IPR Medical

Philips 989803143201 Compatible 5-Lead One-Piece ECG Cable, Grabber/Pinch, AHA, Defib-Proof, 8.2 ft + 3.0 ft (2.5 m + 0.9 m)

$70.00

The 989803143201 compatible 5-lead one-piece ECG cable (SKU EC-5005RG-A) is a reusable aftermarket replacement (not OEM) with grabber/pinch electrode ends, limb and chest lead placement, AHA color coding, a defib-proof feature, and an 8.2 ft + 3.0 ft (2.5 m + 0.9 m) length, intended for monitoring.

Lead Count 5-Lead
Lead Placement Limb + Chest Lead
Electrode End Grabber/Pinch
Feature Defib-Proof (with Resist)
Cable Length 8.2 ft + 3.0 ft (2.5 m + 0.9 m)
Replaces Philips 989803143201

Works with: the monitor models listed in the Specifications tab. Browse more ECG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment and ECG cables. Call 855-477-8866 or email cs@iprmed.com.

SKU: EC-5005RG-A Categories: , Tags: ,
Send In Philips 989803143201 Compatible 5-Lead One-Piece ECG Cable, Grabber/Pinch, AHA, Defib-Proof, 8.2 ft + 3.0 ft (2.5 m + 0.9 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) EC-5005RG-A
Replaces OEM Part Philips 989803143201
Category Cables & Sensors > ECG/EKG
Product One-Piece ECG Cable
Lead Count 5-Lead
Lead Placement Limb + Chest Lead
Electrode End Grabber/Pinch
AHA/IEC Code AHA
Feature Defib-Proof (with Resist)
Cable Length 8.2 ft + 3.0 ft (2.5 m + 0.9 m)
Intended Use Monitoring
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Konsung Aurora 12s
Newtech NT3A
Nihon Kohden NT3B, Omnicare CMA
Philips 43100A, 43110A, 43120A, 78352C, 78354A/C, 78354C, 78355C, 78834A/B/C, 78834C, 860335, 862472, 862473, 862474, 862474 C3, 862475, 862475 C3, 862478, 862478 C3, 862479, 862479 C3, 863053, 863054 C1, 863064, 863065, 863066, 863066A, 863068, 865240, 865241, 865242, 866060, 866061, 866062, 866064, 866066, Agilent Series 50XM, C3, C Series, CX50, Efficia CM10 (863301), Efficia CM12 (863303), Efficia CM100 (863300), Efficia CM120 (863302), Efficia CM150 (863304), Envisor, EPIQ, HD15, HeartStart MRx, HeartStart XL, IE33, IntelliVue MP5, IntelliVue MP20, IntelliVue MP20 Junior, IntelliVue MP30, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MP80, IntelliVue MP90, IntelliVue MX100, IntelliVue MX400, IntelliVue MX430, IntelliVue MX450, IntelliVue MX500, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX700 Masimo Rainbow, IntelliVue MX800, IntelliVue TRx4841A, IntelliVue X2, IntelliVue X3, IntelliVue XG50, M2, M3, M4, M1001A, M1001B, M1002A, M1002B, M1094A, M1094B, M1165A, M1166A, M1167A, M1175A, M1177A, M1204A, M1205A, M1264A, M1275A, M1275A Transport, M1276A, M1280A, M1722A, M1722B, M1723A, M1723B, M1770A, M1771A, M1772A, M2475B, M2601A, M2601B, M2662A, M3000A, M3001A, M3001A Opt. C12, M3001A Opt. C18, M3002A, M3002A MMS X2, M3046A, M3046A (M4 chip), M3046A M3, M3535A, M3536A, M3536M, M3923A, M3924A, M3926A, M3927A A3, M3928A A3, M3929A, M4735A, M8001A, M8002A, M8003A, M8004A, M8005A, M8007A, M8008A, M8010A, M8102A, M8102A MP2, M8102A Opt.C12 MP2, M8105A, M8105A MP5, M41764A, M417645A, Merlin, P60E, SureSigns VM6, SureSigns VM8, TRx4851A, V24, V24E, V26, Viridia 24, Viridia 24C, VM4
Solaris NT3C, NT3E, NT3F
Welch Allyn 242, Propaq Encore 206EL

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Philips 989803143201, M1975A, M1986A, 989803160771
Comen 040-000915-00, A5105-EC1
Unimed 2585P

IPR Medical buys, sells, repairs, and stocks parts for 5-lead ECG cables and the monitoring equipment they serve. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Masimo, or any other manufacturer or supplier named on this page. Philips, Masimo, IntelliVue, SureSigns, HeartStart, Efficia, EPIQ, Envisor, Viridia, Merlin, TRx, Rainbow, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the 989803143201 Compatible 5-Lead One-Piece ECG Cable?

The IPR Medical EC-5005RG-A is a compatible aftermarket (not OEM) 5-lead one-piece ECG cable that replaces OEM part 989803143201. Set up for limb and chest lead placement, it has five leads that terminate in grabber/pinch electrode ends, and it is listed as defib-proof. As a one-piece design, the leads are part of the cable rather than a separate leadwire set, and the whole reusable assembly is intended for ECG monitoring.


Compatible Monitor Models

For OEM part 989803143201, the compatibility list is long, and nearly all of it is made up of the original equipment manufacturer’s models; the Compatible Monitor Models table on the Specifications tab lists every one. Among the other brands are select Solaris models such as the NT3C, NT3E, and NT3F, select Welch Allyn models such as the Propaq Encore 206EL, and select Nihon Kohden, Newtech, and Konsung models (the NT3B, NT3A, and Aurora 12s). Please make sure your model is on that list before ordering.


Design and Construction

Five leads cover limb and chest placement on the EC-5005RG-A, each finished with a grabber/pinch end. Under AHA color coding, RA is white, LA black, LL red, RL green, and V brown. The cable is specified at 8.2 ft + 3.0 ft (2.5 m + 0.9 m), carries a defib-proof feature, and is reusable, so it can go back into service after cleaning per your facility protocol. Each cable comes one per bag.


When to Replace Your 5-Lead One-Piece ECG Cable

With five leads in play, a worn cable often shows up as one lead that keeps dropping out while the others read normally, or as artifact that changes when the chest lead is moved. Physically, look for grabbers that have lost their tension, cracks or kinks in the jacket of the main cable or any lead, and bent pins or a cracked housing at the monitor connector. Try a known-good cable on the same monitor to confirm that the cable is the cause before you replace it.


Cross Reference and Interchange Part Numbers

Besides OEM part 989803143201, this cable cross-references to OEM numbers M1975A, M1986A, and 989803160771, along with Comen numbers 040-000915-00 and A5105-EC1. One aftermarket number also matches this cable; the Specifications tab lists it by brand under Cross Reference / Interchange Part Numbers.


Why Source One-Piece ECG Cables from IPR Medical?

For patient monitoring equipment and infusion pumps, IPR Medical handles four things: buying, selling, repairing, and stocking parts. Repairs are completed in-house by the company’s technicians, and its ISO 9001:2015 certification was earned as an independent service organization. Call 855-477-8866 for help choosing a replacement cable or scheduling a repair, or browse our ECG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for 5-lead ECG cables and the monitoring equipment they serve. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, Masimo, or any other manufacturer or supplier named on this page. Philips, Masimo, IntelliVue, SureSigns, HeartStart, Efficia, EPIQ, Envisor, Viridia, Merlin, TRx, Rainbow, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.