Mindray 0012-00-1262-01 Compatible 5-Lead ECG Leadwire Set, AHA, Grabber/Pinch, Shielded, 3 ft (0.9 m)
The Mindray 0012-00-1262-01 compatible 5-lead ECG leadwire set (SKU EL-MR5-90G-A) is a reusable, aftermarket replacement (not OEM). It has shielded limb and chest leads, grabber (pinch) ends, and AHA color coding, and it connects to a Mindray or Datascope 3/5-lead ECG trunk cable.
| Lead Count | 5-Lead (Limb and Chest Leads) |
| Standard | AHA (RA White, LA Black, RL Green, LL Red, V Brown) |
| Electrode Ends | Grabber / Pinch |
| Lead Length | 3 ft (0.9 m), Shielded |
| Lifecycle | Reusable, Latex-Free |
| Replaces | Mindray / Datascope 0012-00-1262-01, 0012-00-1262-02, 0012-00-1262-03, 0010-30-42727, and more |
Works with: Mindray and Datascope Passport, Spectrum, Trio, BeneView, BeneVision, BeneHeart, DPM, iMEC, cPM, ePM, PM-series, Expert, and MPM monitors, plus Edan X12 and iM-series and Midmark Cardell Touch (see the Specifications tab for the full list). Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | EL-MR5-90G-A |
| Replaces OEM Part | Mindray / Datascope 0012-00-1262-01 |
| Category | ECG Leadwire Set |
| Lead Count | 5-Lead (Limb and Chest Leads) |
| Color Code Standard | AHA (RA White, LA Black, RL Green, LL Red, V Brown) |
| Electrode Termination | Grabber / Pinch |
| Trunk Cable Connector | Molded, Twin Pin |
| Lead Length | 3 ft (0.9 m) |
| Shielding | Shielded |
| Jacket Material | TPU, Latex-Free |
| Patient Size | Adult / Pediatric |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
Used with a compatible Mindray / Datascope 3/5-lead ECG trunk cable that accepts twin-pin leadwires.
| Manufacturer | Compatible Models |
| Mindray / Datascope | BeneHeart D3, BeneHeart D6, BeneView T1, BeneView T5, BeneView T8, BeneVision N1, DPM 4, DPM 5, DPM 6, DPM 7, Expert, MEC-1000, MPM, PM-5000, PM-6000, PM-8000, PM-8000 Express, PM-9000Vet, Passport 2, Passport 2LT, Passport 8, Passport 12, Passport 12m, Passport 17m, Passport XG, Spectrum, Spectrum OR, Trio, cPM 8, cPM 12, ePM 10M, ePM 12M, iMEC 5, iMEC 6, iMEC 7, iMEC 8, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iPM-9800, iPM 12Vet |
| Edan | X12, iM20, iM70, iM80 |
| Midmark / Cardell | Touch, Touch (Vet) |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Mindray / Datascope | 0012-00-1262-01 (18 in) |
| Mindray / Datascope | 0012-00-1262-02 (24 in), 0012-00-1262-03 (40 in), 0012-00-1054-04 (40 in) |
| Mindray / Datascope | 0010-30-42727, 0010-30-42729, 0010-30-43144, 0010-30-43146 |
| Mindray | EL6501A, EL6503A (Long) |
| Draeger | 2606498 |
| AMC | LW-3700024/5DS (24 in) |
| Fukuda Denshi | CMF-700-5FA |
| Sage | L04-05-29P |
IPR Medical buys, sells, repairs, and stocks parts for the Mindray 0012-00-1262-01 5-Lead ECG Leadwire Set. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Datascope, Mindray, or any other manufacturer or supplier named on this page. Datascope, Mindray, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Mindray 0012-00-1262-01 Compatible 5-Lead ECG Leadwire Set?
The Mindray 0012-00-1262-01 compatible 5-lead ECG leadwire set (SKU EL-MR5-90G-A) is a reusable, aftermarket replacement (not OEM) for the Mindray / Datascope 5-lead grabber leadwire set. It carries the five AHA-coded limb and chest leads (RA white, LA black, RL green, LL red, V brown) from the electrodes to a compatible Mindray / Datascope 3/5-lead ECG trunk cable. Each lead ends in a pinch-style grabber that clips onto the electrode, and the shielded leads are 3 ft (0.9 m) long.
Compatible Monitor Models
Through a compatible Mindray / Datascope 3/5-lead trunk cable, this set is used with the Mindray and Datascope Passport 2, Passport 2LT, Passport XG, Passport 8, Passport 12, Passport 12m, Passport 17m, Spectrum, Spectrum OR, Trio, Expert, MPM, DPM 4 through DPM 7, the PM-5000, PM-6000, PM-8000, PM-8000 Express and PM-9000Vet, the iPM-9800 and iPM 12Vet, the iMEC 5 through iMEC 15S, MEC-1000, cPM 8, cPM 12, ePM 10M and ePM 12M, BeneView T1, T5 and T8, BeneVision N1, and BeneHeart D3 and D6. The same lead set also fits the Edan X12, iM20, iM70 and iM80 and the Midmark Cardell Touch and Touch (Vet). The full list is in the Specifications tab.
Design and Construction
The leads are shielded to help reduce electrical noise on the ECG signal, and they terminate in a molded twin-pin connector that plugs into the trunk cable. The lead jackets are TPU and latex-free. Facilities that prefer snap ends can use the companion Mindray 0012-00-1261-01 compatible snap leadwire set. The set is sized for adult and pediatric patients and ships one per bag.
When to Replace Your Mindray 5-Lead ECG Leadwire Set
Replace the set when ECG traces show noise, baseline wander, or intermittent lead-off alarms that clear when a lead is flexed, since these usually point to a broken conductor or failed shielding inside a lead. Grabber springs that no longer close firmly, cracked grabber housings, split jackets near the connector, faded color bands, or bent twin-pin contacts are also reasons to retire the set. Swapping in a known-good leadwire set is a quick way for biomedical staff to separate a leadwire fault from a trunk cable or monitor ECG input fault.
Cross Reference and Interchange Part Numbers
This set interchanges with Mindray / Datascope 0012-00-1262-01, the OEM 18 in grabber set, and serves as a replacement for the other-length 0012-00-1262-02 (24 in), 0012-00-1262-03 (40 in) and 0012-00-1054-04 (40 in) sets. It also cross-references Mindray 0010-30-42727, 0010-30-42729, 0010-30-43144, 0010-30-43146, EL6501A and EL6503A, Draeger 2606498, AMC LW-3700024/5DS (24 in), Fukuda Denshi CMF-700-5FA, and Sage L04-05-29P. Note that this set has 3 ft (0.9 m) leads, so length differs from some of the OEM numbers it replaces.
Why Source Mindray-Compatible ECG Leadwires from IPR Medical?
IPR Medical buys, sells, repairs, and stocks parts for Mindray and Datascope patient monitors, so our team can help match leadwires and trunk cables to the monitors in your fleet. Our in-house technicians repair and refurbish monitoring equipment, and we keep compatible ECG leadwires, trunk cables, and other monitoring accessories in stock to keep units in service. Browse more ECG cables and leadwires or contact us for help confirming the right part.
IPR Medical buys, sells, repairs, and stocks parts for the Mindray 0012-00-1262-01 5-Lead ECG Leadwire Set. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Datascope, Mindray, or any other manufacturer or supplier named on this page. Datascope, Mindray, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.


















