Masimo 2318 (LNCS Pdtx-3) Compatible Pediatric Adhesive SpO2 Sensor, Disposable, 3.0 ft (0.9 m), Box of 20
The Masimo 2318 (LNCS Pdtx-3) compatible SpO2 sensor (SKU SSD-005RB-W09P) is a disposable, aftermarket replacement (not OEM) pediatric adhesive sensor for Masimo SET-equipped monitors, built to match the original’s fit, form, and function.
| Sensor Type | Non-Woven Adhesive (Finger) |
| Patient Size | Pediatric, 22–110 lbs (10–50 kg) |
| Connector | Masimo LNCS, Male 9-Pin |
| SpO2 Technology | Masimo SET (LNCS) |
| Cable Length | 3.0 ft (0.9 m) |
| Lifecycle | Disposable, Latex-Free |
| Packaging | 20 per Box |
| Replaces | Masimo 2318, 1860, Physio-Control 11171-000020, and more |
Works with: Masimo Radical-7, Rad-5, Rad-8, and Rad-57; Masimo SET-equipped Mindray/Datascope Passport and Spectrum, GE Dash, Solar, and CARESCAPE, Philips IntelliVue, Physio-Control Lifepak 11 through 20e, Zoll E, M, R, and X Series, Draeger Infinity, and Welch Allyn Propaq and Spot Vital Signs monitors. Some monitors require an LNCS patient cable. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for Masimo patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SSD-005RB-W09P |
| Replaces OEM Part | Masimo 2318 (LNCS Pdtx-3) |
| Category | Disposable SpO2 Sensor |
| Sensor Type | Non-Woven Adhesive (Finger) |
| Patient Size | Pediatric |
| Patient Weight Range | 22–110 lbs (10–50 kg) |
| Cable Length | 3.0 ft (0.9 m) |
| Connector | Masimo LNCS, Male 9-Pin D-Sub, Triple Keyed |
| SpO2 Technology | Masimo SET (LNCS) |
| Lifecycle | Disposable, Single-Patient Use |
| Latex-Free | Yes |
| Sterility | Non-Sterile |
| Packaging | 20 per Box |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Masimo | Pronto-7, Rad-5, Rad-8, Rad-57, Rad-87, Radical-7 |
| Mindray / Datascope | Accutorr 3, Accutorr 7, Accutorr Plus, Accutorr V, BeneView T1, BeneView T5, BeneView T8, BeneVision N1, BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision N22, BeneVision TMS60, BeneVision TMS80, BeneHeart D6, cPM 8, cPM 12, DPM4, DPM6, DPM7, Duo, ePM 10M, ePM 12M, EPM4, iMEC 5, iMEC 6, iMEC 7, iMEC 8, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iPM-9800, MEC 12, MPM, Passport 2, Passport 2LT, Passport 8, Passport 12, Passport V, Passport XG, PM 6000, PM 6800, PM 7000, PM 8000, PM 9000, Spectrum, Spectrum OR, T8, Trio, V12, V21, VS 8, VS 8A, VS 8C, VS 9, VS 9A, VS 9C, VS 800 |
| GE Healthcare (Marquette) | Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Eagle, Eagle 1000, PDM Module, ProCare B40, Solar 7000, Solar 8000, Solar 8000M, i/9500 (Tram 451N5/851N5), Tram 451, TRAM Modular, x50SL Series, SMK SMV |
| GE Healthcare (Dinamap) | CARESCAPE B650, CARESCAPE B850, CARESCAPE V100, ProCare with Masimo (Pro 1000, Pro 300V2), ProCare 300, ProCare Auscultatory 400, ProSeries V2, V300 |
| GE Healthcare (Corometrics) | 128, 250, 250cx, TRAM 450SL |
| Datex-Ohmeda | Giraffe Infant Warmer, S/5 |
| Philips | Heartstream XL, IntelliVue FAST-SpO2, IntelliVue MP70, M1020B, M2601A, M3000A, M3001A, M3001A A03, M3001A A03C06, M3001A A03C12, M3001A A03C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A MP2, M8105A MP5, M8105AS, MP30, SureSigns VS2, SureSigns VS3, VM4 |
| Physio-Control (Stryker) | Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20e |
| Zoll | E Series, M Series, R Series, X Series |
| Draeger | Infinity Delta, Infinity Delta XL, Infinity Kappa, Infinity M540, Narkomed 6400 |
| Welch Allyn | 1500, 45NE0-E1 LX, 53S00, 53S0P, 53ST0, 53STP, 64H Series, 64M Series, 65H Series, 65M Series, 67M Series, 68M Series, Propaq CS, Propaq LT, Spot Vital Signs 42MOB, Spot Vital Signs 42MTB-E1, Spot Vital Signs LXi |
| Invivo | Escort II OPT30 Prism, T8 |
| Bitmos | sat 800, sat 801, sat 805, sat 816, satPuls |
| Comen | K12 Pro |
| Mennen | Horizon XVu |
| Respironics | Alice 5 |
| Penlon InterMed | Masimo SET-Equipped Models |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Masimo | 2318 (LNCS Pdtx-3), 2602 (LNCS Pdtx-3), 1860 (LNCS Pdtx, 18 in) |
| Datascope (Mindray) | 0600-00-0122, 520P-30-64201 |
| Draeger | MP00793 |
| GE Healthcare (Marquette) | 2027254-001 |
| Philips | 989803148241 |
| Physio-Control (Stryker) | 11171-000020 |
| Zoll | 8000-0321 |
IPR Medical buys, sells, repairs, and stocks parts for the Masimo 2318 LNCS Pdtx-3 SpO2 Sensor. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, Philips, or any other manufacturer or supplier named on this page. Masimo, Philips, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Compatible Masimo 2318 LNCS Pdtx-3 SpO2 Sensor?
