Philips Compatible Wireless Toco Transducer for Philips Avalon | M2725A
$1,395.00This is an aftermarket-compatible cordless Toco transducer designed to function as a direct replacement for the M2725A wireless Toco fetal transducer used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50) when paired with the Avalon CTS cordless transducer base station (M2720A). It uses a strain-gauge pressure sensor to detect uterine activity by evaluating the hardness of the maternal abdomen during labor, transmitting the signal wirelessly to the CTS base so the patient retains freedom of movement during antepartum testing and labor and delivery. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.
Device Type
Aftermarket-compatible cordless (wireless) external Toco transducer for fetal/maternal monitoringReplaces / Cross Reference
M2725A cordless Toco transducer (also referenced as part 862488)Compatible Monitors
Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) — used together with the Avalon CTS base station (M2720A)Patient Population
Antepartum testing and labor and delivery; ambulatory patients within the CTS base station’s coverage areaKey Features
Cordless operation, lightweight handheld form factor, waterproof housing for shower/bath use during labor, on-board status indicatorsMounting
Snap-clip belt fixing onto compatible reusable or waterproof fetal monitoring beltsIPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Cordless Transducer System (CTS), including aftermarket-compatible wireless Toco transducers for the M2725A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips Avalon Ultrasound Fetal Transducer
$1,475.00The Philips Avalon Ultrasound Fetal Transducer is a state-of-the-art device designed to deliver precise and continuous monitoring of fetal heart rate and activity. This advanced transducer leverages cutting-edge ultrasound technology to ensure accurate and reliable data, which is crucial for making informed clinical decisions during labor and delivery. Its ergonomic design and lightweight construction ensure patient comfort and ease of use for healthcare providers. The Philips Avalon Ultrasound Fetal Transducer integrates seamlessly with existing Philips fetal monitoring systems, providing a cohesive and efficient workflow in maternity wards. The device features a durable, high-quality build, ensuring consistent performance even in the most demanding clinical settings. Real-time, clear displays and alerts keep healthcare providers informed of any changes in fetal status, allowing for timely interventions. The transducer’s intuitive interface simplifies setup and operation, reducing training time and enhancing overall efficiency. Invest in the Philips Avalon Ultrasound Fetal Transducer for unparalleled accuracy, reliability, and comfort in fetal monitoring.
Brand new units may be available. Please contact us directly for more information.
-
Philips Avalon Toco+ MP Fetal Transducer (M2735A) | DECG/MECG/IUP
$1,495.00The Philips Avalon Toco+ MP Transducer (M2735A) is the most versatile wired Smart Transducer in the Avalon family — it measures uterine activity via external Toco, captures maternal pulse with built-in Smart Pulse, and accepts adapter cables for direct fetal ECG (DECG), maternal ECG (MECG), or intrauterine pressure (IUP). One transducer covers four measurement modes, which is why labor and delivery floors keep the M2735A on hand even when most patients are monitored externally.
The Toco+ MP connects to any of the four fetal sensor sockets on Avalon FM20, FM30, FM40, or FM50 monitors via a standard D-shaped connector. Smart Pulse is always active when the transducer is applied, feeding maternal pulse into the monitor’s Cross-Channel Verification (CCV) feature to reduce the risk of mistaking maternal pulse for fetal heart rate. When DECG, MECG, or IUP monitoring is needed, the user simply plugs the appropriate adapter cable into the transducer’s auxiliary connector — the monitor automatically detects the mode.
OEM Part Number
M2735A (989803143681)Measurements
Toco, Smart Pulse, DECG, MECG, IUPCompatible Monitors
Avalon FM20, FM30, FM40, FM50Connector
D-shaped (plug-and-play to any fetal sensor socket)Auxiliary Connector
7-pin D-type for DECG/MECG/IUP adapter cablesSmart Pulse
Built-in, no separate SpO2 or MECG sensor requiredIPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Toco+ MP Transducer (M2735A). Contact us at 855-477-8866 or cs@iprmed.com.
Also available from IPR Medical:
Philips M2734A / M2734B Smart Toco MP Transducer — wired external Toco with Smart Pulse |
Philips Avalon Ultrasound Fetal Transducer (M2736A) — wired US transducer for external FHR |
Philips Avalon CL Wireless Toco+ MP (866075) — cableless equivalent |
Philips Avalon CL Wireless ECG/IUP (866077) — cableless DECG/MECG/IUP |
Philips Avalon FM50 Fetal Monitor — host monitor -
Philips Avalon CL Wireless Toco+ MP Transducer (866075)
$1,995.00The Philips Avalon CL Wireless Toco+ MP Transducer (866075) is the cableless uterine activity transducer in the Avalon CL Fetal Transducer System — measuring uterine contractions via external Toco while simultaneously capturing maternal pulse through integrated Smart Pulse technology. It also includes a multi-purpose connector that accepts maternal ECG, fetal ECG (DECG), or intrauterine pressure (IUP) sensors, making the 866075 one of the most versatile transducers on the L&D floor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same performance as wired Smart Transducers while letting mothers walk, shower, or reposition during labor at ranges up to 100 m (300 ft) line of sight.
The 866075 is watertight for underwater monitoring, weighs only about 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic pairing and battery recharging.
IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips Avalon Ultrasound Transducer
$1,995.00The Avalon Ultrasound system by Philips is a top-tier solution designed for precise and reliable fetal and maternal monitoring. Featuring advanced ultrasound technology, it ensures accurate and continuous monitoring of fetal heart rate and uterine activity, providing critical insights for informed clinical decisions. Its user-friendly interface and intuitive controls make setup and operation straightforward, allowing healthcare professionals to focus on patient care. The Avalon Ultrasound system boasts seamless integration with existing hospital networks, enhancing workflow efficiency and enabling real-time data sharing. Its compact, ergonomic design ensures easy portability and adaptability to various clinical settings, from labor and delivery rooms to intensive care units. Constructed with high-quality materials, the system promises durability and consistent performance even in demanding environments. Advanced safety features and comprehensive monitoring capabilities make it an indispensable tool for ensuring the well-being of both mother and baby. Invest in the Philips Avalon Ultrasound system for unparalleled accuracy, efficiency, and reliability in fetal and maternal healthcare.
Brand new units may be available. Please contact us directly for more information.
-
Philips Avalon CL Wireless Transducer Base Station (866074)
Original price was: $2,695.00.$2,495.00Current price is: $2,495.00.The Philips Avalon CL Wireless Transducer Base Station (866074) is the hub of the Philips Avalon CL cableless fetal monitoring system — the docking station, charger, and wireless gateway that transforms a wired Avalon fetal monitor into a fully cableless L&D solution. A single 866074 base station docks up to three cableless fetal transducers (866075 Toco+ MP, 866076 Ultrasound, and 866077 ECG/IUP) plus one maternal parameters slot for an IntelliVue CL Pod or range extension module, with a total assignment capacity of four CL transducers and two CL Pods. It connects to any Philips Avalon FM20, FM30, FM40, or FM50 fetal monitor via the fetal sensor socket — or to the rear telemetry connectors on the FM40 and FM50 — and delivers a line-of-sight operating range of up to 100 m (300 ft).
Docked transducers and pods are assigned and recharged automatically, so labor teams can grab a patient-ready device and apply it with no setup. The 866074 base station is required for all Avalon CL transducers and pods. IPR Medical sells, buys, repairs, and stocks parts for the Philips Avalon CL system — including base stations, transducers, antennas, power supplies, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.