Physio-Control 11110-000110 Compatible 10-Lead ECG Trunk Cable, Defib-Proof, AHA, 8.2 ft (2.5 m)

$120.00

The Physio-Control 11110-000110 compatible 10-lead ECG trunk cable (SKU ET-10039R-MD-A) is a reusable aftermarket replacement (not OEM) with limb and chest lead placement, AHA designation, a defib-proof feature, and an 8.2 ft (2.5 m) length.

Lead Count 10-Lead
Lead Placement Limb + Chest Lead
AHA/IEC Code AHA
Feature Defib-Proof (with Resist)
Cable Length 8.2 ft (2.5 m)
Replaces Physio-Control 11110-000110

Works with: select Physio-Control Lifepak models, listed in full on the Specifications tab. Browse more ECG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for patient monitors, ECG trunk cables, and leadwires. Call 855-477-8866 or email cs@iprmed.com.

SKU: ET-10039R-MD-A Categories: , Tags: ,
Send In Physio-Control 11110-000110 Compatible 10-Lead ECG Trunk Cable, Defib-Proof, AHA, 8.2 ft (2.5 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) ET-10039R-MD-A
Replaces OEM Part Physio-Control 11110-000110
Category Cables & Sensors > ECG/EKG
Product ECG Trunk Cable
Lead Count 10-Lead
Lead Placement Limb + Chest Lead
AHA/IEC Code AHA
Feature Defib-Proof (with Resist)
Lead Type Medtronic
Cable Length 8.2 ft (2.5 m)
Intended Use Monitoring
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Physio-Control Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Physio-Control 11110-000110, 805265-23
Unimed MD-21027

IPR Medical buys, sells, repairs, and stocks parts for ECG trunk cables and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Physio-Control, Medtronic, or any other manufacturer or supplier named on this page. Physio-Control, Medtronic, Lifepak, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Physio-Control 11110-000110 Compatible 10-Lead ECG Trunk Cable?

The IPR Medical ET-10039R-MD-A is a compatible aftermarket (not OEM) 10-lead ECG trunk cable that replaces the Physio-Control 11110-000110. A trunk cable carries the signals from the patient leadwires back to the monitor; this one is configured for limb and chest lead placement, uses AHA designation, and runs 8.2 ft (2.5 m). It is reusable, listed as defib-proof, and intended for ECG monitoring.


Compatible Monitor Models

Five select Physio-Control models are listed for this trunk cable: the Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, and Lifepak 20E. A quick look at the Compatible Monitor Models table on the Specifications tab, before the order goes in, avoids a mismatch with the monitor you support.


Design and Construction

As a 10-lead cable, the ET-10039R-MD-A serves both limb and chest placement and follows AHA designation. It measures 8.2 ft (2.5 m) and carries a defib-proof feature. The Lead Type row of the Specifications table identifies the leadwire style it is used with, so compare that row with the leadwires you already have on hand. The cable is reusable and packed one per bag; clean it between patients as your facility protocol directs.


When to Replace Your 10-Lead ECG Trunk Cable

With all ten lead signals running through one cable, a failing trunk tends to show up on several channels at once: multiple flat or noisy traces, lead-off alarms that persist after fresh electrodes go on, or a signal that drops out as the cable flexes. Inspect the jacket for cracks or kinks, both connector housings for damage, and the monitor end for bent pins. Keeping the leadwires and monitor the same while trying a known-good trunk cable shows quickly whether this cable is the fault.


Cross Reference and Interchange Part Numbers

Physio-Control 11110-000110 is the primary reference for this compatible trunk cable, and Physio-Control 805265-23 cross-references to it as well. One aftermarket interchange number rounds out the list; it appears with its brand in the cross-reference table on the Specifications tab.


Why Source ECG Trunk Cables from IPR Medical?

Trunk cables sit alongside the monitor and infusion pump parts that IPR Medical buys, sells, repairs, and stocks as an ISO 9001:2015-certified independent service organization. Our own technicians carry out repairs in-house. For this trunk cable or a repair question, call 855-477-8866 or visit our ECG cables and leadwires page.

IPR Medical buys, sells, repairs, and stocks parts for ECG trunk cables and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Physio-Control, Medtronic, or any other manufacturer or supplier named on this page. Physio-Control, Medtronic, Lifepak, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.