Masimo Compatible SpO2 Adapter Cable LNCS>Nellcor (SA-005RB-03)
The Masimo compatible SpO2 adapter cable, LNCS to Nellcor (SKU SA-005RB-03) is a reusable, aftermarket replacement (not OEM) adapter that allows Nellcor-style SpO2 sensors to be used on monitors and pulse oximeters equipped with Masimo LNCS technology.
| Cable Type | SpO2 Adapter Cable |
| Function | Adapts Nellcor-style SpO2 sensors to Masimo LNCS-equipped monitors and pulse oximeters |
| Cable Length | 1 ft (0.3 m) |
| Lifecycle | Reusable |
| Unit of Measure | 1 each |
Works with: select Masimo LNCS-equipped monitors and pulse oximeters from Masimo, GE Healthcare, Mindray, Physio-Control, Welch Allyn, Zoll, and others. See the Specifications tab for the full list. Browse our full selection of SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for the patient monitors and pulse oximeters this adapter supports. Call 855-477-8866 or email cs@iprmed.com.
Product Specifications
| Product Type | Compatible aftermarket SpO2 adapter cable |
| Function | Adapts Nellcor-style SpO2 sensors for use on Masimo LNCS-equipped monitors and pulse oximeters |
| SKU / Part Number | SA-005RB-03 |
| Cable Length | 1 ft (0.3 m) |
| Instrument-Side Connector | 9-pin D-sub male, triple keyed (LNCS style) |
| Sensor-Side Connector | 9-pin D-sub female (accepts Nellcor-style sensor connectors) |
| Cable Color | Gray |
| Cable Diameter | 0.16 inches (4 mm) |
| Lifecycle | Reusable |
| Latex-Free | Yes |
| Sterile | No (non-sterile) |
| Unit of Measure | 1 each |
| Certifications | FDA, CE, CFDA; ISO 80601-2-61 and RoHS compliant |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Bitmos | sat 800, sat 801, sat 805, sat 816, satPuls |
| Comen | K12 Pro |
| Drager | Infinity M540, Narkomed 6400 |
| GE Healthcare | 128, 250, 250cx, TRAM 450SL, Giraffe Infant Warmer, S/5, B125M, B40, Carescape B650, Carescape B850, B125, Carescape V100, Carescape V100 with Masimo technology, Dash Series, Dinamap ProCare with Masimo Pro 1000, Pro 300V2, ProCare 300, ProCare Ausculatory 400, ProSeries V2, SOLAR Series, V300, 8000 e Eagle 1000, Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Eagle, i/9500, i/9500 (Tram 451N5/851N5), PDM Module, Procare B40, Smk SMV, SOLAR, Solar 7000, Solar 8000, Solar 8000M, Tram 451, TRAM Modular, x50SL Series |
| Invivo | Escort II OPT30 Prism |
| Masimo | Pronto 7, Rad 5, Rad 57, Rad 87, Rad-8, Radical-7 |
| Mennen Medical | Horizon XVu |
| Mindray | Accutor V, Accutorr 3, Accutorr 7, Accutorr Plus, DPM4, DPM6, DPM7, EPM4, MEC 12, MPM, Passport 2LT, Passport XG, PM 6800, T8, V12, V21, VS 800, BeneHeart D6, BeneView T1, BeneView T5, BeneView T8, Duo, IPM Series, Passport 12, Passport 2, Passport 8, Passport V, PM 6000, PM 7000, PM 8000, PM 9000, Spectrum, Spectrum OR, TM80, Trio |
| Philips | IntelliVue MX700 Masimo Rainbow |
| Physio-Control | Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E |
| Spacelabs | Qube |
| Respironics | Alice 5 |
| Venni | All |
| Welch Allyn | 1500, 45NE0-E1 LX, Propaq CS, Propaq LT, Spot Vital Signs 42MTB-E1, Spot Vital Signs LXi |
| Zoll | E Series, M Series, R Series, X Series |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| IPR Medical | SA-005RB-03 |
| 360Biomedical | 360Bio-4849 |
| Argo Biomedical | ARSA-005RB-03 |
| Cables and Sensors | 10248 |
| Gopher | GMSA-005RB-03 |
| MARS | MARS-MAS-NCSNEL |
| Medicable | MCSA005RB03 |
| PartsSource | HW-HEMO-00014 |
| Revanix | RVBSA005RB031 |
IPR Medical buys, sells, repairs, and stocks parts for the Masimo compatible SpO2 Adapter Cable (LNCS>Nellcor) and the patient monitors it supports. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Masimo, Philips, or any other manufacturer or supplier named on this page. Nellcor, Masimo, Philips, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Masimo Compatible SpO2 Adapter Cable LNCS>Nellcor?
