Philips Avalon CL Wireless Ultrasound Transducer (866076)
The Philips Avalon CL Wireless Ultrasound Transducer (866076) is the cableless fetal heart rate transducer in the Avalon CL Fetal Transducer System — a Smart Transducer with an onboard microprocessor that captures, processes, and digitally transmits the fetal heart rate signal directly to the Avalon fetal monitor. Its seven-crystal array (six crystals arranged around the perimeter with one in the center, in equilateral triangle geometry) delivers uniform acoustic coverage and strong cardiac detection with minimal repositioning, making it especially effective for twins, triplets, and active labor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same measurement performance as wired Smart Transducers at ranges up to 100 m (300 ft) line of sight.
The 866076 supports Cross-Channel Verification (CCV) to prevent maternal-fetal heart rate confusion, Fetal Movement Profile (FMP) for high-risk pregnancy monitoring, and automatic channel assignment (FHR1/FHR2/FHR3) when multiple transducers are in use. It is watertight for underwater monitoring, weighs approximately 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic pairing and battery recharging.
IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.
Philips Avalon CL Wireless Ultrasound Transducer (866076) Specifications
The Philips 866076 is the cableless ultrasound transducer in the Avalon CL Fetal Transducer System. It delivers continuous external fetal heart rate monitoring using Smart Transducer technology with a seven-crystal array, and supports Cross-Channel Verification and Fetal Movement Profile. It connects to the Avalon CL base station (866074) for use with Avalon FM20/FM30/FM40/FM50 fetal monitors.
| OEM Part Number | 866076 (Philips reference 453564423411) |
| Device Type | Cableless ultrasound transducer (Smart Transducer) |
| Measurement | External fetal heart rate (FHR) via continuous-wave Doppler ultrasound |
| Crystal Array | 7-crystal design — 6 crystals arranged around the perimeter plus 1 centered, in equilateral triangle formations for uniform signal coverage |
| Smart Transducer Technology | Onboard microprocessor performs signal conversion and processing at the transducer; digital transmission to monitor reduces EMI and improves signal quality |
| Cross-Channel Verification (CCV) | Supported — automatically alerts when FHR and maternal heart rate coincide, reducing the risk of MHR-FHR misinterpretation |
| Fetal Movement Profile (FMP) | Supported — Philips-exclusive parameter evaluating fetal heart rate and gross body movements simultaneously |
| Multiple Pregnancy Support | Twins and triplets supported with additional 866076 transducers (up to 3 ultrasound channels per monitor) |
| Automatic Channel Assignment | Monitor automatically assigns FHR1, FHR2, or FHR3 channel regardless of which slot or port is used |
| Transducer Finder LED | Blue Finder LED activates to identify the transducer in use — especially useful for repositioning in multiple pregnancy monitoring |
| Compatible Base Station | Philips Avalon CL Base Station (866074) |
| Compatible Fetal Monitors | Philips Avalon FM20, FM30, FM40, and FM50 |
| Required Monitor Software | Avalon fetal monitor software release J.3 or higher |
| Operating Range | Up to 100 m (300 ft) line of sight from base station |
| Wireless Technology | Philips IntelliVue Instrument Telemetry (Short-Range Radio, IEEE 802.15.4) |
| System Capacity | Up to 4 CL transducers and 2 IntelliVue CL Pods per base station |
| Power Source | Rechargeable Lithium-Ion battery (recharged via base station dock) |
| Water Protection | Fully watertight; rated for underwater monitoring (bath/shower use) |
| Applied Part Classification | Type CF, defibrillation-resistant patient connection |
| Diameter | 3.27 in (83 mm) |
| Weight | Approximately 0.6 lbs (0.27 kg) |
| Operating Temperature | 32°F to 104°F (0°C to 40°C) |
| Charging Temperature | 32°F to 95°F (0°C to 35°C) |
| Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
| Operating Humidity | Less than 95% relative humidity at 104°F (40°C) |
| Storage Humidity | Less than 90% relative humidity at 140°F (60°C) |
| Operating Altitude | -1,640 to 9,840 ft (-500 to 3,000 m) |
| Materials | Latex-free housing; sealed non-user-serviceable enclosure |
| FDA Premarket Notification | K140535 |
| Intended Use | Continuous antepartum and intrapartum fetal heart rate monitoring in a healthcare facility |
| Purchase Scope | Cableless ultrasound transducer only — no base station, other transducers, belts, gel, or accessories included. The Avalon CL Base Station (866074) is required for operation and is sold separately. Contact IPR Medical to build a complete Avalon CL kit. |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon CL Wireless Ultrasound Transducer (866076). Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips.
