Nellcor DEC-8 Compatible SpO2 Adapter Cable for OxiMax Sensors, DB9 Male to Female, 7.9 ft
The Nellcor DEC-8 compatible SpO2 adapter cable (SKU SA-001X-24) is a reusable, aftermarket replacement (not OEM). This DB9-to-DB9 extension cable connects Nellcor OxiMax-compatible SpO2 sensors to the compatible pulse oximeters and patient monitors listed in the Specifications tab.
| Cable Type | SpO2 Adapter (Extension) Cable, Reusable |
| SpO2 Technology | Nellcor OxiMax Compatible |
| Monitor Connector | Male 9-Pin D-Sub (DB9), Dual Keyed |
| Sensor Connector | Female 9-Pin D-Sub (DB9) |
| Cable Length | 7.9 ft (2.4 m) |
| Replaces | Nellcor DEC-8 |
Works with: Nellcor N-series and NPB-series pulse oximeters, plus select GE Healthcare, Marquette, Mindray, Datascope, Welch Allyn, Nihon Kohden, Criticare, and Physio-Control monitors. See the Specifications tab for the full list, including models that require the Nellcor SpO2 option. Browse more SpO2 sensors and adapter cables.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SA-001X-24 |
| Replaces OEM Part | Nellcor DEC-8 |
| Category | SpO2 Adapter (Extension) Cable |
| SpO2 Technology | Nellcor OxiMax Compatible |
| Monitor Connector | Male 9-Pin D-Sub (DB9), Dual Keyed |
| Sensor Connector | Female 9-Pin D-Sub (DB9) |
| Cable Length | 7.9 ft (2.4 m) |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Nellcor | N-10, N-20, N-30, N-45, N-65, N-85, N-100, N-180, N-190, N-200, N-390, N-395, N-560, N-595, N-600, N-600x, N-3000 (Symphony), N-6000, NPB-40, NPB-70, NPB-75, NPB-190, NPB-195, NPB-290, NPB-295, NPB-3900, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-4000, NPB-4000C, PM10N, PM100N |
| Mindray | BeneHeart D3, BeneView T1, BeneVision N1, BeneVision N12, BeneVision N12 Neo, BeneVision N15, BeneVision N17, BeneVision N22, BeneVision ePM 10M, BeneVision ePM 12, BeneVision ePM 12M, BeneVision ePM 15, BeneVision VS-900, Duo, MEC-1200Vet, PM-9000Vet, Passport 2, Passport 8, Passport 12, Passport V, Spectrum, Spectrum OR, Trio |
| Datascope | DPM5, DPM6, DPM7, V-Series, V12 |
| Datascope (with Nellcor SpO2 Option) | Accutorr Plus, Expert, Passport, Passport 5L, Passport EL, Passport XG |
| GE Healthcare | 129, 188, 511, 9710, 9720 Plus, Carescape B650, Carescape V100, Compact, Compact DINAMAP MPS, Compact S, Compact TS, E-NSAT, M-NSAT Modules, MPS, Pro 200, Pro 300, Pro 400, Pro 1000, Pro 1000 V3, Pro Series, Pro Series V2, ProCare, ProCare 200, ProCare 400, ProCare Auscultatory 400, Select |
| Marquette | Dash 2500, Dash 3000, Dash 4000, Dash 5000, i/9500, PDM Module, Procare B40, Solar 8000, Solar 8000M, Tram 451 |
| Welch Allyn | 1500, 42NT0-E1 LXi, 520 Series, 52N Series, 52S Series, 53N0P, 53NT0, 53NTP, 6000 Series, 71WE-B, 71WT-B Connex Spot, 71WX-B Connex Spot, 73WE-B, 73WT-B Connex Spot, 73WX-B, Atlas (Nellcor SpO2), Atlas 6200 Series, Encore 202EL, Micropaq (Nellcor SpO2), Micropaq 406/408, Propaq 106-EL, Propaq 202-EL, Propaq 204-EL, Propaq 206-EL, Propaq 244, Propaq CS, Propaq LT, Series 420, Spot Vital Signs 42NOB, Spot Vital Signs 42NTB-E1 |
| Philips | Heartstream XL, IntelliVue FAST-SpO2, IntelliVue MP2, IntelliVue MP70, IntelliVue MX450, M1020B, M2601A, M3000A, M3001A, M3001A A02, M3001A A02C06, M3001A A02C12, M3001A A02C18, M3001A A04, M3001A A04C06, M3001A A04C12, M3001A A04C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, Prodigy, SureSigns VS1, SureSigns VS2, SureSigns VS3, SureSigns VS4 |
| Physio-Control | Lifepak 12, Lifepak 15 |
| Nihon Kohden | BSM-2300, BSM-2304A, BSM-4100, BSM-4104A, BSM-4114A, BSM-5100 |
| Criticare / CSI | 506DNV3, 506DNVP3, 506LN3, 506LNP3, 506LNT3, 506LNTP3, 506LNV3, 506LNVP3, 506NV3, 506NVP3 |
| BCI | 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, 9100, Advisor, Advisor S#155, Autocorr, Mini Torr, Mini Torr Plus |
| Cardell | 9403, 9404, 9405, 9500 Series, 9500HD, MAX-12 Duo HD |
| Colin | BP-306, BP-508, BP-808, BP-88, BP-88S, BP-S510, Press-Mate, T105NXM |
| Datex-Ohmeda | Cardiocap/5, enGuard CM5, Vitalmax 800 Series (Nellcor SpO2) |
| DRE | ASM 5000, Waveline, Waveline EZ MAX, Waveline Plus |
| Edan | elite V8, iM3, iM50 |
| Fukuda Denshi | Dynascope DS-7100, LX-7230N |
| Healthdyne | 930, 9705, 970S, 970SE |
| Invivo | Escort II OPT30, MDE Escort Prism, Prism |
| Ivy Biomedical | 405P, 405T, 450C, 700, CM5 |
| Nonin | 7500, 8500, 8604, 9600, 9700 |
| CAS Med | OscilloMate 9002, OscilloMate 9302S, OscilloMate 9303 |
