Masimo 2317 (LNCS Adtx-3) Compatible Adult Adhesive SpO2 Sensor, Disposable, 3.0 ft (0.9 m), Box of 20

$269.00

The Masimo 2317 (LNCS Adtx-3) compatible SpO2 sensor (SKU SSD-005RB-W09A) is a disposable, aftermarket replacement (not OEM) adult adhesive sensor for Masimo SET-equipped monitors, built to match the original’s fit, form, and function.

Sensor Type Non-Woven Adhesive (Finger)
Patient Size Adult, >66 lbs (>30 kg)
Connector Masimo LNCS, Male 9-Pin
SpO2 Technology Masimo SET (LNCS)
Cable Length 3.0 ft (0.9 m)
Lifecycle Disposable, Latex-Free
Packaging 20 per Box
Replaces Masimo 2317, Draeger MP00790, Philips 989803148231, and more

Works with: Masimo Radical-7, Rad-5, Rad-8, and Rad-57; Masimo SET-equipped Mindray/Datascope Passport and Spectrum, GE Dash, Solar, and CARESCAPE, Philips IntelliVue, Physio-Control Lifepak 11 through 20e, Zoll E, M, R, and X Series, Draeger Infinity, and Welch Allyn Propaq and Spot Vital Signs monitors. Some monitors require an LNCS patient cable. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.

IPR Medical buys, sells, repairs, and stocks parts for Masimo patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: SSD-005RB-W09A Categories: , Tags: ,
Send In Masimo 2317 (LNCS Adtx-3) Compatible Adult Adhesive SpO2 Sensor, Disposable, 3.0 ft (0.9 m), Box of 20 for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) SSD-005RB-W09A
Replaces OEM Part Masimo 2317 (LNCS Adtx-3)
Category Disposable SpO2 Sensor
Sensor Type Non-Woven Adhesive (Finger)
Patient Size Adult
Patient Weight Range >66 lbs (>30 kg)
Cable Length 3.0 ft (0.9 m)
Connector Masimo LNCS, Male 9-Pin D-Sub, Triple Keyed
SpO2 Technology Masimo SET (LNCS)
Lifecycle Disposable, Single-Patient Use
Latex-Free Yes
Sterility Non-Sterile
Packaging 20 per Box

Compatible Monitor Models

Manufacturer Compatible Models
Masimo Pronto-7, Rad-5, Rad-8, Rad-57, Rad-87, Radical-7
Mindray / Datascope Accutorr 3, Accutorr 7, Accutorr Plus, Accutorr V, BeneView T1, BeneView T5, BeneView T8, BeneVision N1, BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision N22, BeneVision TMS60, BeneVision TMS80, BeneHeart D6, cPM 8, cPM 12, DPM4, DPM6, DPM7, Duo, ePM 10M, ePM 12M, EPM4, iMEC 5, iMEC 6, iMEC 7, iMEC 8, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iPM-9800, MEC 12, MPM, Passport 2, Passport 2LT, Passport 8, Passport 12, Passport V, Passport XG, PM 6000, PM 6800, PM 7000, PM 8000, PM 9000, Spectrum, Spectrum OR, T8, Trio, V12, V21, VS 8, VS 8A, VS 8C, VS 9, VS 9A, VS 9C, VS 800
GE Healthcare (Marquette) Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Eagle, Eagle 1000, PDM Module, ProCare B40, Solar 7000, Solar 8000, Solar 8000M, i/9500 (Tram 451N5/851N5), Tram 451, TRAM Modular, x50SL Series, SMK SMV
GE Healthcare (Dinamap) CARESCAPE B650, CARESCAPE B850, CARESCAPE V100, ProCare with Masimo (Pro 1000, Pro 300V2), ProCare 300, ProCare Auscultatory 400, ProSeries V2, V300
GE Healthcare (Corometrics) 128, 250, 250cx, TRAM 450SL
Datex-Ohmeda Giraffe Infant Warmer, S/5
Philips Heartstream XL, IntelliVue FAST-SpO2, IntelliVue MP70, M1020B, M2601A, M3000A, M3001A, M3001A A03, M3001A A03C06, M3001A A03C12, M3001A A03C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A MP2, M8105A MP5, M8105AS, MP30, SureSigns VS2, SureSigns VS3, VM4
Physio-Control (Stryker) Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20e
Zoll E Series, M Series, R Series, X Series
Draeger Infinity Delta, Infinity Delta XL, Infinity Kappa, Infinity M540, Narkomed 6400
Welch Allyn 1500, 45NE0-E1 LX, 53S00, 53S0P, 53ST0, 53STP, 64H Series, 64M Series, 65H Series, 65M Series, 67M Series, 68M Series, Propaq CS, Propaq LT, Spot Vital Signs 42MOB, Spot Vital Signs 42MTB-E1, Spot Vital Signs LXi
Invivo Escort II OPT30 Prism, T8
Bitmos sat 800, sat 801, sat 805, sat 816, satPuls
Comen K12 Pro
Mennen Horizon XVu
Respironics Alice 5
Penlon InterMed Masimo SET-Equipped Models

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Masimo 2317 (LNCS Adtx-3), 1859 (LNCS Adtx, 18 in)
Datascope (Mindray) 0600-00-0121, 520A-30-64101
Draeger MP00790
GE Healthcare (Marquette) 2027253-001, 2066333-001
Philips 989803148231
Physio-Control (Stryker) 11171-000019 (18 in)
Spacelabs 690-0251-00 (18 in)
Zoll 8000-0320 (18 in)

IPR Medical buys, sells, repairs, and stocks parts for the Masimo 2317 LNCS Adtx-3 SpO2 Sensor. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, Philips, or any other manufacturer or supplier named on this page. Masimo, Philips, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Compatible Masimo 2317 LNCS Adtx-3 SpO2 Sensor?

