Philips Avalon CL Wireless Ultrasound Transducer (866076)
Original price was: $1,695.00.$1,495.00Current price is: $1,495.00.The Philips Avalon CL Wireless Ultrasound Transducer (866076) is the cableless fetal heart rate transducer in the Avalon CL Fetal Transducer System — a Smart Transducer with an onboard microprocessor that captures, processes, and digitally transmits the fetal heart rate signal directly to the Avalon fetal monitor. Its seven-crystal array (six crystals arranged around the perimeter with one in the center, in equilateral triangle geometry) delivers uniform acoustic coverage and strong cardiac detection with minimal repositioning, making it especially effective for twins, triplets, and active labor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same measurement performance as wired Smart Transducers at ranges up to 100 m (300 ft) line of sight.
The 866076 supports Cross-Channel Verification (CCV) to prevent maternal-fetal heart rate confusion, Fetal Movement Profile (FMP) for high-risk pregnancy monitoring, and automatic channel assignment (FHR1/FHR2/FHR3) when multiple transducers are in use. It is watertight for underwater monitoring, weighs approximately 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic pairing and battery recharging.
IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips Avalon CL Wireless Transducer Base Station (866074)
Original price was: $2,695.00.$2,495.00Current price is: $2,495.00.The Philips Avalon CL Wireless Transducer Base Station (866074) is the hub of the Philips Avalon CL cableless fetal monitoring system — the docking station, charger, and wireless gateway that transforms a wired Avalon fetal monitor into a fully cableless L&D solution. A single 866074 base station docks up to three cableless fetal transducers (866075 Toco+ MP, 866076 Ultrasound, and 866077 ECG/IUP) plus one maternal parameters slot for an IntelliVue CL Pod or range extension module, with a total assignment capacity of four CL transducers and two CL Pods. It connects to any Philips Avalon FM20, FM30, FM40, or FM50 fetal monitor via the fetal sensor socket — or to the rear telemetry connectors on the FM40 and FM50 — and delivers a line-of-sight operating range of up to 100 m (300 ft).
Docked transducers and pods are assigned and recharged automatically, so labor teams can grab a patient-ready device and apply it with no setup. The 866074 base station is required for all Avalon CL transducers and pods. IPR Medical sells, buys, repairs, and stocks parts for the Philips Avalon CL system — including base stations, transducers, antennas, power supplies, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3012A Hemodynamic Extension | Option C00, Dual Pressure & Dual Temperature
Original price was: $1,295.00.$995.00Current price is: $995.00.The Philips IntelliVue M3012A (Option C00) is the base configuration of the IntelliVue Hemodynamic Measurement Server Extension. It attaches directly to the Philips M3001A Multi-Measurement Module to add two independent invasive pressure channels, two independent temperature channels, and one combined pressure/temperature connector — enabling simultaneous hemodynamic pressure and temperature monitoring that the M3001A’s single shared C06 or C18 connector cannot provide on its own. The M3012A C00 is the standard hemodynamic expansion unit for ICU, cardiovascular step-down, and critical care transport environments where multiple pressure lines, bilateral temperature monitoring, or both are required alongside the M3001A’s core vital signs parameter set, but cardiac output measurement is not part of the clinical protocol.
IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3012A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A04C18, 12-Lead ECG, Nellcor OxiMax SpO2, IBP & Temp
Original price was: $1,995.00.$1,795.00Current price is: $1,795.00.The Philips IntelliVue M3001A (Option A04C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module for facilities using Nellcor OxiMax sensors on the newer Hardware Revision C platform. The C18 option combines both extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG using 5 electrodes, QT/QTc monitoring, respiration, Nellcor OxiMax-compatible SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration. The A04C18 is the Hardware Revision C equivalent of the A02C18: clinically identical in every measurement capability with OxiMax sensors connecting through the M1943NL adapter cable, built on the newer internal platform identified by serial number prefixes DE610, DE632, DE717, and DE907. As with all M3001A C18 configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.