| Biolight | M8500, M9500, Q3 |
| Baxter | Explorer, Monarch |
| Goldway | Vet 420A, Vet 600A |
| Other | Artema S&W Diascope, Bionics BPM-200, Bird Sentry, Charmcare CX100, Digicare LW600, Draeger Narkomed 6400, Guthan 1000, Oridion Capnostream 20, Siemens Axiom Sensis XP, Suntech 247B, Waltvick Humyzin |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Nellcor | DEC-8, 45268 |
| AMC | CB-A400-1011D8 |
| Beta Biomed | B400-1011E |
| Envitec | X-4212 |
| Marquette / GE Healthcare | EC8 |
| Pacific Medical | NXNE2626-8, NXNE400 |
| Philips | M4787A |
| Physio-Control | 11110-000176 |
| Sage | E06-22M |
| Spacelabs | 700-0287-00, 700-0290-0 |
| Tenacore | TE1713 |
| Unimed | U708-71, U710-71 |
| Welch Allyn | 008-0742-00, 008-1012-00 |
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment, including compatible SpO2 adapter cables for Nellcor OxiMax sensors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiMax, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Nellcor DEC-8 Compatible SpO2 Adapter Cable?
The Nellcor DEC-8 compatible SpO2 adapter cable (SKU SA-001X-24) is a reusable, aftermarket replacement (not OEM). It is a 7.9 ft (2.4 m) extension cable that connects a Nellcor OxiMax-compatible SpO2 sensor to the SpO2 input of a compatible pulse oximeter or patient monitor. The monitor end is a dual-keyed male 9-pin D-sub (DB9) connector, and the sensor end is a female 9-pin D-sub (DB9) connector that accepts the sensor plug.
Compatible Monitor Models
This adapter cable is compatible with a wide range of Nellcor pulse oximeters, including the N-series (such as the N-560, N-595, and N-600x) and NPB-series (such as the NPB-40, NPB-190, NPB-295, and NPB-4000). It is also compatible with select GE Healthcare, Marquette, Mindray, Datascope, Welch Allyn, Nihon Kohden, Criticare, BCI, and Physio-Control monitors and defibrillators, along with monitors from many other manufacturers. Some Datascope models are compatible only when equipped with the Nellcor SpO2 option. The complete model list is in the Specifications tab.
Design and Construction
The adapter cable is designed for Nellcor OxiMax sensor technology, so it should be paired with OxiMax-compatible sensors. The dual-keyed male DB9 connector plugs into the monitor or oximeter SpO2 input, and the female DB9 connector accepts the standard 9-pin sensor plug. At 7.9 ft (2.4 m), the cable gives staff room to position the monitor away from the bedside while the sensor stays on the patient. It is reusable and ships one per bag.
When to Replace Your SpO2 Adapter Cable
Replace the adapter cable when the monitor shows sensor-off or no-sensor messages with a known-good sensor attached, or when SpO2 and pulse readings drop out or turn erratic as the cable is moved. Cracked or kinked jackets, bent pins or damaged sockets at either DB9 connector, and loose or worn connector shells are also signs the cable should be retired. Testing with a known-good adapter cable is a quick way for biomedical staff to separate a cable fault from a sensor or monitor SpO2 board fault.
Cross Reference and Interchange Part Numbers
This cable interchanges with Nellcor DEC-8 and 45268, AMC CB-A400-1011D8, Beta Biomed B400-1011E, Envitec X-4212, Marquette / GE Healthcare EC8, Pacific Medical NXNE2626-8 and NXNE400, Physio-Control 11110-000176, Sage E06-22M, Spacelabs 700-0287-00 and 700-0290-0, Tenacore TE1713, Unimed U708-71 and U710-71, and Welch Allyn 008-0742-00 and 008-1012-00, plus the additional numbers in the Specifications tab. Contact IPR Medical with your monitor model or existing cable part number and we will confirm the match.
Why Source Nellcor-Compatible SpO2 Cables from IPR Medical?
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment, so our team can help match SpO2 sensors and adapter cables to the monitors in your fleet. Our in-house technicians repair and refurbish monitoring equipment, and we keep compatible SpO2 cables and other monitoring accessories in stock to keep units in service. Browse more SpO2 sensors and adapter cables or contact us for help confirming the right part.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment, including compatible SpO2 adapter cables for Nellcor OxiMax sensors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiMax, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.



















