Philips IntelliVue M3001A Multi-Measurement Module | Option A03C18, 12-Lead ECG, Masimo SET SpO2, IBP & Temp
Original price was: $1,595.00.$1,395.00Current price is: $1,395.00.The Philips IntelliVue M3001A (Option A03C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. The C18 option combines both extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG using 5 electrodes, QT/QTc monitoring, respiration, Masimo SET SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration with Masimo LNCS sensor compatibility. The A03C18 is the direct Masimo SET equivalent of the A01C18 and A02C18: clinically identical in every measurement capability, with Masimo LNCS sensors connecting via the Masimo LNC MP-10 dual-key patient cable (part 2281). As with all M3001A C18 configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.
Part Number / Option
M3001A, Option A03C18Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Masimo SET SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)SpO2 Technology
Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection12-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedIBP / Temp Port
One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this portHost Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips Avalon Ultrasound Fetal Transducer
$1,475.00The Philips Avalon Ultrasound Fetal Transducer is a state-of-the-art device designed to deliver precise and continuous monitoring of fetal heart rate and activity. This advanced transducer leverages cutting-edge ultrasound technology to ensure accurate and reliable data, which is crucial for making informed clinical decisions during labor and delivery. Its ergonomic design and lightweight construction ensure patient comfort and ease of use for healthcare providers. The Philips Avalon Ultrasound Fetal Transducer integrates seamlessly with existing Philips fetal monitoring systems, providing a cohesive and efficient workflow in maternity wards. The device features a durable, high-quality build, ensuring consistent performance even in the most demanding clinical settings. Real-time, clear displays and alerts keep healthcare providers informed of any changes in fetal status, allowing for timely interventions. The transducer’s intuitive interface simplifies setup and operation, reducing training time and enhancing overall efficiency. Invest in the Philips Avalon Ultrasound Fetal Transducer for unparalleled accuracy, reliability, and comfort in fetal monitoring.
Brand new units may be available. Please contact us directly for more information.
-
Philips Avalon Toco+ MP Fetal Transducer (M2735A) | DECG/MECG/IUP
$1,495.00The Philips Avalon Toco+ MP Transducer (M2735A) is the most versatile wired Smart Transducer in the Avalon family — it measures uterine activity via external Toco, captures maternal pulse with built-in Smart Pulse, and accepts adapter cables for direct fetal ECG (DECG), maternal ECG (MECG), or intrauterine pressure (IUP). One transducer covers four measurement modes, which is why labor and delivery floors keep the M2735A on hand even when most patients are monitored externally.
The Toco+ MP connects to any of the four fetal sensor sockets on Avalon FM20, FM30, FM40, or FM50 monitors via a standard D-shaped connector. Smart Pulse is always active when the transducer is applied, feeding maternal pulse into the monitor’s Cross-Channel Verification (CCV) feature to reduce the risk of mistaking maternal pulse for fetal heart rate. When DECG, MECG, or IUP monitoring is needed, the user simply plugs the appropriate adapter cable into the transducer’s auxiliary connector — the monitor automatically detects the mode.
OEM Part Number
M2735A (989803143681)Measurements
Toco, Smart Pulse, DECG, MECG, IUPCompatible Monitors
Avalon FM20, FM30, FM40, FM50Connector
D-shaped (plug-and-play to any fetal sensor socket)Auxiliary Connector
7-pin D-type for DECG/MECG/IUP adapter cablesSmart Pulse
Built-in, no separate SpO2 or MECG sensor requiredIPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Toco+ MP Transducer (M2735A). Contact us at 855-477-8866 or cs@iprmed.com.
Also available from IPR Medical:
Philips M2734A / M2734B Smart Toco MP Transducer — wired external Toco with Smart Pulse |
Philips Avalon Ultrasound Fetal Transducer (M2736A) — wired US transducer for external FHR |
Philips Avalon CL Wireless Toco+ MP (866075) — cableless equivalent |
Philips Avalon CL Wireless ECG/IUP (866077) — cableless DECG/MECG/IUP |
Philips Avalon FM50 Fetal Monitor — host monitor -
Philips Avalon CL Wireless Ultrasound Transducer (866076)
Original price was: $1,695.00.$1,495.00Current price is: $1,495.00.The Philips Avalon CL Wireless Ultrasound Transducer (866076) is the cableless fetal heart rate transducer in the Avalon CL Fetal Transducer System — a Smart Transducer with an onboard microprocessor that captures, processes, and digitally transmits the fetal heart rate signal directly to the Avalon fetal monitor. Its seven-crystal array (six crystals arranged around the perimeter with one in the center, in equilateral triangle geometry) delivers uniform acoustic coverage and strong cardiac detection with minimal repositioning, making it especially effective for twins, triplets, and active labor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same measurement performance as wired Smart Transducers at ranges up to 100 m (300 ft) line of sight.
