Masimo 2644 (Red DBI-dc8) Compatible Adult Soft Tip SpO2 Sensor, Long Cable, 20-Pin Direct-Connect, Reusable, 11.8 ft (3.6 m)
The Masimo 2644 (Red DBI-dc8) compatible long cable SpO2 sensor (SKU SS-009RB-AS36) is a reusable, aftermarket replacement (not OEM). This adult soft tip sensor plugs directly into 20-pin Masimo Red devices without a patient cable, and its extended 11.8 ft cable gives extra reach.
| Sensor Type | Soft Tip (Finger) |
| Patient Size | Adult, >66 lbs (>30 kg) |
| Connector | 20-Pin Masimo Red, Direct-Connect |
| Cable Length | 11.8 ft (3.6 m) |
| Lifecycle | Reusable, SpO2 Only |
| Replaces | Masimo 2644 (Red DBI-dc8), Physio-Control 11171-000053, Zoll 8000-0377, Unimed U411S-87 |
Works with: Masimo Radical-7, Rad-5, Rad-8, Rad-57, Rad-87, Rad-97, and Pronto monitors, Masimo-equipped Physio-Control Lifepak 15 and Zoll X Series units, and Welch Allyn Connex Spot. See the Specifications tab for the full list. Need a shorter cable? Ask about our 9.8 ft (3.0 m) or 3.3 ft (1.0 m) versions. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for Masimo patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SS-009RB-AS36 |
| Replaces OEM Part | Masimo 2644 (Red DBI-dc8), Long Cable Version |
| Category | Reusable SpO2 Sensor |
| Sensor Type | Soft Tip (Finger) |
| Patient Size | Adult |
| Patient Weight Range | >66 lbs (>30 kg) |
| Cable Length | 11.8 ft (3.6 m) |
| Connector | 20-Pin Masimo Red, Direct-Connect (No Patient Cable Required) |
| SpO2 Technology | Masimo SET |
| Parameters Supported | SpO2 Only |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Masimo | Pronto, Pronto-7, Pronto with Next Generation SpHb, Rad-5, Rad-5v, Rad-8, Rad-57, Rad-57c, Rad-57cm, Rad-57m, Rad-87, Rad-97, Rad-97 NIBP, Rad-97 with NomoLine Capnography, Radical (20-Pin), Radical-7 |
| Physio-Control (Stryker) | Lifepak 15 |
| Zoll | X Series |
| Welch Allyn | 73MT-B, 74ME-B, 74MX-B, 75ME-B, 75MT-B Connex Spot |
| Comen | K12 Pro |
| Riester | RVS 100 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Masimo | 2644 (Red DBI-dc8, 8 ft) |
| Physio-Control (Stryker) | 11171-000053 (8 ft) |
| Zoll | 8000-0377 (8 ft) |
| Unimed | U411S-87 |
IPR Medical buys, sells, repairs, and stocks parts for the Masimo 2644 Long Cable SpO2 Sensor. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Compatible Masimo 2644 Long Cable SpO2 Sensor?
The Masimo 2644 (Red DBI-dc8) compatible long cable SpO2 sensor (IPR SKU SS-009RB-AS36) is a reusable adult soft tip finger sensor. It plugs directly into devices with a 20-pin Masimo Red SpO2 port. This is a compatible aftermarket replacement, not an OEM Masimo product. It matches the 20-pin direct-connect design of the original and comes with an extended 11.8 ft (3.6 m) cable. The cable runs straight from the sensor to the monitor, so no separate patient cable is needed. The long reach suits bedside setups where a Masimo Rad or Radical oximeter, Lifepak 15, or Zoll X Series sits on a shelf, pole, or cart away from the patient. This sensor is intended for SpO2 monitoring and does not support rainbow co-oximetry parameters.
Compatible Monitor Models
This compatible sensor works with these Masimo pulse oximeters and Pulse CO-Oximeters: Radical-7, Radical (20-pin), Rad-5, Rad-5v, Rad-8, Rad-57, Rad-57c, Rad-57cm, Rad-57m, Rad-87, Rad-97, Rad-97 NIBP, Rad-97 with NomoLine Capnography, Pronto, Pronto-7, and Pronto with Next Generation SpHb. It also works with Masimo-equipped configurations of the Physio-Control Lifepak 15 and Zoll X Series, the Comen K12 Pro, and the Riester RVS 100. Welch Allyn Connex and Spot vital signs monitors are supported too, including the 73MT-B, 74ME-B, 74MX-B, 75ME-B, and 75MT-B. Confirm that your device has a 20-pin Masimo Red SpO2 input before ordering.
Design and Construction
The soft tip wraps the fingertip without the spring pressure of a hard shell clip. That makes extended bedside monitoring more comfortable, reduces pressure points on fragile skin, and helps the sensor stay in place on restless patients. It is sized for adult patients weighing more than 66 lbs (30 kg). The 11.8 ft (3.6 m) cable ends in a 20-pin Masimo Red connector that plugs directly into the device. The sensor is reusable and supplied one per bag.
When to Replace Your Long Cable SpO2 Sensor
Long direct-connect cables get stepped on, pinched in bed rails, and coiled repeatedly. Wear shows up along the cable as well as at the soft tip and the 20-pin connector. Replace the sensor if you see any of these signs: torn, stretched, or hardened soft tip material that no longer holds the finger securely; scratched or discolored emitter or detector windows; a cracked connector or bent pins; or cuts, kinks, or exposed shielding on the cable. Persistent “sensor off” alarms or readings that drop out when the cable moves also point to a failing sensor. If a sensor fails to read on a monitor that passes self-test, try a known-good sensor to isolate the fault quickly.
Cross Reference and Interchange Part Numbers
This compatible sensor cross-references to Masimo 2644 (Red DBI-dc8), Physio-Control 11171-000053, and Zoll 8000-0377. The aftermarket interchange number Unimed U411S-87 also applies. The OEM 2644 uses an 8 ft (2.5 m) cable. This compatible version uses a longer 11.8 ft (3.6 m) cable with the same soft tip sensor, adult sizing, and 20-pin Red connector.
Why Source Masimo-Compatible SpO2 Sensors from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization. We buy, sell, repair, and stock parts for infusion pumps and patient monitoring equipment. Compatible reusable SpO2 sensors are a cost-effective way for hospitals, EMS agencies, and materials managers to keep Masimo-equipped oximeters, monitors, and defibrillators in service without paying OEM pricing. Our team can confirm fit against your device before you order. We also offer in-house repair services, replacement parts, and refurbished equipment, so you can source accessories and service from a single partner.
IPR Medical buys, sells, repairs, and stocks parts for the Masimo 2644 Long Cable SpO2 Sensor. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.


















