Philips CL Wireless ECG / IUP Transducer (866077)
$1,195.00The Philips Avalon CL Wireless ECG/IUP Transducer (866077) is a cableless, battery-powered transducer that captures maternal ECG, fetal ECG (DECG), and intrauterine pressure (IUP) on a single device — giving labor and delivery teams three internal and maternal measurements without tethering the patient to the monitor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same measurement performance as wired Smart Transducers while letting mothers walk, shower, or reposition during labor with an operating range of up to 100 m (300 ft) line of sight.
The 866077 is watertight for underwater monitoring, weighs only 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic assignment and battery recharging — no patient cables, no separate charger. IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips Compatible M1355A External Toco Transducer | Series 50
$295.00The Philips M1355A is the external tocodynamometer (Toco) transducer used with the Philips Series 50 family of fetal monitors (cardiotocographs), including the Series 50 A (M1351A) and the Series 50 IP-2 (M1353A). It uses a strain-gauge–based pressure sensor strapped over the fundus of the maternal abdomen to detect the duration, frequency, and relative intensity of uterine contractions, and it pairs with the M1356A ultrasound transducer to provide a complete external CTG trace.
Device Type
External tocodynamometer (Toco) transducer for non-invasive uterine activity monitoringCompatible Monitors
Philips Series 50 A (M1351A Single and Twins), Series 50 IP-2 (M1353A), and earlier Philips/HP M1350 fetal monitorsPatient Population
Antepartum and intrapartum monitoring of uterine activityConnector
Keyed round multi-pin connector to the dedicated Toco socket on the Series 50 monitorMounting
Snap-clip to M1562A reusable transducer belt; transducer knob adapter (M1356-43201) optionalHousing Color Variants
Brown (M1355-60001) and Blue (M1355-60011) — color matches monitor housingIPR Medical buys, sells, repairs, and stocks parts for the Philips M1355A external Toco transducer. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips Compatible M1356A Fetal Ultrasound Transducer | Series 50
$295.00This is an aftermarket-compatible wide-beam Doppler ultrasound transducer designed to function as a direct replacement for the M1356A fetal ultrasound transducer used with the Philips Series 50 family of fetal monitors (cardiotocographs), including the Series 50 A (M1351A) and the Series 50 IP-2 (M1353A). It is applied externally to the maternal abdomen and uses a wide-beam Doppler ultrasound element to detect fetal heart sounds, which the host monitor then processes through its auto-correlation algorithm to produce a continuous fetal heart rate (FHR) trace. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.
Device Type
Aftermarket-compatible external wide-beam Doppler ultrasound transducer for fetal heart rate (FHR)Replaces / Cross Reference
M1356A fetal ultrasound transducer (also referenced as part 80310120)Compatible Monitors
Philips Series 50 A (M1351A Single and Dual Ultrasound Twins), Series 50 IP-2 (M1353A), and earlier Philips/HP M1350 series fetal monitorsPatient Population
Antepartum (from approximately 20–25 weeks gestation) and intrapartum monitoringConnector
Keyed round multi-pin connector compatible with the US, US1, or US2/ECG socket on the Series 50 monitorMounting
Snap-clip belt fixing onto compatible reusable fetal monitoring belts (e.g., M1562A); transducer knob adapter (M1356-43201) optionalIPR Medical buys, sells, repairs, and stocks parts for the Philips Series 50 fetal monitor family, including aftermarket-compatible fetal ultrasound transducers for the M1356A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips Compatible Wireless Toco Transducer for Philips Avalon | M2725A
$1,395.00This is an aftermarket-compatible cordless Toco transducer designed to function as a direct replacement for the M2725A wireless Toco fetal transducer used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50) when paired with the Avalon CTS cordless transducer base station (M2720A). It uses a strain-gauge pressure sensor to detect uterine activity by evaluating the hardness of the maternal abdomen during labor, transmitting the signal wirelessly to the CTS base so the patient retains freedom of movement during antepartum testing and labor and delivery. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.
Device Type
Aftermarket-compatible cordless (wireless) external Toco transducer for fetal/maternal monitoringReplaces / Cross Reference
M2725A cordless Toco transducer (also referenced as part 862488)Compatible Monitors
Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) — used together with the Avalon CTS base station (M2720A)Patient Population
Antepartum testing and labor and delivery; ambulatory patients within the CTS base station’s coverage areaKey Features
Cordless operation, lightweight handheld form factor, waterproof housing for shower/bath use during labor, on-board status indicatorsMounting
Snap-clip belt fixing onto compatible reusable or waterproof fetal monitoring beltsIPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Cordless Transducer System (CTS), including aftermarket-compatible wireless Toco transducers for the M2725A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips M2734A / M2734B Smart Toco MP Transducer | Avalon
$1,395.00The Philips M2734A and M2734B are wired Smart Toco MP transducers used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50). They combine two parameters in a single sensor — external uterine activity (Toco) and maternal pulse (MP) — and enable the Avalon platform’s Smart Pulse automated coincidence detection, which cross-checks the maternal pulse against the fetal heart rate to confirm the host monitor is not inadvertently tracking maternal heart rate as fetal. The M2734B is the successor revision to the M2734A and is functionally interchangeable on the Avalon Toco socket; both are auto-identifying via the Smart-interface (pink) connector and carry internal calibration data storage.
Device Type
Wired dual-parameter Smart Toco MP transducer (uterine activity + maternal pulse)Models
M2734A (original Smart Toco MP) and M2734B (successor revision); both share the same role and Avalon socketCompatible Monitors
Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) at supported software revisionsConnector
Wired Smart-interface (pink) connector to the dedicated Toco socket on the Avalon host monitorKey Features
Dual-parameter Toco + maternal pulse, Smart Pulse coincidence detection, waterproof housing for shower/bath use, latex-free, auto-identification, internal calibration data storagePatient Population
Antepartum testing and labor and deliveryIPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon fetal monitor family, including the M2734A and M2734B Smart Toco MP transducers. Contact us at 855-477-8866 or cs@iprmed.com.