The 866076 supports Cross-Channel Verification (CCV) to prevent maternal-fetal heart rate confusion, Fetal Movement Profile (FMP) for high-risk pregnancy monitoring, and automatic channel assignment (FHR1/FHR2/FHR3) when multiple transducers are in use. It is watertight for underwater monitoring, weighs approximately 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic pairing and battery recharging.
IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A04C12, 12-Lead ECG & Nellcor OxiMax SpO2
Original price was: $1,995.00.$1,795.00Current price is: $1,795.00.The Philips IntelliVue M3001A (Option A04C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module for facilities using Nellcor OxiMax sensors on the newer Hardware Revision C platform. Building on the A04 standard package — ECG, arrhythmia, ST, respiration, Nellcor OxiMax-compatible SpO2, and oscillometric NBP — the C12 option adds conventional 12-lead ECG capture and EASI-derived 12-lead ECG using only 5 electrodes. The A04C12 is the Hardware Revision C equivalent of the A02C12: clinically identical in 12-lead ECG capability and OxiMax sensor interface, built on the newer internal platform identified by serial number prefixes DE610, DE632, DE717, and DE907. OxiMax sensors connect through the M1943NL adapter cable as with all A02 and A04 configurations. The A04C12 is the correct choice for facilities requiring documented 12-lead ECG alongside continuous monitoring in a Nellcor OxiMax environment, without invasive pressure or temperature in the MMS module.
Part Number / Option
M3001A, Option A04C12Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric)SpO2 Technology
Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connectionHardware Generation
Revision C — serial number prefixes DE610, DE632, DE717, DE907; newer platform vs. A02C1212-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedInvasive Pressure / Temperature
Not included in Option A04C12 — available with Option A04C18Host Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A04C18, 12-Lead ECG, Nellcor OxiMax SpO2, IBP & Temp
Original price was: $1,995.00.$1,795.00Current price is: $1,795.00.The Philips IntelliVue M3001A (Option A04C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module for facilities using Nellcor OxiMax sensors on the newer Hardware Revision C platform. The C18 option combines both extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG using 5 electrodes, QT/QTc monitoring, respiration, Nellcor OxiMax-compatible SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration. The A04C18 is the Hardware Revision C equivalent of the A02C18: clinically identical in every measurement capability with OxiMax sensors connecting through the M1943NL adapter cable, built on the newer internal platform identified by serial number prefixes DE610, DE632, DE717, and DE907. As with all M3001A C18 configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.
Part Number / Option
M3001A, Option A04C18Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)SpO2 Technology
Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connectionHardware Generation
Revision C — serial number prefixes DE610, DE632, DE717, DE907; newer platform vs. A02C1812-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedIBP / Temp Port
One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this portHost Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips Avalon CL Wireless Toco+ MP Transducer (866075)
$1,995.00The Philips Avalon CL Wireless Toco+ MP Transducer (866075) is the cableless uterine activity transducer in the Avalon CL Fetal Transducer System — measuring uterine contractions via external Toco while simultaneously capturing maternal pulse through integrated Smart Pulse technology. It also includes a multi-purpose connector that accepts maternal ECG, fetal ECG (DECG), or intrauterine pressure (IUP) sensors, making the 866075 one of the most versatile transducers on the L&D floor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same performance as wired Smart Transducers while letting mothers walk, shower, or reposition during labor at ranges up to 100 m (300 ft) line of sight.
The 866075 is watertight for underwater monitoring, weighs only about 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic pairing and battery recharging.
IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips Avalon Ultrasound Transducer
$1,995.00The Avalon Ultrasound system by Philips is a top-tier solution designed for precise and reliable fetal and maternal monitoring. Featuring advanced ultrasound technology, it ensures accurate and continuous monitoring of fetal heart rate and uterine activity, providing critical insights for informed clinical decisions. Its user-friendly interface and intuitive controls make setup and operation straightforward, allowing healthcare professionals to focus on patient care. The Avalon Ultrasound system boasts seamless integration with existing hospital networks, enhancing workflow efficiency and enabling real-time data sharing. Its compact, ergonomic design ensures easy portability and adaptability to various clinical settings, from labor and delivery rooms to intensive care units. Constructed with high-quality materials, the system promises durability and consistent performance even in demanding environments. Advanced safety features and comprehensive monitoring capabilities make it an indispensable tool for ensuring the well-being of both mother and baby. Invest in the Philips Avalon Ultrasound system for unparalleled accuracy, efficiency, and reliability in fetal and maternal healthcare.
