Philips M1196A / M1196AL Compatible Adult Finger Clip SpO2 Sensor, Hard Shell, Philips FAST, 9.8 ft (3.0 m)
The M1196A / M1196AL compatible adult finger clip SpO2 sensor (SKU SS-024-AF30) is a reusable aftermarket replacement (not OEM) with a hard shell design and a 9.8 ft (3.0 m) cable, for use with the SpO2 technology shown in the table below.
| Sensor Type | Finger Clip (Hard Shell) |
| Patient Size | Adult |
| SpO2 Technology | Philips FAST |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Replaces | Philips M1196A, M1196AL |
Works with: the monitor models listed in the Specifications tab. Browse more SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for patient monitors and SpO2 sensors. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SS-024-AF30 |
| Replaces OEM Part | Philips M1196A, M1196AL |
| Category | Cables & Sensors > SpO2 |
| Sensor Type | Finger Clip (Hard Shell) |
| Patient Size | Adult |
| SpO2 Technology | Philips FAST |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Goldway | G30, G40 |
| Mindray / Datascope | V12 |
| Philips | 862108, 862231, 862439, 862472, 862474 C3, 863063 VM4, 863064, 863065, 863066, 863068, 863071, 863071 VS3, 863072, 863073, 863074, 863077, 863080, 863081, 863082, 863085, 863086, 863087, 863088, 863264, 863265, 863266, 863276, 863278, 865240, 865241, 865242, 866060, 866061, 866062, 866064, 866066, Agilent Series 50XM, Avalon FM20, Avalon FM30, Avalon FM40, Avalon FM50, C1, C3, Codemaster 100, HeartStart 4000, HeartStart MPx, HeartStart MRx, HeartStart XL, HeartStart XLT, Heartstream XL, IntelliVue MP5, IntelliVue MP5SC, IntelliVue MP5T, IntelliVue MP20, IntelliVue MP20 Junior, IntelliVue MP30, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MP80, IntelliVue MP90, IntelliVue MX100, IntelliVue MX400, IntelliVue MX430, IntelliVue MX450, IntelliVue MX500, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX750, IntelliVue MX800, IntelliVue TRx4841A, IntelliVue X2, IntelliVue X3, IntelliVue XG50, M3, M4, M1020A, M1020B, M1350A, M1350C, M2475B, M2601A, M2601B, M2702A, M2703A, M2704A, M2705A, M3000A, M3001A, M3001A A01, M3001A A01C06, M3001A A01C12, M3001A A01C18, M3002A MMS X2, M3002A Opt. C12, M3046A (M4 chip), M3046A M3, M3500B, M3535A, M3536A, M3536M, M4735A, M4841A, M5500B, M8001A, M8002A, M8003A, M8004A, M8005A, M8007A, M8008A, M8010A, M8102A, M8102A MP2, M8102A Opt.C12 MP2, M8105A, M8105A MP5, M8105A Opt. C12 MP5, M8105AS, M8105AT, MX4841A, MX Series, P60E, SureSigns VM1, SureSigns VM4, SureSigns VM6, SureSigns VM8, SureSigns VS2, SureSigns VS2+, SureSigns VS3, SureSigns VS4, SureSigns VSi, TRx 4851A, TRx M4841A, TRx+ M4841A, Viridia 24C, Viridia 50 XMO |
| Solaris | NT2A, NT2C |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Philips | M1196A, M1196AL, 989803128631, 989803205901 |
| Beta Biomed | B505-1006V-10 |
| Praymed | PSA0015-L |
| Sage | P01-30M |
| Unimed | U410N-91, U410-91 |
IPR Medical buys, sells, repairs, and stocks parts for finger clip SpO2 sensors and the monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, FAST, IntelliVue, SureSigns, HeartStart, Heartstream, Avalon, Viridia, Codemaster, TRx, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the M1196A / M1196AL Compatible Adult Finger Clip SpO2 Sensor?
The IPR Medical SS-024-AF30 is a compatible aftermarket (not OEM) adult finger clip SpO2 sensor that replaces OEM parts M1196A and M1196AL. A hard shell clip sits at the end of a 9.8 ft (3.0 m) cable, and the SpO2 technology the sensor is intended for appears in the Specifications table. With cleaning and a check between patients, this reusable sensor can be returned to service again and again.
Compatible Monitor Models
Use the Compatible Monitor Models table on the Specifications tab to confirm your monitor; it lists the original equipment manufacturer’s models individually, by name or product number. You will also see the Mindray / Datascope V12 there, along with select Solaris models (NT2A and NT2C). If your model is not in the table, contact us before ordering.
Design and Construction
The SS-024-AF30 is sized for adult patients, with a hard shell finger clip and a cable that measures 9.8 ft (3.0 m), and it comes bagged on its own. Wipe down the clip and cable between patients per facility protocol, and make sure the clip closes fully and the cable is free of damage before each use.
When to Replace Your Adult Finger Clip SpO2 Sensor
Begin with the clip itself: cracks in the hard shell, or a clip that no longer closes firmly on the finger, mean the sensor should be replaced. Move on to the cable and connector, where a split or crushed jacket or bent pins are equally clear signs. At the monitor, saturation values that jump or vanish and a pulse value out of step with the patient point the same way; if a second sensor that is known to work reads normally on that monitor, retire the first one.
Cross Reference and Interchange Part Numbers
Besides replacing OEM parts M1196A and M1196AL, the sensor is listed against OEM numbers 989803128631 and 989803205901. The Specifications tab carries the complete Cross Reference / Interchange Part Numbers table, organized by manufacturer.
Why Source Finger Clip SpO2 Sensors from IPR Medical?
Sensor faults and monitor faults can look alike at the bedside. Repairs at IPR Medical are carried out in-house by our technicians, and our trade is buying, selling, repairing, and stocking parts for patient monitoring equipment and infusion pumps as an ISO 9001:2015-certified independent service organization. Call 855-477-8866 or explore our SpO2 sensors and cables to find the sensor you need.
IPR Medical buys, sells, repairs, and stocks parts for finger clip SpO2 sensors and the monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, FAST, IntelliVue, SureSigns, HeartStart, Heartstream, Avalon, Viridia, Codemaster, TRx, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.