IPR Medical

Mindray 0012-00-1503-06 Compatible 3-Lead Mobility ECG Leadwire Set, AHA, Snap, Shielded, 3 ft (0.9 m)

$40.00

The Mindray 0012-00-1503-06 compatible 3-lead mobility ECG leadwire set (SKU EL-DT3-90S-A) is a reusable, aftermarket replacement (not OEM). It has shielded limb leads, snap ends, and AHA color coding, and it connects to a Mindray mobility 3/5-lead ECG trunk cable.

Lead Count 3-Lead (Limb Leads)
Standard AHA (RA White, LA Black, LL Red)
Electrode Ends Snap
Trunk Connector Mindray Mobility Style
Lead Length 3 ft (0.9 m), Shielded
Lifecycle Reusable, Latex-Free
Replaces Mindray / Datascope 0012-00-1503-06, 0012-00-1503-04, 0012-00-1503-05, and more

Works with: Mindray and Datascope Passport 2, 8, 12, 12m, 17m and V, plus V12, V21, Spectrum, DPM 6 and 7, Panorama, T1, ePM 10M and 12M, and BeneVision N-series monitors (see the Specifications tab for the full list). Browse more ECG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for Mindray patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: EL-DT3-90S-A Categories: , Tags: ,
Send In Mindray 0012-00-1503-06 Compatible 3-Lead Mobility ECG Leadwire Set, AHA, Snap, Shielded, 3 ft (0.9 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) EL-DT3-90S-A
Replaces OEM Part Mindray 0012-00-1503-06
Category ECG Leadwire Set (Mobility)
Lead Count 3-Lead (Limb Leads)
Color Code Standard AHA (RA White, LA Black, LL Red)
Electrode Termination Snap
Trunk Cable Connector Molded, Mindray Mobility Style
Pairs With OEM Trunk Cables Mindray 040-001416-00, 009-003652-00, 0012-00-1745-01, 0012-00-1745-03, 0012-00-1502-03
Lead Length 3 ft (0.9 m)
Shielding Shielded
Jacket Material TPU, Latex-Free
Patient Size Adult / Pediatric
Lifecycle Reusable
Packaging 1 per Bag

Compatible Monitor Models

Used with a compatible Mindray mobility 3/5-lead ECG trunk cable (not a standard, non-mobility trunk cable).

Manufacturer Compatible Models
Mindray / Datascope BeneVision N1, BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision N22, DPM 6, DPM 7, ePM 10M, ePM 12M, Panorama, Panorama Telepack 608, Passport 2, Passport 8, Passport 12, Passport 12m, Passport 17m, Passport V, Spectrum, Spectrum OR, T1, V-Series, V12, V21

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Mindray 0012-00-1503-06 (36 in / 91 cm)
Datascope 0012-00-1503-04 (18 in / 46 cm), 0012-00-1503-05 (24 in / 61 cm)
AMC LW-2910S29/3A
Unimed DT3-90S

IPR Medical buys, sells, repairs, and stocks parts for the Mindray 0012-00-1503-06 3-Lead Mobility ECG Leadwire Set. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Mindray, or any other manufacturer or supplier named on this page. Mindray, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Mindray 0012-00-1503-06 Compatible 3-Lead Mobility ECG Leadwire Set?

The Mindray 0012-00-1503-06 compatible 3-lead mobility ECG leadwire set (SKU EL-DT3-90S-A) is a reusable, aftermarket replacement (not OEM) for the Mindray / Datascope 3-lead mobility snap leadwire set. It carries three AHA-coded limb leads (RA white, LA black, LL red) from snap electrodes to a compatible Mindray mobility 3/5-lead ECG trunk cable. The shielded leads are 3 ft (0.9 m) long, matching the 36 in (91 cm) length of the OEM 0012-00-1503-06.


Compatible Monitor Models

Through a compatible Mindray mobility trunk cable, this set is used with the Mindray and Datascope Passport 2, Passport 8, Passport 12, Passport 12m, Passport 17m, Passport V, V12, V21 and V-Series, Spectrum and Spectrum OR, DPM 6 and DPM 7, Panorama and Panorama Telepack 608, T1, ePM 10M and ePM 12M, and BeneVision N1, N12, N15, N17, N19 and N22. The full list is in the Specifications tab.


Design and Construction

This is a mobility-style lead set: the three shielded leads terminate in a molded connector made for Mindray mobility trunk cables. Mindray pairs the 0012-00-1503-06 with its mobility trunk cables, including the 040-001416-00 12-pin mobility cable and 009-003652-00 12-pin ESIS mobility cable for the DPM 6, DPM 7, Passport 8, Passport 12, Passport 12m, Passport 17m and T1, the 0012-00-1745-01 and 0012-00-1745-03 (ESIS) cables for the Passport V, V12 and V21, and the 0012-00-1502-03 mobility ESIS cable for the Passport 2, Spectrum and Spectrum OR. These mobility cables are separate from the standard (non-mobility) trunk cables used with the 0012-00-1261 and 0012-00-1262 leadwire series, so confirm the trunk cable type before ordering. Each lead ends in a snap for standard snap electrodes, the jackets are TPU and latex-free, and the set is sized for adult and pediatric patients and ships one per bag.


When to Replace Your Mindray Mobility ECG Leadwire Set

Replace the set when ECG traces show noise, baseline wander, or intermittent lead-off alarms that clear when a lead is flexed, since these usually point to a broken conductor or failed shielding inside a lead. Loose or corroded snaps, split jackets near the connector, faded color bands, or damaged connector contacts are also reasons to retire the set. Swapping in a known-good leadwire set is a quick way for biomedical staff to separate a leadwire fault from a trunk cable or monitor ECG input fault.


Cross Reference and Interchange Part Numbers

This set interchanges with Mindray 0012-00-1503-06, the OEM 36 in (91 cm) 3-lead mobility snap set. It also replaces the Datascope 0012-00-1503-04 (18 in, 46 cm) and 0012-00-1503-05 (24 in, 61 cm) sets, which have shorter leads, and it cross-references AMC LW-2910S29/3A and Unimed DT3-90S.


Why Source Mindray-Compatible ECG Leadwires from IPR Medical?

IPR Medical buys, sells, repairs, and stocks parts for Mindray and Datascope patient monitors, so our team can help match leadwires and trunk cables to the monitors in your fleet. Our in-house technicians repair and refurbish monitoring equipment, and we keep compatible ECG leadwires, trunk cables, and other monitoring accessories in stock to keep units in service. Browse more ECG cables and leadwires or contact us for help confirming the right part.

IPR Medical buys, sells, repairs, and stocks parts for the Mindray 0012-00-1503-06 3-Lead Mobility ECG Leadwire Set. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Mindray, or any other manufacturer or supplier named on this page. Mindray, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.