GE Healthcare 2021197-001 Compatible IBP Adapter Cable for Edwards Transducers, 11-Pin, 13 ft (4.0 m)
The GE Healthcare 2021197-001 compatible IBP adapter cable (SKU IBP-MQ-EW40) is a reusable, aftermarket replacement (not OEM) that connects Edwards disposable pressure transducers to GE monitors with the flat 11-pin IBP input, built to match the original’s fit, form, and function.
| Cable Type | IBP Adapter / Interface Cable |
| Transducer Compatibility | Edwards Disposable Pressure Transducers |
| Monitor-End Connector | Flat 11-Pin, Dual-Keyed GE |
| Transducer-End Connector | Edwards |
| Cable Length | 13 ft (4.0 m) |
| Construction | Gray, Reusable, Latex-Free |
Works with: GE Dash 1000–5000, Solar 7000/8000/9000, Eagle, Tram and Tram-Rac modules, PDM and CARESCAPE PDM, Procare B40, Cath-Lab and MAC-Lab, Datex-Ohmeda E-PRESTN, and Draeger Narkomed 6400. See the Specifications tab for the full list. Browse more IBP cables and accessories.
IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Replacement (Aftermarket, Not OEM) |
| IPR Medical SKU | IBP-MQ-EW40 |
| OEM Reference | GE Healthcare 2021197-001 |
| Cable Type | IBP Adapter / Interface Cable |
| Transducer Compatibility | Edwards Disposable Pressure Transducers |
| Monitor-End Connector | Flat 11-Pin, Dual-Keyed GE Connector |
| Transducer-End Connector | Edwards |
| Cable Length | 13 ft (4.0 m) |
| Cable Color | Gray |
| Cable Diameter | 0.16 in (4 mm) |
| Lifecycle | Reusable |
| Latex-Free | Yes |
| Sterile | No |
| Packaging | 1 per Bag |
| Weight | 0.6 lbs |
Compatible Equipment Models
| Manufacturer | Compatible Models |
| GE Healthcare / Marquette | Dash 1000, 2000, 3000, 3100, 4000, 5000 |
| GE Healthcare / Marquette | Solar 7000, 8000, 9000; Eagle |
| GE Healthcare / Marquette | Tram 451; Tram Module 100–600; Tram-Rac 3, Tram-Rac 4A; Tram Scope 100–800 A, Tram Scope 100–800 L |
| GE Healthcare / Marquette | PDM Module; Cath-Lab; MAC-Lab |
| GE Healthcare | CARESCAPE PDM; Procare B40 |
| Datex-Ohmeda | E-PRESTN |
| Draeger | Narkomed 6400 |
| Contec | MS400 Patient Simulator |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| GE Healthcare | 2021197-001 |
| Marquette | 2021197-002 (OEM is 1.2 m) |
| Marquette | 2104162-001, 2104162-002 |
| Edwards | 896507-001, 896507021 |
| AMC | CB-91021E |
| Sage Services Group | B02-ED-40M |
IPR Medical buys, sells, repairs, and stocks parts for GE Dash, Solar, and Tram patient monitoring systems. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Edwards, GE Healthcare, or any other manufacturer or supplier named on this page. Edwards, GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the GE 2021197-001 Compatible IBP Adapter Cable?
The GE Healthcare 2021197-001 compatible IBP adapter cable is a reusable, aftermarket interface cable that connects an Edwards disposable pressure transducer to a GE invasive blood pressure (IBP) input. During arterial, central venous, or pulmonary artery pressure monitoring, the transducer converts fluid-line pressure into an electrical signal. This cable carries that signal to the monitor, which displays waveforms and systolic, diastolic, and mean values in mmHg. Because the transducer is disposable and the adapter cable is reusable, facilities replace only the transducer between patients. It is a compatible replacement, not an original GE part, and it is built to the same fit, form, and function as the OEM 2021197-001 cable.
Compatible Equipment Models
This compatible adapter cable is confirmed for use with GE Marquette Dash 1000, 2000, 3000, 3100, 4000, and 5000 monitors, Solar 7000, 8000, and 9000 systems, Tram 451 and Tram modules 100 through 600, Tram-Rac 3 and 4A housings, Tram Scope 100 through 800 (A and L), the PDM module and CARESCAPE PDM, Eagle monitors, and the Cath-Lab and MAC-Lab recording systems. It also works with the GE Procare B40, Datex-Ohmeda E-PRESTN, and Draeger Narkomed 6400, and with the Contec MS400 patient simulator for IBP channel testing. The cable is designed for Edwards transducers. Facilities using Argon, B. Braun, BD, Utah, or Medex transducers need a different adapter.
Design and Construction
The cable runs 13 ft (4.0 m), giving enough reach from a bedside or boom-mounted monitor to a transducer on an IV pole or patient-side mount in ICU, OR, and cath lab settings. The monitor end has a flat, dual-keyed 11-pin GE connector that seats in the IBP port in only one orientation. The transducer end has an Edwards-style connector that mates with Edwards disposable pressure transducers. The gray jacket is about 0.16 in (4 mm) in diameter and stays flexible through routine cleaning. The cable is latex-free, non-sterile, weighs about 0.6 lbs, and ships one per bag.
When to Replace Your GE IBP Adapter Cable
IBP adapter cables are exposed to saline, blood, and cleaning agents, and they flex constantly at both connectors. Replace the cable when the monitor won’t zero or reports a transducer or cable fault with a known-good transducer, when the waveform drifts, dampens, or drops out as the cable is moved, or when readings don’t match a reference check. Also replace it if you find corrosion or fluid residue in the Edwards connector, bent or recessed pins on the 11-pin connector, a loose connector latch, or a cracked jacket. Testing with a pressure simulator and a second cable quickly isolates the fault.
Cross Reference and Interchange Part Numbers
This compatible IBP adapter cable, IPR Medical SKU IBP-MQ-EW40, cross-references to GE Healthcare part number 2021197-001, to Marquette part numbers 2021197-002, 2104162-001, and 2104162-002, and to Edwards part numbers 896507-001 and 896507021. It also interchanges with AMC CB-91021E and Sage Services Group B02-ED-40M. Some of these references differ in length (the OEM 2021197-002, for example, is 1.2 m), so confirm the 13 ft (4.0 m) length suits your setup.
Why Source IBP Cables from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. Our compatible IBP adapter cables give critical care and biomedical teams an affordable alternative to OEM parts while matching OEM fit and function across GE Dash, Solar, and Tram fleets. Our team can help match the right adapter to your transducer brand and support your monitors and modules with in-house repair services.
IPR Medical buys, sells, repairs, and stocks parts for GE Dash, Solar, and Tram patient monitoring systems. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Edwards, GE Healthcare, or any other manufacturer or supplier named on this page. Edwards, GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.