Seven-crystal array for uniform fetal heart rate detection
The Avalon CL Ultrasound Transducer (866076) uses a seven-crystal piezoelectric array to capture the fetal heart rate via continuous-wave Doppler ultrasound. Six crystals are arranged around the perimeter of the sensing face with one crystal centered, positioned in equilateral triangle formations so that the acoustic beam pattern overlaps uniformly across the entire transducer face. In practical terms, this geometry means clinicians spend less time hunting for the fetal heart with the transducer — the signal is strong across a wider footprint on the maternal abdomen, which is particularly valuable during labor when the fetus moves frequently or when monitoring through higher BMIs.
Smart Transducer: onboard processing, digital transmission
Unlike legacy fetal ultrasound transducers that send raw analog signals down a cable to the monitor for processing, the 866076 is a Smart Transducer — it contains its own microprocessor and signal processing hardware. The Doppler signal is converted and processed at the transducer, then transmitted digitally to the Avalon monitor via the 866074 base station. This architecture delivers cleaner traces, better resistance to electromagnetic interference in busy L&D environments, and more consistent signal quality when multiple transducers are in use on a single patient. It also means the 866076 can be added to any compatible Avalon monitor without recalibration or channel tuning — the digital signal path is self-describing.
Twins, triplets, and automatic channel assignment
Multiple pregnancy monitoring is one of the most demanding scenarios in L&D, and the 866076 is engineered for it. Up to three 866076 transducers can be used simultaneously on a single Avalon monitor for twin or triplet monitoring, and the Avalon system assigns each transducer’s signal to FHR1, FHR2, or FHR3 automatically based on the order of placement — regardless of which base station slot or which port the transducer came from. That automation eliminates one of the most common sources of charting error in multiples monitoring. Combined with Cross-Channel Verification, which compares all active FHR signals in real time and alerts clinicians if two channels show suspiciously similar rates, the system helps prevent both MHR-FHR and fetal-fetal signal confusion.
Fetal Movement Profile for high-risk pregnancies
The 866076 supports Fetal Movement Profile (FMP), a Philips-exclusive parameter that evaluates fetal heart rate and gross body movements simultaneously and presents them as a combined profile on the Avalon monitor. FMP is particularly useful in high-risk pregnancy monitoring and non-stress test workflows, where fetal activity correlated with heart rate accelerations provides clinical assurance. Philips’ published data suggests FMP monitoring can reduce unnecessary secondary testing — which translates into fewer callbacks, fewer biophysical profiles, and better utilization of obstetric ultrasound suites.
Cableless mobility for labor and delivery
Freedom of movement during labor is linked to patient comfort, shorter labor times, and better overall experience. The 866076 eliminates the patient cable entirely — the transducer communicates wirelessly with the Avalon CL Base Station (866074) over Philips IntelliVue Instrument Telemetry at ranges up to 100 m (300 ft) in line of sight. Mothers can walk the halls, use a birthing ball, shower, or labor in a tub without losing the fetal heart rate trace. The transducer housing is fully watertight, so underwater monitoring is explicitly supported for hydrotherapy and water birth protocols.
Works with the entire Avalon FM family
The 866076 is part of the Avalon CL system and requires the Avalon CL Base Station (866074). That base station in turn connects to any fetal sensor socket on the Philips Avalon FM20, FM30, FM40, or FM50 fetal monitor — or to the rear telemetry connectors on the FM40 and FM50. Avalon fetal monitor software release J.3 or higher is required. Up to four CL transducers and two IntelliVue CL Pods can be assigned to a single base station, so a complete cableless kit can monitor twins or triplets plus maternal SpO2 and NBP simultaneously from one hub.