The Masimo 2318 (LNCS Pdtx-3) compatible SpO2 sensor (IPR SKU SSD-005RB-W09P) is a single-patient-use adhesive finger sensor for pediatric patients on Masimo SET-equipped monitors. It is a compatible aftermarket replacement, not an OEM Masimo product, built to match the fit, form, and function of the original. The sensor has a non-woven adhesive wrap sized for smaller fingers and a 3.0 ft (0.9 m) cable that ends in a Masimo LNCS connector. It plugs directly into LNCS-equipped Masimo devices, or into an LNCS patient cable on other brands’ monitors that use Masimo SET technology. Adhesive sensors stay in place on active children, and single-patient use removes the need to reprocess reusable sensors between patients.
Compatible Monitor Models
Because LNCS is the most widely licensed Masimo sensor interface, this compatible sensor works across a very broad installed base. Compatibility includes Masimo Radical-7, Rad-5, Rad-8, Rad-57, Rad-87, and Pronto-7; Mindray and Datascope Passport, Spectrum, Accutorr, BeneView, BeneVision, ePM, iMEC, VS, and PM series monitors; GE Healthcare Dash, Solar, Eagle, Tram, and CARESCAPE B650, B850, and V100 monitors, plus Dinamap ProCare and Corometrics fetal monitors; Philips IntelliVue MP-series and M3001A MMS configurations, SureSigns VS2 and VS3, and Heartstream XL; Physio-Control Lifepak 11, 12, 15, 20, and 20e; Zoll E, M, R, and X Series; Draeger Infinity Delta, Kappa, M540, and Narkomed 6400; Welch Allyn Propaq, Spot Vital Signs, and 64, 65, 67, and 68 series; and Datex-Ohmeda S/5 and Giraffe Infant Warmer. The Specifications tab lists every compatible model. Confirm that your device is configured for Masimo SET oximetry, and whether it requires an LNCS patient cable, before ordering.
Design and Construction
The non-woven adhesive wrap conforms to a child’s fingertip and holds the emitter and detector in alignment through movement, which makes it well suited for continuous monitoring in the PICU, pediatric ED, OR, and during transport. The sensor is sized for pediatric patients weighing approximately 22 to 110 lbs (10 to 50 kg). The 3.0 ft (0.9 m) cable terminates in a triple-keyed male 9-pin LNCS connector. Each sensor is single-patient use, latex-free, and non-sterile, and sensors are packaged 20 per box.
When to Replace Your 2318 LNCS Pdtx-3 SpO2 Sensor
Adhesive sensors are designed for a single patient and should be discarded when that patient is discharged or the sensor is removed. Replace the sensor sooner if the adhesive no longer holds securely, the sensor becomes soiled or wet, the emitter or detector shifts off the nail bed, or the site needs to be rotated per your facility’s skin-integrity protocol, which is especially important for pediatric skin. Persistent “sensor off” or low-signal alarms on a well-perfused patient are also a cue to apply a fresh sensor at a new site. Keeping adequate box stock on each pediatric unit prevents staff from substituting adult sensors or reusing sensors past their intended life.
Cross Reference and Interchange Part Numbers
This compatible sensor cross-references to Masimo 2318 (LNCS Pdtx-3), 2602 (LNCS Pdtx-3), and 1860 (LNCS Pdtx), and to the OEM-labeled equivalents sold under other monitor brands, including Datascope 0600-00-0122 and 520P-30-64201, Draeger MP00793, GE Healthcare 2027254-001, Philips 989803148241, Physio-Control 11171-000020, and Zoll 8000-0321. The Masimo 1860 reference is the 18-inch-cable version of the same pediatric adhesive sensor. This listing is the 3.0 ft (0.9 m) version.
Why Source Masimo-Compatible SpO2 Sensors from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for infusion pumps and patient monitoring equipment. Compatible disposable SpO2 sensors are one of the highest-volume consumables on any unit, and sourcing them as compatible replacements gives materials managers meaningful savings over OEM pricing without changing workflows. Our team can confirm fit against your monitor model and patient cable before you order, and we also offer in-house repair services, replacement parts, and refurbished equipment, so you can source consumables and service from a single partner.
IPR Medical buys, sells, repairs, and stocks parts for the Masimo 2318 LNCS Pdtx-3 SpO2 Sensor. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, Philips, or any other manufacturer or supplier named on this page. Masimo, Philips, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.