Spacelabs 700-0792-00 Compatible SpO2 Adapter Cable, for Use with Nellcor OxiMax Sensors, 9.8 ft (3.0 m)
The Spacelabs 700-0792-00 compatible SpO2 adapter cable (SKU SA-026X-30) is a reusable aftermarket replacement (not OEM) with a 9.8 ft (3.0 m) cable, for use with Nellcor OxiMax sensors.
| Cable Type | SpO2 Adapter Cable |
| SpO2 Technology | Nellcor OxiMax |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
| Replaces | Spacelabs 700-0792-00 |
Works with: select Spacelabs models such as the 90369, 91496, and Ultraview SL. See the Specifications tab for the full list. Browse more SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for Spacelabs patient monitors and pulse oximetry accessories. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SA-026X-30 |
| Replaces OEM Part | Spacelabs 700-0792-00 |
| Category | Cables & Sensors > SpO2 |
| Cable Type | SpO2 Adapter Cable |
| SpO2 Technology | Nellcor OxiMax |
| Used With | Nellcor OxiMax sensors |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Spacelabs | 96, 904, 1050, 1600, 1700, 90369, 90469, 91220-B, 91390, 91496, Ultraview, Ultraview SL |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Spacelabs | 700-0792-00 |
| Curbell | 5589, CB-A400-2003 |
| Unimed | U710X-74 |
IPR Medical buys, sells, repairs, and stocks parts for SpO2 adapter cables and Spacelabs monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Spacelabs, Nellcor, or any other manufacturer or supplier named on this page. Spacelabs, Nellcor, OxiMax, Ultraview, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Spacelabs 700-0792-00 Compatible SpO2 Adapter Cable?
The IPR Medical SA-026X-30 is a compatible aftermarket (not OEM) SpO2 adapter cable that replaces the Spacelabs 700-0792-00. It has a 9.8 ft (3.0 m) cable, is intended for use with Nellcor OxiMax sensors, and can be cleaned and used again.
Compatible Monitor Models
Select Spacelabs models listed for this adapter include the 1050, 1600, and 1700, the 90369 and 90469, the 91220-B, 91390, and 91496, plus Ultraview and Ultraview SL entries. A few shorter model entries are also on record, so read through the Compatible Monitor Models table on the Specifications tab to confirm your model before ordering.
Design and Construction
The SA-026X-30 is for use with Nellcor OxiMax SpO2 technology, and its cable length is 9.8 ft (3.0 m). It ships as a single adapter in each bag. As a reusable part, it should be cleaned per facility protocol between patients and checked for wear before it is put back into service.
When to Replace Your SpO2 Adapter Cable
Replace this adapter if the jacket is abraded through, if a connector is cracked or wobbles once it is plugged in, or if the cable holds a sharp kink that will not relax. Watch for SpO2 numbers that freeze or disappear, frequent check-sensor messages, and readings that recover only after the cable is straightened. Connecting a known-good adapter in its place is the simplest way to confirm the cause.
Cross Reference and Interchange Part Numbers
The only Spacelabs number tied to this adapter is 700-0792-00, the OEM part it replaces. Two aftermarket brands, one of them with a pair of numbers, complete the cross-reference table on the Specifications tab.
Why Source SpO2 Adapter Cables from IPR Medical?
IPR Medical deals in parts for patient monitoring systems and infusion pumps: it buys, sells, repairs, and stocks them. IPR Medical, an ISO 9001:2015-certified independent service organization, completes its repairs in-house. To order or ask a question, call 855-477-8866, or find related accessories in our SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for SpO2 adapter cables and Spacelabs monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Spacelabs, Nellcor, or any other manufacturer or supplier named on this page. Spacelabs, Nellcor, OxiMax, Ultraview, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.