Spacelabs 700-0030-00 Compatible SpO2 Adapter Cable, for Use with Nellcor OxiSmart Sensors, 7.9 ft (2.4 m)
The Spacelabs 700-0030-00 compatible SpO2 adapter cable (SKU SA-026-24) is a reusable aftermarket replacement (not OEM) with a 7.9 ft (2.4 m) cable, for use with Nellcor OxiSmart sensors.
| Cable Type | SpO2 Adapter Cable |
| SpO2 Technology | Nellcor OxiSmart |
| Cable Length | 7.9 ft (2.4 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
| Replaces | Spacelabs 700-0030-00 |
Works with: select Spacelabs models such as the 91369, mCare 300, and Ultraview SL 2700. See the Specifications tab for the full list. Browse more SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for Spacelabs monitoring equipment and SpO2 accessories. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SA-026-24 |
| Replaces OEM Part | Spacelabs 700-0030-00 |
| Category | Cables & Sensors > SpO2 |
| Cable Type | SpO2 Adapter Cable |
| SpO2 Technology | Nellcor OxiSmart |
| Used With | Nellcor OxiSmart sensors |
| Cable Length | 7.9 ft (2.4 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Spacelabs | 1050, 1600, 1700, 90367, 90369, 90469, 90496, 91220, 91367, 91369, 91496, 91496-U, 91496M, mCare 300, Ultraview SL 2700 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Spacelabs | 700-0030-00, 700-0730-00 |
| AMC | CB-A400-1103A |
| Beta Biomed | B505-1020E |
| Curbell | 5587 |
| Sage | E03-30M |
| Tenacore | TE1923 |
| Unimed | U708-74 |
IPR Medical buys, sells, repairs, and stocks parts for Spacelabs patient monitors and SpO2 adapter cables. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Spacelabs, Nellcor, or any other manufacturer or supplier named on this page. Spacelabs, Nellcor, OxiSmart, Ultraview, mCare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Spacelabs 700-0030-00 Compatible SpO2 Adapter Cable?
The IPR Medical SA-026-24 is a compatible aftermarket (not OEM) SpO2 adapter cable that replaces the Spacelabs 700-0030-00. Designed for use with Nellcor OxiSmart sensors, this reusable accessory has a 7.9 ft (2.4 m) cable and goes back into service after cleaning.
Compatible Monitor Models
The adapter is listed for select Spacelabs models identified by number, such as the 1050, 1600, 1700, 90367, 90369, 90469, and 90496, as well as the 91220, 91367, 91369, and several 91496 variants. The mCare 300 and the Ultraview SL 2700 are on the list too. Because some entries differ only by a suffix, check the full designation on your equipment against the Compatible Monitor Models table on the Specifications tab.
Design and Construction
Units are bagged individually, each with a 7.9 ft (2.4 m) cable designed for use with Nellcor OxiSmart SpO2 technology. Reuse it from patient to patient after cleaning according to your facility’s protocol, and examine the cable and both ends whenever it is reconnected.
When to Replace Your SpO2 Adapter Cable
Retire the SA-026-24 when its jacket is gouged or cracked, when a connector housing is broken, or when the contacts at either end look bent or corroded. Intermittent saturation values, recurring sensor-disconnect alerts, and a signal that returns only when the cable is held at a certain angle all suggest an internal break. Testing with a spare adapter that is known to be good will isolate the fault.
Cross Reference and Interchange Part Numbers
Spacelabs 700-0030-00 is the OEM part this adapter replaces, and a second Spacelabs number, 700-0730-00, is also linked to it. Six aftermarket brands list their own equivalents, and the Specifications tab sorts those numbers brand by brand.
Why Source SpO2 Adapter Cables from IPR Medical?
The SA-026-24 is sold by IPR Medical, where the work is buying, selling, repairing, and stocking parts for patient monitoring equipment and infusion pumps. Repair requests are handled by IPR Medical’s in-house technicians, and the company carries ISO 9001:2015 certification as an independent service organization. Call 855-477-8866 for help with an order, or browse our SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for Spacelabs patient monitors and SpO2 adapter cables. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Spacelabs, Nellcor, or any other manufacturer or supplier named on this page. Spacelabs, Nellcor, OxiSmart, Ultraview, mCare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.