IPR Medical

GE Healthcare Marquette 2016995-001 Compatible IBP Adapter Cable for BD Transducers, Reusable, 13.1 ft (4.0 m)

$75.00

The GE IBP adapter cable 2016995-001 compatible replacement is a reusable, aftermarket cable (not OEM) that connects BD pressure transducers to GE Marquette monitors and Tram modules, built to OEM fit, form, and function.

Transducer Compatibility BD
Cable Length 13.1 ft (4.0 m)
Lifecycle Reusable

Works with: Marquette Dash 1000–5000, Solar 7000/8000/9000, Eagle, Tram 451 and Tram 100–600 modules, Tramscope, PDM, GE B40, Cath-Lab and MAC-Lab, Datex-Ohmeda E-PRESTN, and Draeger Narkomed 6400. See the Specifications tab for the full list. Browse more IBP cables and adapters.

IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: IBP-MQ-BD40 Categories: , Tags: , ,
Send In GE Healthcare Marquette 2016995-001 Compatible IBP Adapter Cable for BD Transducers, Reusable, 13.1 ft (4.0 m) for Repair
Product Type Compatible Replacement (Aftermarket, Not OEM)
IPR Medical SKU IBP-MQ-BD40
OEM Reference GE Healthcare 2016995-001
IBP Cable Type Adapter Cable
Transducer Compatibility BD
Cable Length 13.1 ft (4.0 m)
Lifecycle Reusable
Packaging 1 per Bag

Compatible Monitor Models

For use with BD pressure transducers only.

Manufacturer / Series Compatible Models
GE Healthcare / Marquette Dash 1000, 2000, 3000, 3100, 4000, 5000; Eagle
GE Healthcare / Marquette Solar 7000, 8000, 9000; Cath-Lab; MAC-Lab
GE Healthcare / Marquette Tram Tram 451; Tram Module 100–600; Tram-Rac 3, 4A; Tram PKG; Tramscope 100–800 A, 100–800 L; PDM Module
GE Healthcare B40
Datex-Ohmeda E-PRESTN Module
Draeger Narkomed 6400
Test Equipment Contec MS400 Patient Simulator; Pronk Technologies SL-8

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
GE Healthcare / Marquette 2016995-001, 2016995-002
GE Healthcare / Marquette 700077-001
BD (Alaris) 684102
Unimed BC-MQ-BD

IPR Medical buys, sells, repairs, and stocks parts for GE Dash, Solar, Eagle, and Tram patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by BD, GE Healthcare, Marquette, or any other manufacturer or supplier named on this page. BD, GE Healthcare, Marquette, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the GE 2016995-001 Compatible IBP Adapter Cable?

The GE Healthcare Marquette 2016995-001 compatible IBP adapter cable is a reusable, aftermarket interface cable that connects BD disposable pressure transducers to the invasive blood pressure input on GE Marquette patient monitors and modules. It carries the transducer signal for arterial, central venous, pulmonary artery, and other invasive pressure monitoring. It is a compatible replacement, not an original GE part, and it is built to OEM fit, form, and function.


Compatible Monitor Models

This compatible adapter cable is confirmed for use with Marquette Dash 1000, 2000, 3000, 3100, 4000, and 5000 monitors, Solar 7000, 8000, and 9000 systems, Eagle monitors, the GE B40, and Cath-Lab and MAC-Lab hemodynamic systems. It fits Tram 451 and Tram 100 through 600 modules, Tram-Rac 3 and 4A housings, Tram PKG, Tramscope 100 through 800 A and L models, and the PDM module. It also fits the Datex-Ohmeda E-PRESTN module and the Draeger Narkomed 6400 anesthesia system, and it can be used with the Contec MS400 and Pronk Technologies SL-8 patient simulators for IBP channel testing. The cable is for BD transducers only; other transducer brands require a matching adapter cable.


Design and Construction

The 13.1 ft (4.0 m) cable provides reach from the monitor or Tram module to a transducer mounted on an IV pole or patient-side manifold in the ICU, OR, and cath lab. The patient end mates with BD disposable transducers, and the monitor end connects to the GE Marquette IBP input. The cable is reusable after cleaning according to facility protocol and ships one per bag.


When to Replace Your GE IBP Adapter Cable

Replace the adapter cable when the monitor will not zero or shows “transducer disconnected” or “no transducer” with a known-good transducer, when the pressure waveform is noisy, drifts, or drops out as the cable is moved, or when you find a cracked jacket, a loose transducer connector, or bent or corroded pins. Checking the channel with an IBP simulator or a known-good transducer quickly shows whether the cable, transducer, or monitor input is at fault.


Cross Reference and Interchange Part Numbers

This compatible BD IBP adapter cable, IPR Medical SKU IBP-MQ-BD40, cross-references to GE Healthcare / Marquette part numbers 2016995-001, 2016995-002, and 700077-001, and to BD (Alaris) 684102. It also interchanges with Unimed BC-MQ-BD. For Edwards, Utah, Abbott/Medex, B. Braun, Argon, and other transducer brands, contact IPR Medical for the matching GE-compatible IBP adapter cable.


Why Source IBP Cables from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. We carry compatible IBP adapter cables for the major transducer brands alongside ECG, SpO2, NIBP, and temperature accessories for GE Marquette and CARESCAPE monitors, so biomedical teams can supply their fleet from one source at lower cost than OEM. Our team can help match the right adapter to each transducer and monitor and support your GE equipment with in-house repair services.

IPR Medical buys, sells, repairs, and stocks parts for GE Dash, Solar, Eagle, and Tram patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by BD, GE Healthcare, Marquette, or any other manufacturer or supplier named on this page. BD, GE Healthcare, Marquette, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.