Hospira Gemstar Blue
The GemStar Pump is a small and lightweight, single-channel infusion device designed for use in the home, in the hospital, or anywhere electronic infusion is required. The GemStar Pump can be powered by AC mains adaptor, rechargeable battery pack, docking station, or two disposable AA alkaline or lithium batteries. When powered by batteries, the GemStar Pump is ideal for ambulatory patients.
Hospira Gemstar Blue Offers 7 Therapy Features:
- Pain Management
- TPN
- Continuous
- Variable Time
- Weight Dosed
- Intermittent
- mL/hr Only
-
B Braun Outlook 100
The Outlook™ 100 is intended for use with B. Braun Medical Inc. Horizon® Pump IV Sets to regulate the flow of primary and secondary fluids when positive pressure is required. The infusion system is capable of delivering fluid from a negative head height (when the IV fluid container is lower than the pump), and provides clinically accepted volumetric accuracy for all standard IV fluids, including blood, lipids, and Total Parenteral Nutrition (TPN).
Positive pressure is frequently a necessity, but clinical experience shows that high pressure limits may increase the severity of an infiltration without causing an alarm. Because there is a need to control pump pressure settings, the Outlook ES has user-selectable Occlusion Limit settings which start at 75 mmHg and extend to 750 mmHg.
The pump is equipped with distinct audible and visual alarm signals to indicate Keep Vein Open (KVO), low battery, and other alarm conditions.
Features
- Promotes patient safety by helping to avoid accidental under- or overdosing using audible
- and visual alerts
- Provides flexibility for each care area—ability to customize dose limits to your hospital drug formulary
- Promotes clinician choice with dose limit override when limits are exceeded during manual programming and titration
- Visually indicates dose selection with DoseGuard™ software
- Easy to learn:
– Manual operation RATE, VOLUME, RUN
– Automatic Dose Rate Calculator
– Large, highly visible keys
- Reduce nuisance air-in-line alarms with air-trapping cassette
- Stackable modular design reduces bedside cord clutter and errors due to channel confusion
- Comprehensive line of needle-free administration sets including UV light resistant tubing that protects drug efficacy
-
B Braun Outlook 100es
The Outlook ES is intended for use with B. Braun Medical Inc. Horizon Pump IV Sets to regulate the flow of primary and secondary fluids when positive pressure is required. The infusion system is capable of delivering fluid from a negative head height (when the IV fluid container is lower than the pump), and provides clinically accepted volumetric accuracy for all standard IV fluids, including blood, lipids, and Total Parenteral Nutrition (TPN).
Positive pressure is frequently a necessity, but clinical experience shows that high pressure limits may increase the severity of an infiltration without causing an alarm. Because there is a need to control pump pressure settings, the Outlook ES has user-selectable Occlusion Limit settings which start at 75 mmHg and extend to 500 mmHg. For epidural infusions which require higher pressures, the pump has an extended occlusion limit setting of 750 mmHg.
The pump is equipped with distinct audible and visual alarm signals to indicate Keep Vein Open (KVO), low battery, and other alarm conditions.
Features
- Promotes patient safety by helping to avoid accidental under- or overdosing using audible and visual alerts for soft/hard dose limits.
- Provides the ability to customize up to 300 drugs and 15 care areas to match your drug formulary, using the expanded DoseGuard drug library.
- Provides reliable operation and accuracy using a proven delivery mechanism.
- Provides comprehensive “at-a-glance” viewing of infusion status on a large color screen.
- Promotes quick and easy drug selection using an active alphabetic drug library matrix.
- Promotes safer and more confident programming with color-coded key pad and audible key clicks.