Part Number / Option
M3001A, Option A04C18Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)SpO2 Technology
Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connectionHardware Generation
Revision C — serial number prefixes DE610, DE632, DE717, DE907; newer platform vs. A02C1812-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedIBP / Temp Port
One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this portHost Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A04C12, 12-Lead ECG & Nellcor OxiMax SpO2
Original price was: $1,995.00.$1,795.00Current price is: $1,795.00.The Philips IntelliVue M3001A (Option A04C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module for facilities using Nellcor OxiMax sensors on the newer Hardware Revision C platform. Building on the A04 standard package — ECG, arrhythmia, ST, respiration, Nellcor OxiMax-compatible SpO2, and oscillometric NBP — the C12 option adds conventional 12-lead ECG capture and EASI-derived 12-lead ECG using only 5 electrodes. The A04C12 is the Hardware Revision C equivalent of the A02C12: clinically identical in 12-lead ECG capability and OxiMax sensor interface, built on the newer internal platform identified by serial number prefixes DE610, DE632, DE717, and DE907. OxiMax sensors connect through the M1943NL adapter cable as with all A02 and A04 configurations. The A04C12 is the correct choice for facilities requiring documented 12-lead ECG alongside continuous monitoring in a Nellcor OxiMax environment, without invasive pressure or temperature in the MMS module.
Part Number / Option
M3001A, Option A04C12Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric)SpO2 Technology
Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connectionHardware Generation
Revision C — serial number prefixes DE610, DE632, DE717, DE907; newer platform vs. A02C1212-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedInvasive Pressure / Temperature
Not included in Option A04C12 — available with Option A04C18Host Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A03C18, 12-Lead ECG, Masimo SET SpO2, IBP & Temp
Original price was: $1,595.00.$1,395.00Current price is: $1,395.00.The Philips IntelliVue M3001A (Option A03C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. The C18 option combines both extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG using 5 electrodes, QT/QTc monitoring, respiration, Masimo SET SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration with Masimo LNCS sensor compatibility. The A03C18 is the direct Masimo SET equivalent of the A01C18 and A02C18: clinically identical in every measurement capability, with Masimo LNCS sensors connecting via the Masimo LNC MP-10 dual-key patient cable (part 2281). As with all M3001A C18 configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.
Part Number / Option
M3001A, Option A03C18Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Masimo SET SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)SpO2 Technology
Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection12-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedIBP / Temp Port
One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this portHost Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A03C12, 12-Lead ECG & Masimo SET SpO2
Original price was: $1,595.00.$1,395.00Current price is: $1,395.00.The Philips IntelliVue M3001A (Option A03C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. Building on the A03 standard package — ECG, arrhythmia, ST, respiration, Masimo SET SpO2, and oscillometric NBP — the C12 option adds conventional 12-lead ECG capture and EASI-derived 12-lead ECG using only 5 electrodes. The A03C12 is the Masimo SET equivalent of the A01C12 and A02C12: clinically identical in 12-lead ECG capability and overall parameter set, with the SpO2 interface built around a dedicated Masimo SET circuit, and Masimo LNCS sensors connecting via the Masimo LNC MP-10 dual-key patient cable (part 2281). It is the correct choice for facilities that require documented, diagnostic-quality 12-lead ECG recordings alongside continuous monitoring and are standardized on Masimo LNCS sensors, but do not need invasive pressure or temperature within the MMS module itself.
Part Number / Option
M3001A, Option A03C12Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Masimo SET SpO2, NBP (oscillometric)SpO2 Technology
Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection12-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedInvasive Pressure / Temperature
Not included in Option A03C12 — available with Option A03C18Host Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A02C18, 12-Lead ECG, Nellcor OxiMax SpO2, IBP & Temp
Original price was: $1,095.00.$995.00Current price is: $995.00.The Philips IntelliVue M3001A (Option A02C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Nellcor OxiMax sensors. The C18 option combines both extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG using 5 electrodes, QT/QTc monitoring, respiration, Nellcor OxiMax-compatible SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration with OxiMax sensor compatibility. The A02C18 is the direct Nellcor OxiMax equivalent of the A01C18: clinically identical in every measurement capability, with OxiMax sensors connecting through the M1943NL adapter cable. As with all M3001A C-option configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.