Automatic assignment, charging, and Transducer Finder
Setup is plug-and-play: dock the 866076 in any slot on the base station and it is automatically assigned, paired, and recharged. A green or yellow LED on the transducer confirms when it is ready for use, and the built-in blue Finder LED helps clinicians quickly identify which transducer on the patient corresponds to which trace on the monitor — critical during multiples monitoring or shift change. The internal Lithium-Ion battery powers the device wirelessly throughout labor; charge status is reported to the fetal monitor, and low-battery, out-of-battery, loss-of-radio, and malfunction alarms are all built into the Avalon CL system so clinicians are alerted before the trace is interrupted.
Patient safety and construction
The 866076 is a Type CF applied part, meaning its patient connection is rated for direct cardiac application and is defibrillation-resistant. The housing is latex-free, ergonomically contoured for maternal comfort, and sealed at the factory. The transducer is not user-serviceable for battery replacement, which requires the dedicated Philips CL transducer battery replacement tool used by authorized technicians. IPR Medical handles battery service and housing reseal in-house on customer units.
IPR Medical — sales, repairs, parts, and service
IPR Medical sells refurbished and patient-ready Philips Avalon CL transducers and base stations, and we buy surplus or decommissioned units from facilities upgrading their fetal monitoring fleet. Our service team performs battery replacements, housing seal service, crystal array inspection, front-end repair, and functional testing on the 866076 using Philips-specified procedures and test equipment. We also stock replacement belts, belt buttons, ultrasound transmission gel, and the complete Avalon CL transducer line — so a single call covers the transducer, the accessories, and the service that keeps it running.
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon CL Wireless Ultrasound Transducer (866076). Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips.
| Product Condition |
|---|
Compatible Parts and Accessories
IPR Medical stocks a range of compatible parts and accessories for the Philips Avalon CL Wireless Ultrasound Transducer (866076). The sections below cover the most commonly requested components. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.
Avalon CL System Components
| 866074 | Philips Avalon CL Wireless Transducer Base Station — required for 866076 operation; supports up to 4 CL transducers and 2 CL Pods |
| 866075 | Philips Avalon CL Toco+ MP Cableless Transducer — Toco and Smart Pulse with connector for MECG, DECG, or IUP |
| 866076 | Philips Avalon CL Ultrasound Cableless Transducer — this listing |
| 866077 | Philips Avalon CL ECG/IUP Cableless Transducer — MECG, DECG, and IUP measurement |
Compatible Fetal Monitors
| Avalon FM20 | Mid-tier Philips fetal monitor; connects to 866074 via fetal sensor socket (software J.3+ required) |
| Avalon FM30 | Mid-tier Philips fetal monitor with integrated maternal SpO2; connects to 866074 via fetal sensor socket (software J.3+ required) |
| Avalon FM40 | Advanced Philips fetal monitor; connects to 866074 via fetal sensor socket or rear telemetry connectors |
| Avalon FM50 | Top-tier Philips fetal monitor; connects to 866074 via fetal sensor socket or rear telemetry connectors |
IntelliVue CL Pods (Maternal Vital Signs)
| CL SpO2 Pod | Wireless maternal pulse oximetry pod; dockable on the 866074 base station alongside CL transducers |
| CL NBP Pod | Wireless maternal non-invasive blood pressure pod; enables untethered maternal vitals during labor |
Belts and Patient Accessories
| Transducer Belts (Reusable) | Washable, waterproof abdominal belts for Avalon CL transducers; button-style attachment |
| Transducer Belts (Single-Use) | Disposable abdominal belts for single-patient use; button-style attachment |
| Belt Buttons | Replacement belt attachment buttons for Avalon CL transducers |
| Ultrasound Transmission Gel | Acoustic coupling gel for external fetal Doppler monitoring; hypoallergenic formulations available |
Service and Replacement Parts
| CL Transducer Replacement Battery | Factory-spec rechargeable Lithium-Ion battery; installation requires Philips CL transducer battery replacement tool and qualified technician |
| CL Transducer Battery Replacement Tool | Philips-specified tool used to open and reseal CL transducer housings for authorized battery service |
| Base Station Power Cable | AC mains cable for the 866074 Avalon CL Base Station |
| Base Station Telemetry Interface Cable | Interface cable connecting the 866074 base station to the Avalon fetal monitor |
| Base Station Antenna | Standard antenna for 866074 Avalon CL base station; replacement and extension options available |
IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon CL Wireless Ultrasound Transducer (866076). Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.