Brand new units may be available. Please contact us directly for more information.
-
Philips IntelliVue MP50 Patient Monitor | Touchscreen, 12-Lead ECG
Original price was: $2,595.00.$2,395.00Current price is: $2,395.00.The Philips IntelliVue MP50 is a 12-inch touchscreen, multi-parameter patient monitor built for intermediate care, transport, and general floor environments. Part of Philips’ widely deployed IntelliVue platform, the MP50 shares a common user interface and modular architecture with the full IntelliVue family — from the MP2 through the MP90 — making it a familiar, interoperable choice for facilities already invested in the ecosystem. Its combination of portability, extensive parameter support via plug-and-play MMS modules, and full IntelliVue network integration makes it one of the most versatile monitors in its class.
Display
12″ color LCD TFT, SVGA resolution, resistive touchscreenWaveforms
Up to 6 simultaneous; 12 real-time ECG waves for 12-leadParameters Monitored
ECG, SpO2, NIBP, IBP, Respiration, Temp, CO2, Cardiac Output, BIS, EEG, NMT (via modules)Patient Population
Adult, Pediatric, NeonatalBattery / Portability
4–5 hours runtime; designed for in-hospital transportConnectivity
Wired LAN and IEEE 802.11 a/b/g wireless; IntelliVue portal technologyNotable Features
Touchscreen (MP50-exclusive in MP40/50 family), SmartKeys, Event Surveillance, Drug Calculator, 10 preset screen profilesIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue MP50. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips Avalon FM50 Fetal Monitor | Intrapartum, DECG & IUP
$2,495.00The Philips Avalon FM50 is an intrapartum fetal/maternal monitor for labor and delivery rooms and antepartum testing areas, combining external ultrasound and Toco monitoring with internal direct fetal ECG (DECG) and intrauterine pressure (IUP). It monitors singletons, twins, and optionally triplets on one 6.5-inch color touchscreen, prints to a built-in thermal trace recorder, and connects to Philips OB TraceVue and IntelliSpace Perinatal over LAN.
Display
6.5-inch color touchscreen; VGA output for an external displayFetal Parameters
Ultrasound FHR (twins standard, triplets optional), fetal movement profile, DECG, Toco, IUPMaternal Parameters
MECG heart rate and wave, Smart Pulse from Toco; NIBP, SpO₂, and tympanic temperature by optionSignal Verification
Cross-channel verification (automated coincidence detection)Recorder
Built-in thermal array recorder, Z-fold paper, 1, 2, or 3 cm/minConnectivity
LAN/RS232 to OB TraceVue or IntelliSpace Perinatal; rear connection for Avalon CL or Avalon CTS cableless systemsIPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon FM50 Fetal Monitor. Contact us at 855-477-8866 or cs@iprmed.com.
Also available from IPR Medical:
Philips Avalon CL Base Station — cableless transducer base station for Avalon fetal monitors |
Philips Avalon CL Toco+ MP Transducer — cableless Toco with Smart Pulse |
Philips Avalon CL Ultrasound Transducer — cableless fetal heart rate |
Philips Avalon CL ECG/IUP Transducer — cableless DECG, MECG, and IUP -
Philips Avalon CL Wireless Transducer Base Station (866074)
Original price was: $2,695.00.$2,495.00Current price is: $2,495.00.The Philips Avalon CL Wireless Transducer Base Station (866074) is the hub of the Philips Avalon CL cableless fetal monitoring system — the docking station, charger, and wireless gateway that transforms a wired Avalon fetal monitor into a fully cableless L&D solution. A single 866074 base station docks up to three cableless fetal transducers (866075 Toco+ MP, 866076 Ultrasound, and 866077 ECG/IUP) plus one maternal parameters slot for an IntelliVue CL Pod or range extension module, with a total assignment capacity of four CL transducers and two CL Pods. It connects to any Philips Avalon FM20, FM30, FM40, or FM50 fetal monitor via the fetal sensor socket — or to the rear telemetry connectors on the FM40 and FM50 — and delivers a line-of-sight operating range of up to 100 m (300 ft).
Docked transducers and pods are assigned and recharged automatically, so labor teams can grab a patient-ready device and apply it with no setup. The 866074 base station is required for all Avalon CL transducers and pods. IPR Medical sells, buys, repairs, and stocks parts for the Philips Avalon CL system — including base stations, transducers, antennas, power supplies, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.