Part Number / Option
M3001A, Option A02C18Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)SpO2 Technology
Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connection12-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedIBP / Temp Port
One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this portHost Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A02C12, 12-Lead ECG & Nellcor OxiMax SpO2
Original price was: $1,095.00.$995.00Current price is: $995.00.The Philips IntelliVue M3001A (Option A02C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Nellcor OxiMax sensors. Building on the A02 standard package — ECG, arrhythmia, ST, respiration, Nellcor OxiMax-compatible SpO2, and oscillometric NBP — the C12 option adds conventional 12-lead ECG capture and EASI-derived 12-lead ECG using only 5 electrodes. The A02C12 is clinically identical to the A01C12 in every respect except that the SpO2 interface uses a dedicated OxiMax-compatible circuit rather than Philips FAST SpO2, and OxiMax sensors connect through the M1943NL adapter cable rather than directly to the module’s SpO2 port. It is the correct choice for facilities that require documented, diagnostic-quality 12-lead ECG recordings alongside continuous monitoring and are standardized on Nellcor OxiMax sensors, but do not need invasive pressure or temperature within the MMS module itself.
Part Number / Option
M3001A, Option A02C12Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric)SpO2 Technology
Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connection12-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedInvasive Pressure / Temperature
Not included in Option A02C12 — available with Option A02C18Host Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A01C12, 12-Lead ECG & FAST SpO2
Original price was: $1,095.00.$995.00Current price is: $995.00.The Philips IntelliVue M3001A (Option A01C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module with Philips FAST SpO2. Building on the A01 standard package — ECG, arrhythmia, ST, respiration, FAST SpO2, and oscillometric NBP — the C12 option adds conventional 12-lead ECG capture capability and EASI-derived 12-lead ECG using only 5 electrodes. The A01C12 is the correct choice for facilities that require diagnostic-quality 12-lead ECG at the bedside alongside continuous monitoring but do not need invasive pressure or temperature measurement in the MMS module itself. It is widely deployed in step-down units, telemetry floors, cardiac monitoring environments, and pre-/post-procedure areas where 12-lead ECG documentation is a standard clinical workflow. As with all M3001A variants, patient demographics, trend data, and measurement settings are stored within the module and travel with the patient between IntelliVue host monitors.
Part Number / Option
M3001A, Option A01C12Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Philips FAST SpO2, NBP (oscillometric)SpO2 Technology
Philips FAST SpO2 — compatible with Nellcor OxiMax sensors12-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedInvasive Pressure / Temperature
Not included in Option A01C12 — available with Option A01C18Host Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A01C18, 12-Lead ECG, FAST SpO2, IBP & Temp
Original price was: $1,095.00.$995.00Current price is: $995.00.The Philips IntelliVue M3001A (Option A01C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module with Philips FAST SpO2. The C18 option combines two extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG, respiration, Philips FAST SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration. The A01C18 is the configuration of choice for cardiovascular ICUs, cardiac catheterization labs, ORs, and transport environments where diagnostic-quality 12-lead ECG and hemodynamic monitoring are required alongside the full core vital signs package. As with all M3001A C-option configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.
Part Number / Option
M3001A, Option A01C18Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Philips FAST SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)SpO2 Technology
Philips FAST SpO2 — compatible with Nellcor OxiMax sensors12-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedIBP / Temp Port
One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this portHost Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A04C06, Nellcor OxiMax SpO2, IBP & Temp
Original price was: $1,295.00.$1,095.00Current price is: $1,095.00.The Philips IntelliVue M3001A (Option A04C06) is the extended-measurement, newer-hardware-generation configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Nellcor OxiMax sensors. Building on the A04 standard package — ECG, arrhythmia, ST, respiration, Nellcor OxiMax-compatible SpO2, and oscillometric NBP — the C06 option adds a combined invasive pressure and temperature connector, enabling the module to support either invasive blood pressure monitoring or temperature measurement alongside the full core parameter set. The A04C06 is the Hardware Revision C equivalent of the A02C06: clinically identical in measurement capability and OxiMax sensor compatibility, but built on the newer internal platform identified by serial number prefixes DE610, DE632, DE717, and DE907. As with all M3001A C06 configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously. Patient demographics, trend data, and measurement settings are stored in the module itself and travel with the patient between IntelliVue host monitors.
Part Number / Option
M3001A, Option A04C06Parameters Monitored
ECG (3/5-lead), Arrhythmia, ST, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)SpO2 Technology
Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connectionHardware Generation
Revision C — serial number prefixes DE610, DE632, DE717, DE907; newer platform vs. A02C06IBP / Temp Port
One combined connector — supports invasive pressure transducer OR temperature probe; pressure and temperature cannot be used simultaneously on this portHost Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.