Physio-Control 11111-000018 Compatible 4-Lead One-Piece ECG Cable, Snap, AHA, Defib-Proof, 8.2 ft + 3.0 ft (2.5 m + 0.9 m)
The Physio-Control 11111-000018 compatible 4-lead one-piece ECG cable (SKU EC-4039RS-A) is a reusable aftermarket replacement (not OEM) with snap electrode ends, limb lead placement, AHA color coding, a defib-proof feature, and an 8.2 ft + 3.0 ft (2.5 m + 0.9 m) length.
| Lead Count | 4-Lead |
| Lead Placement | Limb Lead |
| Electrode End | Snap |
| Feature | Defib-Proof (with Resist) |
| Cable Length | 8.2 ft + 3.0 ft (2.5 m + 0.9 m) |
| Replaces | Physio-Control 11111-000018 |
Works with: select Physio-Control Lifepak models. For the complete list, see the Specifications tab. Browse more ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for patient monitors and ECG cables. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | EC-4039RS-A |
| Replaces OEM Part | Physio-Control 11111-000018 |
| Category | Cables & Sensors > ECG/EKG |
| Product | One-Piece ECG Cable |
| Lead Count | 4-Lead |
| Lead Placement | Limb Lead |
| Electrode End | Snap |
| AHA/IEC Code | AHA (RA white, LA black, LL red, RL green) |
| Feature | Defib-Proof (with Resist) |
| Cable Length | 8.2 ft + 3.0 ft (2.5 m + 0.9 m) |
| Intended Use | Monitoring |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Physio-Control | Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Physio-Control | 11111-000018 |
IPR Medical buys, sells, repairs, and stocks parts for 4-lead ECG cables and the patient monitors they serve. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Physio-Control, or any other manufacturer or supplier named on this page. Physio-Control, Lifepak, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Physio-Control 11111-000018 Compatible 4-Lead One-Piece ECG Cable?
The IPR Medical EC-4039RS-A is a compatible aftermarket (not OEM) 4-lead one-piece ECG cable that replaces the Physio-Control 11111-000018. It brings four snap-ended limb leads and the main cable together in one reusable assembly with AHA color coding. A defib-proof feature is listed, and the cable is intended for ECG monitoring.
Compatible Monitor Models
Select Physio-Control models appear on the compatibility list for the EC-4039RS-A, with entries for the Lifepak 11, 12, 15, 20, and 20E. Your monitor’s model should appear in the compatibility table on the Specifications tab before you place the order.
Design and Construction
All four leads are for limb placement and end in snaps, colored to the AHA code as RA white, LA black, LL red, and RL green. With a specified length of 8.2 ft + 3.0 ft (2.5 m + 0.9 m), the cable is listed as defib-proof for monitoring use. Each cable comes in its own bag and is meant for reuse once it has been cleaned between patients as facility protocol requires.
When to Replace Your 4-Lead One-Piece ECG Cable
Replace the cable when a limb lead shows intermittent signal loss, when lead-off warnings continue after the electrodes are changed, or when artifact appears every time the cable moves. Visible damage matters too: a snap that has lost its grip, a split or flattened jacket, or a monitor connector with bent pins or a cracked housing. Biomedical staff can isolate the problem by connecting a known-good cable to the same monitor and comparing the traces.
Cross Reference and Interchange Part Numbers
Physio-Control 11111-000018 is the OEM part number this cable cross-references. No aftermarket interchange numbers are listed for it, so that single OEM number is the whole cross-reference table on the Specifications tab.
Why Source Limb Lead ECG Cables from IPR Medical?
For patient monitors and infusion pumps, IPR Medical is a source for buying, selling, repairing, and stocking parts, ECG cables like this one included. The company is an ISO 9001:2015-certified independent service organization whose repair work stays in-house with its own technicians. Call 855-477-8866 with questions about the EC-4039RS-A or a repair, or browse our ECG cables and leadwires.
IPR Medical buys, sells, repairs, and stocks parts for 4-lead ECG cables and the patient monitors they serve. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Physio-Control, or any other manufacturer or supplier named on this page. Physio-Control, Lifepak, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.