Spacelabs 700-0006-00 Compatible 3-Lead ECG Leadwire Set, Grabber/Pinch, AHA, Individual, 3.0 ft (0.9 m)

$40.00

The Spacelabs 700-0006-00 compatible 3-lead ECG leadwire set (SKU EL-SLS3-90G-A) is a reusable aftermarket replacement (not OEM) with grabber/pinch electrode ends, individual leads, a Spacelabs TruLink lead type, AHA color coding, and a 3.0 ft (0.9 m) length.

Lead Count 3-Lead
Electrode End Grabber/Pinch
Distal Connector Individual
Lead Type Spacelabs TruLink
Cable Length 3.0 ft / 35.4 in (0.9 m)
Replaces Spacelabs 700-0006-00

Works with: select Spacelabs models such as the 90309 and 91387, plus Elance Series and Ultraview SL entries. See the Specifications tab for the full list. Browse more ECG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for Spacelabs patient monitors and ECG accessories. Call 855-477-8866 or email cs@iprmed.com.

SKU: EL-SLS3-90G-A Categories: , Tags: ,
Send In Spacelabs 700-0006-00 Compatible 3-Lead ECG Leadwire Set, Grabber/Pinch, AHA, Individual, 3.0 ft (0.9 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) EL-SLS3-90G-A
Replaces OEM Part Spacelabs 700-0006-00
Category Cables & Sensors > ECG/EKG
Product ECG Leadwire Set
Lead Count 3-Lead
Lead Placement Limb Lead
Electrode End Grabber/Pinch
AHA/IEC Code AHA (RA white, LA black, LL red)
Distal Connector Individual
Feature Shielded
Lead Type Spacelabs TruLink
Cable Length 3.0 ft / 35.4 in (0.9 m)
Intended Use Monitoring
Lifecycle Reusable
Packaging 1 set per bag

Compatible Monitor Models

Manufacturer Compatible Models
Spacelabs 90309, 90367, 90367 Ultraview, 90369, 90369 Ultraview, 90492, 90496, 90496 Ultraview, 91220, 91220 mCare 300, 91369, 91387, 91496, 93300, Elance Series, Ultraview SL

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Spacelabs 700-0006-00, 700-0006-02
AMC LW-3500024/3A, LW-3500040/3A
Sage L03-03-29P
Unimed SLB3-90P

IPR Medical buys, sells, repairs, and stocks parts for Spacelabs patient monitors and the ECG leadwires that connect to them. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Spacelabs, or any other manufacturer or supplier named on this page. Spacelabs, TruLink, Ultraview, Elance, mCare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Spacelabs 700-0006-00 Compatible 3-Lead ECG Leadwire Set?

The IPR Medical EL-SLS3-90G-A is a compatible aftermarket (not OEM) 3-lead ECG leadwire set that replaces the Spacelabs 700-0006-00. Its three individual leads end in grabber/pinch connections and are intended for limb lead ECG monitoring. The set carries a Spacelabs TruLink lead type designation, is reusable, and measures 3.0 ft (0.9 m).


Compatible Monitor Models

The EL-SLS3-90G-A is listed for select Spacelabs models, for example the 90309, 90492, and 91387, together with Elance Series and Ultraview SL entries. A few model numbers are listed both on their own and with a family name attached, such as 90369 and 90369 Ultraview, and the table keeps each entry exactly as listed. If the designation on your monitor does not appear in the compatibility table on the Specifications tab, our team can check the fit with you by phone before you order.


Design and Construction

Each of the three limb leads finishes in a grabber/pinch end, and the leads follow AHA color coding: RA white, LA black, LL red. The distal connector type is Individual, the lead type is Spacelabs TruLink, and the leads are shielded. Overall length is 3.0 ft (0.9 m), or about 35.4 in. Packed one set per bag, it is a reusable accessory, so clean and inspect it between patients as your facility protocol requires.


When to Replace Your 3-Lead ECG Leadwire Set

Grabber jaws that slip off the electrode tab or no longer spring closed are a common reason to retire a set like this one. Look also for insulation that has split, hardened, or discolored after repeated cleaning, and for a connector end that is cracked or loose. On the monitor, frequent lead-off messages and a baseline that turns ragged whenever the patient shifts often point to a broken conductor inside one of the leads. Swapping in a known-good set for a few minutes is a fast way to confirm the diagnosis.


Cross Reference and Interchange Part Numbers

Spacelabs 700-0006-00 is the primary OEM reference for this set, and Spacelabs 700-0006-02 is listed as a second OEM cross-reference. On the aftermarket side, the cross-reference table on the Specifications tab lists four more numbers spread across three brands.


Why Source ECG Leadwires from IPR Medical?

Compatible leadwires for Spacelabs monitors are one small part of the work at IPR Medical, an ISO 9001:2015-certified independent service organization whose business centers on buying, selling, repairing, and stocking parts for patient monitors and infusion pumps. When a Spacelabs monitor needs service, our own technicians carry out the repair in-house. To order or ask about lead type, phone 855-477-8866; the rest of our ECG cables and leadwires are one click away.

IPR Medical buys, sells, repairs, and stocks parts for Spacelabs patient monitors and the ECG leadwires that connect to them. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Spacelabs, or any other manufacturer or supplier named on this page. Spacelabs, TruLink, Ultraview, Elance, mCare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.