passport V, Passport XG, PM 6000, PM 6800, PM 7000, PM 8000, PM 9000, Spectrum, Spectrum OR, T8, Trio, V12, V21, VS 8, VS 8A, VS 8C, VS 9, VS 9A, VS 9C, VS 800
GE Healthcare (Marquette) Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Eagle, Eagle 1000, PDM Module, ProCare B40, Solar 7000, Solar 8000, Solar 8000M, i/9500 (Tram 451N5/851N5), Tram 451, TRAM Modular, x50SL Series, SMK SMV
GE Healthcare (Dinamap) B105M, B105P, B125M, B125P, B155M, CARESCAPE B650, CARESCAPE B850, CARESCAPE V100, CARESCAPE VC150, ProCare with Masimo (Pro 1000, Pro 300V2, Pro 400V2), ProCare 300, ProCare Auscultatory 400, ProSeries V2, V300
GE Healthcare (Corometrics) 128, 250, 250cx, 259, TRAM 450SL
Datex-Ohmeda Giraffe Infant Warmer, S/5
Philips Heartstream XL, IntelliVue FAST-SpO2, IntelliVue MP70, M1020B, M2601A, M3000A, M3001A, M3001A A03, M3001A A03C06, M3001A A03C12, M3001A A03C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A MP2, M8105A MP5, M8105AS, MP30, SureSigns VS2, SureSigns VS3, VM4
Physio-Control (Stryker) Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20e
Zoll E Series, M Series, R Series, X Series
Draeger Infinity Delta, Infinity Delta XL, Infinity Kappa, Infinity M540, Narkomed 6400
Welch Allyn 1500, 45NE0-E1 LX, 53S00, 53S0P, 53ST0, 53STP, 64H Series, 64M Series, 65H Series, 65M Series, 67M Series, 68M Series, 73ME-B, 73MT-B, 74ME-B, 74MT-B, 74MX-B, 75MT-B Connex Spot, 75ME-B, 75MX-B, Propaq CS, Propaq LT, Series 420, Spot Vital Signs 42MOB, Spot Vital Signs 42MTB-E1, Spot Vital Signs LXi, Vital Signs 4700 Series
Invivo Escort II OPT30 Prism, T8
Respironics Alice 5, Alice 6
CASMed 740
Natus Connex
Bitmos sat 800, sat 801, sat 805, sat 816, satPuls
Comen K12 Pro
Mennen Horizon XVu
Penlon InterMed Masimo SET-Equipped Models

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Masimo 1896 (LNCS TF-I)
Draeger MP00799
Spacelabs 690-0250-00

IPR Medical buys, sells, repairs, and stocks parts for the Masimo 1896 LNCS TF-I Forehead Sensor. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, Philips, or any other manufacturer or supplier named on this page. Masimo, Philips, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Compatible Masimo 1896 LNCS TF-I Forehead Sensor?

The Masimo 1896 (LNCS TF-I) compatible SpO2 sensor (IPR SKU SS-005RB-FH10) is a reusable forehead sensor for monitors that use Masimo SET pulse oximetry with an LNCS sensor interface. It is a compatible aftermarket replacement, not an OEM Masimo product, built to match the fit, form, and function of the original TF-I sensor. Instead of passing light through a finger, a forehead sensor reads reflected light from the vascular bed above the brow. This site stays well perfused when peripheral circulation drops, so clinicians often turn to it for patients with cold extremities, vasoconstriction, or low cardiac output. The 3.3 ft (1.0 m) cable ends in a Masimo LNCS connector, which plugs directly into LNCS-equipped Masimo devices or into an LNCS patient cable on other brands’ monitors that use Masimo SET technology.


Compatible Monitor Models

This compatible sensor works across a very broad installed base of Masimo SET-equipped devices. Compatibility includes Masimo Radical-7, Rad-5, Rad-8, Rad-57, Rad-87, and Pronto-7; Mindray and Datascope Passport, Spectrum, Accutorr, BeneView, BeneVision, DPM, iMEC, VS, and PM series monitors; GE Healthcare Dash, Solar, Eagle, Tram, CARESCAPE B650, B850, V100, and VC150, and Dinamap B105, B125, B155, and ProCare monitors, plus Corometrics fetal monitors; Philips IntelliVue MP-series and M3001A MMS configurations, SureSigns VS2 and VS3, and Heartstream XL; Physio-Control Lifepak 11, 12, 15, 20, and 20e; Zoll E, M, R, and X Series; Draeger Infinity Delta, Kappa, M540, and Narkomed 6400; Welch Allyn Connex Spot, Propaq, Spot Vital Signs, and 4700 Series; and Datex-Ohmeda S/5 and Giraffe Infant Warmer. The Specifications tab lists every compatible model. Confirm that your device is configured for Masimo SET oximetry, and whether it requires an LNCS patient cable, before ordering.


Design and Construction

The sensor places its emitter and detector side by side in a flat housing that sits against the forehead just above the eyebrow, where it measures light reflected from the underlying tissue. Proper placement and gentle, even contact are important for a stable signal, so follow your facility’s protocol for positioning and securing forehead sensors. The 3.3 ft (1.0 m) cable terminates in a Masimo LNCS connector. The sensor is reusable and supplied as one set per bag.


When to Replace Your 1896 LNCS TF-I Forehead Sensor

Reusable forehead sensors wear at the sensor face, the cable strain relief, and the connector. Replace the sensor when the emitter or detector windows are scratched, cloudy, or discolored, the sensor housing is cracked, the LNCS connector is damaged or has bent pins, or the cable jacket shows cuts or kinks. Persistent “sensor off” alarms, low signal quality on a properly positioned sensor, or readings that drop out when the patient moves also point to a failing sensor. If a sensor fails to read on a monitor that passes self-test, try a known-good sensor and patient cable to isolate the fault quickly.


Cross Reference and Interchange Part Numbers

This compatible sensor cross-references to Masimo 1896 (LNCS TF-I), Draeger MP00799, and Spacelabs 690-0250-00. When matching to your existing stock, confirm the forehead sensor style and LNCS connector rather than relying on cable length alone.


Why Source Masimo-Compatible SpO2 Sensors from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for infusion pumps and patient monitoring equipment. Compatible reusable SpO2 sensors give ICUs, ORs, EMS agencies, and materials managers a cost-effective way to keep Masimo SET-equipped monitors in service across multiple brands without paying OEM pricing. Our team can confirm fit against your monitor model and patient cable before you order, and we also offer in-house repair services, replacement parts, and refurbished equipment, so you can source accessories and service from a single partner.

IPR Medical buys, sells, repairs, and stocks parts for the Masimo 1896 LNCS TF-I Forehead Sensor. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, Philips, or any other manufacturer or supplier named on this page. Masimo, Philips, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.