The Masimo 2317 (LNCS Adtx-3) compatible SpO2 sensor (IPR SKU SSD-005RB-W09A) is a single-patient-use adhesive finger sensor for adult patients on Masimo SET-equipped monitors. It is a compatible aftermarket replacement, not an OEM Masimo product, built to match the fit, form, and function of the original. The sensor has a non-woven adhesive wrap and a 3.0 ft (0.9 m) cable that ends in a Masimo LNCS connector. It plugs directly into LNCS-equipped Masimo devices, or into an LNCS patient cable on other brands’ monitors that use Masimo SET technology. Adhesive sensors stay in place during patient movement and transport, and single-patient use removes the need to reprocess reusable sensors between patients.


Compatible Monitor Models

Because LNCS is the most widely licensed Masimo sensor interface, this compatible sensor works across a very broad installed base. Compatibility includes Masimo Radical-7, Rad-5, Rad-8, Rad-57, Rad-87, and Pronto-7; Mindray and Datascope Passport, Spectrum, Accutorr, BeneView, BeneVision, ePM, iMEC, VS, and PM series monitors; GE Healthcare Dash, Solar, Eagle, Tram, and CARESCAPE B650, B850, and V100 monitors, plus Dinamap ProCare and Corometrics fetal monitors; Philips IntelliVue MP-series and M3001A MMS configurations, SureSigns VS2 and VS3, and Heartstream XL; Physio-Control Lifepak 11, 12, 15, 20, and 20e; Zoll E, M, R, and X Series; Draeger Infinity Delta, Kappa, M540, and Narkomed 6400; Welch Allyn Propaq, Spot Vital Signs, and Connex-era 64, 65, 67, and 68 series; and Datex-Ohmeda S/5 and Giraffe Infant Warmer. The Specifications tab lists every compatible model. Confirm that your device is configured for Masimo SET oximetry, and whether it requires an LNCS patient cable, before ordering.


Design and Construction

The non-woven adhesive wrap conforms to the fingertip and holds the emitter and detector in alignment through patient movement, which makes it well suited for continuous monitoring in the ICU, OR, ED, and during transport. The sensor is sized for adult patients weighing more than 66 lbs (30 kg). The 3.0 ft (0.9 m) cable terminates in a triple-keyed male 9-pin LNCS connector. Each sensor is single-patient use, latex-free, and non-sterile, and sensors are packaged 20 per box.


When to Replace Your 2317 LNCS Adtx-3 SpO2 Sensor

Adhesive sensors are designed for a single patient and should be discarded when that patient is discharged or the sensor is removed. Replace the sensor sooner if the adhesive no longer holds securely, the sensor becomes soiled or wet, the emitter or detector shifts off the nail bed, or the site needs to be rotated per your facility’s skin-integrity protocol. Persistent “sensor off” or low-signal alarms on a well-perfused patient are also a cue to apply a fresh sensor at a new site. Keeping adequate box stock on each unit prevents staff from reusing sensors past their intended life.


Cross Reference and Interchange Part Numbers

This compatible sensor cross-references to Masimo 2317 (LNCS Adtx-3) and 1859 (LNCS Adtx), and to the OEM-labeled equivalents sold under other monitor brands, including Datascope 0600-00-0121 and 520A-30-64101, Draeger MP00790, GE Healthcare 2027253-001 and 2066333-001, Philips 989803148231, Physio-Control 11171-000019, Spacelabs 690-0251-00, and Zoll 8000-0320. The Masimo 1859, Physio-Control 11171-000019, Spacelabs 690-0251-00, and Zoll 8000-0320 references are the 18-inch-cable version of the same adult adhesive sensor. This listing is the 3.0 ft (0.9 m) version.


Why Source Masimo-Compatible SpO2 Sensors from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for infusion pumps and patient monitoring equipment. Compatible disposable SpO2 sensors are one of the highest-volume consumables on any unit, and sourcing them as compatible replacements gives materials managers meaningful savings over OEM pricing without changing workflows. Our team can confirm fit against your monitor model and patient cable before you order, and we also offer in-house repair services, replacement parts, and refurbished equipment, so you can source consumables and service from a single partner.

IPR Medical buys, sells, repairs, and stocks parts for the Masimo 2317 LNCS Adtx-3 SpO2 Sensor. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, Philips, or any other manufacturer or supplier named on this page. Masimo, Philips, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.