The SA-005RB-03 is a compatible aftermarket SpO2 adapter cable that bridges two of the most common pulse oximetry ecosystems in the hospital: it allows Nellcor-style SpO2 sensors to be used on monitors and pulse oximeters running Masimo LNCS technology. For facilities operating a mixed fleet of pulse oximeters, this short 1 ft (0.3 m) adapter makes it possible to standardize on a single sensor inventory rather than stocking separate sensors for every monitor brand on the floor. It is offered as a compatible replacement designed to match the fit and function of the equivalent OEM adapter; it is not an OEM Masimo product, and IPR Medical is not affiliated with Masimo, Nellcor, or any original equipment manufacturer.
Compatible Monitor Models
This adapter cable is used with Masimo pulse oximeters including the Rad 5, Rad-8, Rad 57, Rad 87, Radical-7, and Pronto 7, along with a wide range of multi-parameter monitors and defibrillators built on Masimo SpO2 technology. Supported equipment includes GE Healthcare Dash, Solar, TRAM, and Carescape series monitors, Mindray Passport, Accutorr, BeneView, and PM series monitors, Physio-Control Lifepak 11, 12, 15, 20, and 20E defibrillators, Zoll E, M, R, and X Series units, and Welch Allyn Propaq and Spot Vital Signs devices, as well as select models from Drager, Comen, Bitmos, Invivo, Mennen Medical, Philips, Spacelabs, Respironics, and Venni. The complete model-by-model compatibility list appears in the Specifications tab; if your monitor is not shown, contact IPR Medical before ordering and we will confirm fitment for your equipment.
Design and Construction
This adapter is built as a short, durable interconnect for daily clinical use. The gray cable jacket measures 0.16 inches (4 mm) in diameter and runs 1 ft (0.3 m) end to end, keeping the adapter compact at the bedside without adding slack to the sensor line. The instrument side terminates in a triple-keyed 9-pin D-sub male connector in the LNCS style, while the sensor side carries a 9-pin D-sub female connector that accepts Nellcor-style sensor plugs. The assembly is latex-free, supplied non-sterile, and rated for reusable service, and the design is manufactured to FDA, CE, and CFDA requirements with ISO 80601-2-61 and RoHS compliance.
When to Replace Your SpO2 Adapter Cable
Adapter cables sit at the highest-wear point of the SpO2 chain, connected and disconnected many times a day as sensors are swapped between patients. Replace the adapter when you see intermittent or dropped SpO2 readings, repeated sensor-not-detected or sensor-off messages that clear when the adapter is swapped, visible damage such as a cracked connector housing, bent or corroded pins, or a kinked and stiffened cable jacket, or when readings only hold while the cable is held at a certain angle. Because a failing adapter can mimic a failing sensor, many biomedical departments keep spare adapters on the shelf to isolate faults quickly and keep monitors in service.
Cross Reference and Interchange Part Numbers
The SA-005RB-03 cross-references directly to a number of interchange part numbers used across the industry for the same LNCS-to-Nellcor adapter, including 360Biomedical 360Bio-4849, Argo Biomedical ARSA-005RB-03, Cables and Sensors 10248, Gopher GMSA-005RB-03, MARS MARS-MAS-NCSNEL, Medicable MCSA005RB03, PartsSource HW-HEMO-00014, and Revanix RVBSA005RB031. If your purchasing system or equipment records reference any of these part numbers, this adapter cable serves as the matching compatible replacement. The full cross-reference table is available in the Specifications tab for quick lookup.
Why Source SpO2 Adapter Cables from IPR Medical?
IPR Medical buys, sells, repairs, and stocks parts for infusion pumps and patient monitoring equipment, including the monitors, pulse oximeters, and defibrillators this adapter supports. Every compatible accessory we stock is selected to deliver dependable performance at a meaningful savings over OEM pricing, and our team can help you confirm fitment against your monitor model or existing part number before you buy. Whether you need a single adapter cable or fleet quantities for a sensor standardization project, we ship quickly and back every order with responsive, knowledgeable support from a team that services this equipment every day.
IPR Medical buys, sells, repairs, and stocks parts for the Masimo compatible SpO2 Adapter Cable (LNCS>Nellcor) and the patient monitors it supports. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Masimo, Philips, or any other manufacturer or supplier named on this page. Nellcor, Masimo, Philips, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.