Philips M1976A Compatible 5-Lead ECG Leadwire, Chest Lead, Grabber/Pinch, AHA, Molded, 3.0 ft (0.9 m)
The M1976A compatible 5-lead chest ECG leadwire (SKU EL-PHV5-90G-A) is a reusable aftermarket replacement (not OEM) with grabber/pinch ends on all five chest leads, AHA color coding, a molded distal connector, and a 3.0 ft (0.9 m) length.
| Lead Count | 5-Lead |
| Lead Placement | Chest Lead |
| Electrode End | Grabber/Pinch |
| Lead Type | Philips IntelliVue |
| Cable Length | 3.0 ft (0.9 m) |
| Lifecycle | Reusable |
| Replaces | Philips M1976A |
Works with: the monitor models listed in the Specifications tab. Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment and ECG accessories. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | EL-PHV5-90G-A |
| Replaces OEM Part | Philips M1976A |
| Category | Cables & Sensors > ECG/EKG |
| Product | ECG Leadwire |
| Lead Count | 5-Lead |
| Lead Placement | Chest Lead |
| Electrode End | Grabber/Pinch |
| AHA/IEC Code | AHA |
| Distal Connector | Molded |
| Feature | Shielded |
| Lead Type | Philips IntelliVue |
| Cable Length | 3.0 ft (0.9 m) |
| Intended Use | Monitoring |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Bexen Cardio | Reanibex 700 |
| Biolight | M7000, M8500, M9500, Q Series |
| Invivo | 101, 360SL, 450SL, 521A, Escort 100, Escort 101, Escort 102, Escort 200, Escort 300, PortaPak 80, PortaPak 90, PortaPak 1000, Prism |
| Ivy Biomedical | 101, 7800, Cardiac Trigger Monitor 3150 |
| Newtech | NT3A |
| Nihon Kohden | BSM-8301A, BSM-8302A, BSM-8500A, BSM-8502A, NT3B, OEC-6102A (s/n>20156), OEC-6105A (s/n>20226), OEC-7102A, OEC-8108A, TEC-5200A (s/n>20421), TEC-7100A, TEC-7200A, TEC-7300A |
| PaceTech | MiniMax 4000CL, Minipack 300, Minipack 3000, Minipack 3100, Vitalmax 800 Plus, Vitalmax 2100, Vitalmax 2200, Vitalmax 4000, Vitalmax 4000 Modular, Vitalmax 4000CL, Vitalmax 4100, Vitalmax 4100CL |
| Philips | 43100A, 43110A, 43120A, 78352C, 78354C, 78834C, 862474 C3, 867036, Affiniti 30, Affiniti 50, Affiniti 70, Affiniti CVx, Agilent 50XM, CX50, Envisor, EPIQ 7, HD15, HeartStart MRx, IE33, IntelliVue MP20, IntelliVue MP30, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MX500, IntelliVue MX750, IntelliVue MX800, IntelliVue MX850, M2, M3, M4, M1001A, M1002A, M1165A, M1166A, M1167A, M1175A, M1177A, M1204A, M1205A, M1264A, M1275A Transport, M1276A, M1280A, M1722A, M1722B, M1723A, M1723B, M2475B, M2601A, M3000A, M3001A, M3046A, M4735A, MMS X2, SureSigns VM6, SureSigns VM8, V24E, VM4, VM6, VM8 |
| Physio-Control | Lifepak 6, VSM-1ESF |
| Solaris | NT3C, NT3E, NT3F |
| Spacelabs | 400, 500, 600, 900, 90300, 90303B, 90308, 90408, 90425, 90428, 90431, 90432, 90470, 90600, 90700, 90701, 90721, 90724, PC Bedside, PCMS, TEK-208, TEK-408, TEK-413, TEK-414, TEK-511, TEK-512, TEK-514, TEK-5214045 |
| Welch Allyn | 242, Propaq Encore 206EL |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Philips | M1976A, 989803125881 |
| Curbell | LW-05BV-29AS-0000 |
| Sage | L01V-05-29P |
| Unimed | HPB5-90P |
IPR Medical buys, sells, repairs, and stocks parts for grabber ECG leadwires and the monitoring equipment they serve. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, IntelliVue, HeartStart, SureSigns, Affiniti, EPIQ, Envisor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the M1976A Compatible 5-Lead ECG Leadwire?
The IPR Medical EL-PHV5-90G-A is a compatible aftermarket (not OEM) 5-lead ECG leadwire that replaces OEM part M1976A. Its five chest leads terminate in grabber/pinch electrode ends and follow AHA color coding, and the leadwire measures 3.0 ft (0.9 m). Clinical teams can reuse it from one patient to the next, and it is intended for ECG monitoring.
Compatible Monitor Models
Equipment from a number of manufacturers appears on the compatibility list for the EL-PHV5-90G-A. Examples include select Nihon Kohden models such as the BSM-8500A and OEC-7102A, select Spacelabs models such as the 90425 and TEK-408, and select Biolight models such as the M8500. You will also find select PaceTech models, among them the Vitalmax 4100, and select Welch Allyn models including the 242. The complete list, with the remaining brands, is in the Compatible Monitor Models table on the Specifications tab, so please check your model there before you order.
Design and Construction
Grabber/pinch ends on all five chest leads connect the leadwire to the electrodes, and AHA color coding identifies each lead. A molded distal connector finishes the shielded 3.0 ft (0.9 m) leadwire. Before ordering, compare the lead type in the Specifications table with your existing leadwire. The leadwire is reusable and can be cleaned per facility protocol between patients; it is packaged one per bag.
When to Replace Your Grabber 5-Lead Chest ECG Leadwire
A grabber that no longer closes firmly on the electrode is one of the most common reasons to retire this leadwire. Cracked or stiffened insulation, kinks along a lead, bent pins, and a chipped or loose connector housing are others. On the monitor, watch for frequent lead-off messages on the chest channels, a drifting or noisy baseline, and artifact that tracks with cable movement. If those symptoms persist, swap in a known-good leadwire to rule the monitor in or out.
Cross Reference and Interchange Part Numbers
This compatible leadwire interchanges with OEM part M1976A and OEM number 989803125881. For the other interchange numbers, see the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source ECG Leadwires from IPR Medical?
Biomedical teams work with IPR Medical because we buy, sell, repair, and stock parts for patient monitoring equipment and infusion pumps, and we do it as an ISO 9001:2015-certified independent service organization. Monitor repairs are performed in-house by our technicians, who can help you confirm the right grabber leadwire for the monitors on your floor. See more ECG cables and leadwires or call 855-477-8866 for orders, repairs, or parts.
IPR Medical buys, sells, repairs, and stocks parts for grabber ECG leadwires and the monitoring equipment they serve. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, IntelliVue, HeartStart, SureSigns, Affiniti, EPIQ, Envisor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.


















