IPR Medical

Philips 989803143181 Compatible 3-Lead One-Piece ECG Cable, Grabber/Pinch, AHA, Defib-Proof, 8.2 ft + 3.0 ft (2.5 m + 0.9 m)

$60.00

The 989803143181 compatible 3-lead one-piece ECG cable (SKU EC-3005RG-A) is a reusable aftermarket replacement (not OEM) with grabber/pinch electrode ends, limb lead placement, AHA color coding, a defib-proof feature, and an 8.2 ft + 3.0 ft (2.5 m + 0.9 m) length, intended for monitoring.

Lead Count 3-Lead
Electrode End Grabber/Pinch
AHA/IEC Code AHA
Feature Defib-Proof (with Resist)
Cable Length 8.2 ft + 3.0 ft (2.5 m + 0.9 m)
Replaces Philips 989803143181

Works with: the monitor models listed in the Specifications tab. Browse more ECG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for patient monitors and ECG accessories. Call 855-477-8866 or email cs@iprmed.com.

SKU: EC-3005RG-A Categories: , Tags: ,
Send In Philips 989803143181 Compatible 3-Lead One-Piece ECG Cable, Grabber/Pinch, AHA, Defib-Proof, 8.2 ft + 3.0 ft (2.5 m + 0.9 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) EC-3005RG-A
Replaces OEM Part Philips 989803143181
Category Cables & Sensors > ECG/EKG
Product One-Piece ECG Cable
Lead Count 3-Lead
Lead Placement Limb Lead
Electrode End Grabber/Pinch
AHA/IEC Code AHA
Feature Defib-Proof (with Resist)
Cable Length 8.2 ft + 3.0 ft (2.5 m + 0.9 m)
Intended Use Monitoring
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Konsung Aurora 12s
Newtech NT3A
Nihon Kohden NT3B, Omnicare CMA
Philips 43100A, 43110A, 43120A, 78352C, 78354A/C, 78354C, 78534C, 78834A/B/C, 78834C, 862472, 862473, 862474, 862474 C3, 862475, 862475 C3, 862478, 862478 C3, 862479, 862479 C3, 863063 VM4, 863064, 863065, 863066, 863068, 863069, 863077, 865240, 865241, 865242, 866060, 866061, 866062, 866064, 866066, Agilent Series 50XM, C3, C Series, Codemaster XL, CX50, Efficia CM10 (863301), Efficia CM12 (863303), Efficia CM100 (863300), Efficia CM120 (863302), Efficia CM150 (863304), Envisor, EPIQ 7, HD15, HeartStart MRx, HeartStart XL, IE33, IntelliVue MP5, IntelliVue MP20, IntelliVue MP20 Junior, IntelliVue MP30, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MP80, IntelliVue MP90, IntelliVue MX100, IntelliVue MX400, IntelliVue MX430, IntelliVue MX450, IntelliVue MX500, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX700 Masimo Rainbow, IntelliVue MX800, IntelliVue TRx4841A, IntelliVue X2, IntelliVue X3, IntelliVue XG50, M2, M3, M4, M1001A, M1001B, M1002A, M1002B, M1094A, M1094B, M1165A, M1166A, M1167A, M1175A, M1177A, M1204A, M1205A, M1264A, M1275A, M1275A Transport, M1276A, M1280A, M1722A, M1722B, M1723A, M1723B, M2475B, M2601A, M2601B, M3000A, M3001A, M3001A Opt. C12, M3001A Opt. C18, M3002A, M3002A MMS X2, M3002A X2, M3046A, M3046A (M4 chip), M3046A M3, M3535A, M3536A, M4735A, M8001A, M8002A, M8003A, M8004A, M8005A, M8007A, M8008A, M8010A, M8102A MP2, M8105A MP5, Merlin, P60E, SureSigns VM3, SureSigns VM4, SureSigns VM6, SureSigns VM8, TRx4851A, V24, V24E, V26, Viridia 24, Viridia 24C
Smiths Medical / BCI SurgiVet V9200
Solaris NT3C, NT3E, NT3F
Welch Allyn 242, Propaq Encore 206EL

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Philips 989803143181, 989803160731, M1981A, M1970A
Comen 040-000914-00, A3105-EC1
Sage A01-03P
Unimed 2385P

IPR Medical buys, sells, repairs, and stocks parts for 3-lead ECG cables and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Masimo, or any other manufacturer or supplier named on this page. Philips, Masimo, IntelliVue, SureSigns, HeartStart, Efficia, EPIQ, Envisor, Viridia, CodeMaster, Merlin, TRx, Rainbow, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the 989803143181 Compatible 3-Lead One-Piece ECG Cable?

The IPR Medical EC-3005RG-A is a compatible aftermarket (not OEM) 3-lead one-piece ECG cable that replaces OEM part 989803143181. In a one-piece design the leads and the main cable form a single assembly, so there is no separate leadwire set to pair with it. This reusable cable is set up for limb lead monitoring, finishes each lead in a grabber/pinch electrode end, and is listed as defib-proof.


Compatible Monitor Models

The model list behind this cable is extensive, and most of it belongs to the original equipment manufacturer; those entries are shown in full in the Compatible Monitor Models table on the Specifications tab. Outside that group, the table names the Smiths Medical / BCI SurgiVet V9200 and the Konsung Aurora 12s, together with select Solaris, Welch Allyn, Newtech, and Nihon Kohden models such as the NT3C, Propaq Encore 206EL, NT3A, and NT3B. It is worth confirming your exact model there before you buy.


Design and Construction

The EC-3005RG-A carries three limb leads, and each one ends in a grabber/pinch connection that grips the electrode. Following the AHA color code, the leads are RA white, LA black, and LL red. Its length is specified as 8.2 ft + 3.0 ft (2.5 m + 0.9 m), and the cable has a defib-proof feature for monitoring use. Between patients, clean the cable as your facility protocol directs; it is reusable and comes packed one per bag.


When to Replace Your 3-Lead One-Piece ECG Cable

A grabber whose jaws no longer close firmly on the electrode is one of the clearest signs that this cable is due for replacement. Others include a jacket that is cracked, cut, or kinked anywhere along the main cable or the leads, bent pins or a damaged housing at the monitor connector, and lead-off alarms or noisy traces that come and go as the patient moves. Before ordering, biomedical staff can rule the monitor in or out by running the same patient setup through a second, known-good cable.


Cross Reference and Interchange Part Numbers

OEM part 989803143181 is the primary reference for the EC-3005RG-A. OEM numbers 989803160731, M1981A, and M1970A cross-reference to the same cable, and two Comen numbers, 040-000914-00 and A3105-EC1, are on record as well. Aftermarket equivalents round out the Cross Reference / Interchange Part Numbers table on the Specifications tab, where every number sits under its own brand.


Why Source One-Piece ECG Cables from IPR Medical?

Beyond ECG cables like this one, IPR Medical’s catalog and service work extend to buying, selling, repairing, and stocking parts for patient monitors and infusion pumps. An ISO 9001:2015-certified independent service organization, IPR Medical relies on its own in-house technicians for repairs. Browse our ECG cables and leadwires, or phone 855-477-8866 and a member of our team will help.

IPR Medical buys, sells, repairs, and stocks parts for 3-lead ECG cables and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Masimo, or any other manufacturer or supplier named on this page. Philips, Masimo, IntelliVue, SureSigns, HeartStart, Efficia, EPIQ, Envisor, Viridia, CodeMaster, Merlin, TRx, Rainbow, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.