  • Philips CL Wireless ECG / IUP Transducer (866077)

    $1,195.00

    The Philips Avalon CL Wireless ECG/IUP Transducer (866077) is a cableless, battery-powered transducer that captures maternal ECG, fetal ECG (DECG), and intrauterine pressure (IUP) on a single device — giving labor and delivery teams three internal and maternal measurements without tethering the patient to the monitor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same measurement performance as wired Smart Transducers while letting mothers walk, shower, or reposition during labor with an operating range of up to 100 m (300 ft) line of sight.

    The 866077 is watertight for underwater monitoring, weighs only 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic assignment and battery recharging — no patient cables, no separate charger. IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips Compatible M1355A External Toco Transducer | Series 50

    $295.00

    The Philips M1355A is the external tocodynamometer (Toco) transducer used with the Philips Series 50 family of fetal monitors (cardiotocographs), including the Series 50 A (M1351A) and the Series 50 IP-2 (M1353A). It uses a strain-gauge–based pressure sensor strapped over the fundus of the maternal abdomen to detect the duration, frequency, and relative intensity of uterine contractions, and it pairs with the M1356A ultrasound transducer to provide a complete external CTG trace.

    Device Type
    External tocodynamometer (Toco) transducer for non-invasive uterine activity monitoring

    Compatible Monitors
    Philips Series 50 A (M1351A Single and Twins), Series 50 IP-2 (M1353A), and earlier Philips/HP M1350 fetal monitors

    Patient Population
    Antepartum and intrapartum monitoring of uterine activity

    Connector
    Keyed round multi-pin connector to the dedicated Toco socket on the Series 50 monitor

    Mounting
    Snap-clip to M1562A reusable transducer belt; transducer knob adapter (M1356-43201) optional

    Housing Color Variants
    Brown (M1355-60001) and Blue (M1355-60011) — color matches monitor housing

    IPR Medical buys, sells, repairs, and stocks parts for the Philips M1355A external Toco transducer. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips Compatible M1356A Fetal Ultrasound Transducer | Series 50

    $295.00

    This is an aftermarket-compatible wide-beam Doppler ultrasound transducer designed to function as a direct replacement for the M1356A fetal ultrasound transducer used with the Philips Series 50 family of fetal monitors (cardiotocographs), including the Series 50 A (M1351A) and the Series 50 IP-2 (M1353A). It is applied externally to the maternal abdomen and uses a wide-beam Doppler ultrasound element to detect fetal heart sounds, which the host monitor then processes through its auto-correlation algorithm to produce a continuous fetal heart rate (FHR) trace. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.

    Device Type
    Aftermarket-compatible external wide-beam Doppler ultrasound transducer for fetal heart rate (FHR)

    Replaces / Cross Reference
    M1356A fetal ultrasound transducer (also referenced as part 80310120)

    Compatible Monitors
    Philips Series 50 A (M1351A Single and Dual Ultrasound Twins), Series 50 IP-2 (M1353A), and earlier Philips/HP M1350 series fetal monitors

    Patient Population
    Antepartum (from approximately 20–25 weeks gestation) and intrapartum monitoring

    Connector
    Keyed round multi-pin connector compatible with the US, US1, or US2/ECG socket on the Series 50 monitor

    Mounting
    Snap-clip belt fixing onto compatible reusable fetal monitoring belts (e.g., M1562A); transducer knob adapter (M1356-43201) optional

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Series 50 fetal monitor family, including aftermarket-compatible fetal ultrasound transducers for the M1356A. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips Compatible Wireless Toco Transducer for Philips Avalon | M2725A

    $1,395.00

    This is an aftermarket-compatible cordless Toco transducer designed to function as a direct replacement for the M2725A wireless Toco fetal transducer used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50) when paired with the Avalon CTS cordless transducer base station (M2720A). It uses a strain-gauge pressure sensor to detect uterine activity by evaluating the hardness of the maternal abdomen during labor, transmitting the signal wirelessly to the CTS base so the patient retains freedom of movement during antepartum testing and labor and delivery. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.

    Device Type
    Aftermarket-compatible cordless (wireless) external Toco transducer for fetal/maternal monitoring

    Replaces / Cross Reference
    M2725A cordless Toco transducer (also referenced as part 862488)

    Compatible Monitors
    Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) — used together with the Avalon CTS base station (M2720A)

    Patient Population
    Antepartum testing and labor and delivery; ambulatory patients within the CTS base station’s coverage area

    Key Features
    Cordless operation, lightweight handheld form factor, waterproof housing for shower/bath use during labor, on-board status indicators

    Mounting
    Snap-clip belt fixing onto compatible reusable or waterproof fetal monitoring belts

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Cordless Transducer System (CTS), including aftermarket-compatible wireless Toco transducers for the M2725A. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips M2734A / M2734B Smart Toco MP Transducer | Avalon

    $1,395.00

    The Philips M2734A and M2734B are wired Smart Toco MP transducers used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50). They combine two parameters in a single sensor — external uterine activity (Toco) and maternal pulse (MP) — and enable the Avalon platform’s Smart Pulse automated coincidence detection, which cross-checks the maternal pulse against the fetal heart rate to confirm the host monitor is not inadvertently tracking maternal heart rate as fetal. The M2734B is the successor revision to the M2734A and is functionally interchangeable on the Avalon Toco socket; both are auto-identifying via the Smart-interface (pink) connector and carry internal calibration data storage.

    Device Type
    Wired dual-parameter Smart Toco MP transducer (uterine activity + maternal pulse)

    Models
    M2734A (original Smart Toco MP) and M2734B (successor revision); both share the same role and Avalon socket

    Compatible Monitors
    Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) at supported software revisions

    Connector
    Wired Smart-interface (pink) connector to the dedicated Toco socket on the Avalon host monitor

    Key Features
    Dual-parameter Toco + maternal pulse, Smart Pulse coincidence detection, waterproof housing for shower/bath use, latex-free, auto-identification, internal calibration data storage

    Patient Population
    Antepartum testing and labor and delivery

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon fetal monitor family, including the M2734A and M2734B Smart Toco MP transducers. Contact us at 855-477-8866 or cs@iprmed.com.