GE Healthcare 411203-001 Compatible 3-Lead Multi-Link ECG Leadwire, Snap, Molded, 3 ft (0.9 m), AHA
The GE Healthcare 411203-001 compatible 3-lead ECG leadwire is a reusable, aftermarket replacement (not OEM) for GE’s Multi-Link 3-lead snap set, built to match the original’s fit, form, and function.
| Leads | 3 (RA, LA, LL) |
| Trunk-End Connector | GE Multi-Link, Molded |
| Patient-End Connector | Snap |
| Lead Length | 3 ft (0.9 m) |
| Color Code | AHA (US) |
| Patient Size | Adult/Pediatric |
| Construction | Shielded, Reusable, Latex-Free |
Works with: GE CARESCAPE B105, B125, B450, B650, B850, and ONE; Dash 3000, 4000, and 5000; Solar 8000 and 9500; Tram modules; ApexPro CH; Datex-Ohmeda Aestiva/5 and Unity; and more. See the Specifications tab for the full list. Browse more ECG/EKG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Replacement (Aftermarket, Not OEM) |
| IPR Medical SKU | EL-MQ3-90S-A |
| OEM Reference | GE Healthcare 411203-001 |
| Lead Type | GE Multi-Link |
| Lead Count | 3 Leads |
| Lead Placement | Limb Leads (RA, LA, LL) |
| Color Code | AHA (US): RA White, LA Black, LL Red |
| Trunk-End Connector | GE Multi-Link, Molded |
| Patient-End Connector | Snap (Grouped) |
| Leadwire Length | 3 ft (0.9 m) |
| Shielding | Shielded |
| Cable Jacket | TPU, Gray |
| Cable Diameter | 0.10 in (2.6 mm) |
| Patient Size | Adult/Pediatric |
| Lifecycle | Reusable |
| Latex-Free | Yes |
| Sterile | No |
| Packaging | 1 per Bag |
| Weight | 0.3 lbs |
Compatible Equipment Models
| Manufacturer | Compatible Models |
| GE Healthcare | CARESCAPE B105, B125, B450, B650, B850, CARESCAPE ONE; Procare B40; ApexPro CH; Aisys CS2 |
| GE Healthcare (Imaging) | Logiq 5, Logiq 7, Logiq E9; Vivid 7, Vivid e9, Vivid i, Vivid S5, Vivid S6, Vivid S70N, Vivid E80, Vivid E90, Vivid E95 |
| GE Healthcare / Marquette | Dash 1000, 2000, 2500, 3000, 4000, 5000; Dash PRO 2000, 3000, 4000 |
| GE Healthcare / Marquette | Solar 3000, 8000, 9500; Eagle, Eagle Systems; Responder 2000, 3000 |
| GE Healthcare / Marquette | Tram 100, 200, 300, 400, 451, 500, 600, 800; PDM Module; MAC-Lab; Unity Systems |
| GE Healthcare / Corometrics | 120, 250cx, 259cx |
| Datex-Ohmeda | Aestiva/5, E-PRESTN, M-PRESTN, Unity |
| Draeger | Narkomed 6400 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| GE Healthcare | 411203-001, 411203-002 |
| GE Healthcare | 2106385-001, 2106385-002 (Individually Replaceable) |
| AMC | LW-2410029/3A, LW-2410051/3A |
| Curbell | LDW-03AW-29AM-0000, LDW-03AW-51AM-0000, RLW-03AW-29AS-0000 |
| Elite Biomedical | 91015 EBS |
| Pacific Medical | NLMQ5232 |
| RPI | LKM052 |
| Sage Services Group | L02-03-29S |
| Schiller | 55.065103 |
IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE, Dash, and Solar patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, or any other manufacturer or supplier named on this page. GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the GE 411203-001 Compatible 3-Lead Snap Leadwire?
The GE Healthcare 411203-001 compatible 3-lead ECG leadwire is a reusable, aftermarket snap-end lead set for GE’s Multi-Link ECG system. Three limb leads (RA, LA, and LL) carry signals from snap electrodes to a Multi-Link trunk cable. That gives basic heart rate and rhythm monitoring, the standard setup in pre-op and PACU, procedural sedation, transport, and general med-surg monitoring. It is a compatible replacement, not an original GE part, and it is built to the same fit, form, and function as the OEM 411203-001 lead set.
Compatible Equipment Models
Using the GE Multi-Link connector, this compatible 3-lead snap set fits a broad range of GE and related equipment. That includes CARESCAPE B105, B125, B450, B650, B850, and CARESCAPE ONE monitors, the Procare B40, Dash 1000 through Dash 5000 and Dash PRO monitors, Solar 3000, 8000, and 9500 systems, Tram and PDM modules, ApexPro CH telemetry, Eagle and Responder monitors, MAC-Lab, and Unity Systems. It also fits the Aisys CS2 anesthesia system, Logiq and Vivid ultrasound systems, the Corometrics 120, 250cx, and 259cx, Datex-Ohmeda Aestiva/5, E-PRESTN, M-PRESTN, and Unity equipment, and the Draeger Narkomed 6400. The trunk cable in service must accept a 3-lead set.
Design and Construction
The three shielded leads are each 3 ft (0.9 m) long and end in snap connectors that press onto standard snap electrodes for a flat, secure attachment. At the trunk end, a molded Multi-Link connector locks into the GE trunk cable. The leads follow the AHA color code: white for right arm, black for left arm, and red for left leg. The gray TPU jacket is about 0.10 in (2.6 mm) in diameter and resists tangling and repeated cleaning. The set is latex-free, non-sterile, rated for adult and pediatric patients, weighs about 0.3 lbs, and ships one per bag.
When to Replace Your GE Multi-Link 3-Lead Snap Leadwire
In high-throughput areas like PACU and pre-op, 3-lead sets are connected and disconnected many times a day, so they wear quickly. Replace the set when snaps release from electrodes easily, when the ECG trace is noisy or drops out even with fresh electrodes, when the Multi-Link connector no longer clicks securely into the trunk cable, or when you see cracked jacketing, exposed shielding, or faded color bands. Keeping spares on hand avoids delays at the start of a case.
Cross Reference and Interchange Part Numbers
This compatible 3-lead snap leadwire, IPR Medical SKU EL-MQ3-90S-A, cross-references to GE Healthcare part numbers 411203-001, 411203-002, 2106385-001, and 2106385-002. It also interchanges with AMC LW-2410029/3A and LW-2410051/3A; Curbell LDW-03AW-29AM-0000, LDW-03AW-51AM-0000, and RLW-03AW-29AS-0000; Elite Biomedical 91015 EBS; Pacific Medical NLMQ5232; RPI LKM052; Sage Services Group L02-03-29S; and Schiller 55.065103. Some of these numbers are the same lead set in a different length (the OEM 411203-001 is 29 in and 411203-002 is 51 in), so confirm the 3 ft (0.9 m) length suits your application.
Why Source ECG Leadwires from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. Our GE Multi-Link-compatible lead sets come in 3-, 5-, and 6-lead configurations with snap and grabber ends, so each care area can stock the right set at lower cost than OEM. Our team can help match lead sets to your trunk cables and support your CARESCAPE, Dash, and Solar monitors with in-house repair services.
IPR Medical buys, sells, repairs, and stocks parts for GE CARESCAPE, Dash, and Solar patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, or any other manufacturer or supplier named on this page. GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.