Masimo LNC-4 (2017) Compatible LNCS SpO2 Patient Cable, Reusable, 3.9 ft (1.2 m)
The Masimo LNC-4 SpO2 cable 2017 compatible replacement is a reusable, aftermarket short LNCS patient cable (not OEM) that connects Masimo LNCS sensors to Masimo SET defibrillators, oximeters, and monitors, built to OEM fit, form, and function.
| SpO2 Technology | Masimo LNCS |
| Cable Length | 3.9 ft (1.2 m) |
| Lifecycle | Reusable |
Works with: Physio-Control Lifepak 11/12/15/20, Zoll E/M/R Series, Masimo Radical-7 and Rad-5/8/9/57/87, Masimo-equipped Datascope and Mindray monitors, GE Dinamap ProCare, and Welch Allyn Spot Vital Signs. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Replacement (Aftermarket, Not OEM) |
| IPR Medical SKU | SA-008RB-12LS |
| OEM Reference | Masimo 2017 (LNC-4) |
| Cable Type | SpO2 Patient / Adapter Cable |
| SpO2 Technology | Masimo LNCS |
| Cable Length | 3.9 ft (1.2 m) |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
Device must be configured with Masimo SET SpO2.
| Manufacturer | Compatible Models |
| Physio-Control | Lifepak 11, 12, 15, 20, 20E |
| Zoll | E Series, M Series, R Series |
| Masimo | Radical, Radical-7; Rad-5, Rad-5v, Rad-8, Rad-9, Rad-57, Rad-87; Pronto-7; Bitmos 901 M, 901 ML |
| Datascope | Accutorr V, Accutorr Plus (incl. Masimo Rainbow Option); EPM4; Passport 2 (Masimo Rainbow Option), Passport 2LT, Passport XG; T8; V12, V21 |
| Mindray (Masimo Option) | Accutorr V; Duo; Passport 2, Passport V; Spectrum, Spectrum OR; Trio; V12, V21 |
| GE Healthcare / Dinamap | ProCare with Masimo Pro 1000; Pro 300V2; ProCare 300, ProCare Auscultatory 400; ProSeries V2; V300 |
| Welch Allyn | Spot Vital Signs 42MTB-E1, Spot Vital Signs LXi, 45NE0-E1 LX; 53STP; Propaq CS |
| Bitmos | sat 800, sat 801, sat 805, sat 816, satPuls |
| Other | Atom V-2100G; Comen C60; Invivo Escort II OPT30 Prism; Respironics Alice 5 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Masimo | 2017 (LNC-4) |
| Physio-Control | 11171-000024 |
| Zoll | 8000-0298 |
| Draeger | MP00800 |
| DRE | 80032MOC |
| Mindray | 0012-00-1652 |
| Unimed | U704M-15R |
IPR Medical buys, sells, repairs, and stocks parts for Masimo-equipped patient monitors, pulse oximeters, and defibrillators. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Masimo LNC-4 Compatible LNCS SpO2 Patient Cable?
The Masimo LNC-4 (2017) compatible SpO2 patient cable is a reusable, aftermarket short adapter cable that connects Masimo LNCS pulse oximetry sensors to Masimo SET oximeters and to monitors and defibrillators from other manufacturers that use the Masimo SET patient cable connector. It is a compatible replacement, not an original Masimo part, and it is built to OEM fit, form, and function.
Compatible Monitor Models
This compatible cable is confirmed for use with Physio-Control Lifepak 11, 12, 15, 20, and 20E defibrillator/monitors, Zoll E, M, and R Series defibrillators, and Masimo Radical, Radical-7, Rad-5, Rad-5v, Rad-8, Rad-9, Rad-57, Rad-87, and Pronto-7 devices. It also fits Masimo-equipped Datascope and Mindray Accutorr, Passport, Spectrum, Duo, Trio, and V-series monitors, GE Dinamap ProCare, ProSeries, and V300 monitors, Welch Allyn Spot Vital Signs and Propaq CS monitors, and Bitmos, Atom, Comen, Invivo, and Respironics devices. The monitor must be configured with Masimo SET SpO2; see the Specifications tab for the full model list.
Design and Construction
The short 3.9 ft (1.2 m) cable is sized for defibrillators, transport monitors, and handheld or spot-check oximeters where the device stays close to the patient and excess cable would tangle or snag. The sensor end accepts Masimo LNCS sensors in adult, pediatric, infant, and neonatal sizes, in both reusable and single-patient-use styles. The cable is reusable after cleaning according to facility protocol and ships one per bag.
When to Replace Your Masimo LNCS Patient Cable
Replace the cable when the monitor shows “SpO2 sensor off,” “no cable,” “replace cable,” or cable/sensor fault messages with a known-good LNCS sensor, when saturation or pleth readings drop out as the cable is moved, or when you find a cracked jacket, a loose sensor latch, or bent or corroded connector pins. Cables on defibrillators and transport monitors are coiled, stowed, and unpacked often, so inspect the strain reliefs at both ends during routine checks.
Cross Reference and Interchange Part Numbers
This compatible Masimo LNCS patient cable, IPR Medical SKU SA-008RB-12LS, cross-references to Masimo 2017 (LNC-4), Physio-Control 11171-000024, Zoll 8000-0298, Draeger MP00800, DRE 80032MOC, and Mindray 0012-00-1652. It also interchanges with Unimed U704M-15R. For longer runs, IPR Medical also stocks the compatible Masimo LNCS patient cable in 7.9 ft (2.4 m), SKU SA-008RB-24LS, and the 9.8 ft (3.0 m) Masimo LNC-10 (1814) version, SKU SA-008RB-30LS.
Why Source SpO2 Cables from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. We carry compatible Masimo, Nellcor, and TruSignal SpO2 cables and sensors in multiple lengths for monitors, oximeters, and defibrillators, so biomedical teams can standardize sourcing at lower cost than OEM. Our team can help identify each device’s SpO2 technology and connector and support your equipment with in-house repair services.
IPR Medical buys, sells, repairs, and stocks parts for Masimo-equipped patient monitors, pulse oximeters, and defibrillators. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Masimo, or any other manufacturer or supplier named on this page. Masimo, LNCS, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.