Smiths Medical HOTLINE 3 Blood and Fluid Warmer

$695.00

The Smiths Medical HOTLINE® 3 Blood and Fluid Warmer (Model HL-390-38) — now distributed by ICU Medical — is a proven routine-flow fluid warming system designed to deliver blood and IV fluids to patients at normothermic temperatures under gravity flow conditions. The HOTLINE 3 uses a closed recirculating solution system that surrounds the sterile IV line with a continuous layer of warmed fluid, eliminating patient line cool-down from the warmer all the way to the access site. The proprietary triple-lumen tubing design keeps the infusate path warm without exposing it to any direct heating element. The HL-390-38 sets a recirculating solution temperature of 38°C, with an electronic primary control circuit that limits recirculating solution to 38°C maximum and an independent watchdog circuit that alarms and stops the pump at 39.2°C — keeping the system inherently free of hot spots. Compatible with the HOTLINE® 3 L-370 Fluid Warming Set (single-use, sold separately), the HL-390 mounts to a standard IV pole and serves operating rooms, recovery rooms, ICUs, and emergency departments handling patients at risk of hypothermia.

IPR Medical buys, sells, repairs, and stocks parts and administration sets for the HOTLINE® 3 Blood and Fluid Warmer. Contact us at 855-477-8866 or cs@iprmed.com.

SKU: smiths-medical-hotline-3-blood-fluid-warmer-hl-390 Category: Brand: ,
Send In Smiths Medical HOTLINE 3 Blood and Fluid Warmer for Repair

HOTLINE® 3 Blood and Fluid Warmer — Model HL-390-38 Specifications

The HOTLINE® 3 L-370 Fluid Warming Set is a single-use disposable sold separately and is required for operation. The HL-390 hardware is now distributed by ICU Medical following the acquisition of Smiths Medical.


Manufacturer Smiths Medical ASD, Inc. (now distributed by ICU Medical)
Model / Part Number HL-390-38 (38°C setpoint, 115V)
Also Available HL-390-40 (40°C setpoint, 115V)
Intended Use Warming blood and IV fluids for delivery at normothermic temperatures under gravity flow conditions; for use by trained medical personnel
Warming Technology Recirculating solution heating system; triple-lumen tubing surrounds IV patient line with continuously warmed solution — inherently free of hot spots
Recirculating Solution Setpoint Temperature 37.5°C ± 0.5°C (99.5°F ± 0.9°F)
Primary Temperature Control Limit 38°C maximum; electronic circuit continuously monitors recirculating solution
Secondary (Watchdog) Over-Temperature Alarm Visual and audible alarm; recirculating pump stops if temperature reaches 39.2°C — independent of primary control circuit
Flow Rate Range 50 ml/h to 5,000 ml/h (gravity flow)
Maximum Line Pressure 300 mmHg (pressure devices exceeding 300 mmHg must not be used)
Disposable Set HOTLINE® 3 L-370 Fluid Warming Set (single-use, sterile fluid path, ~20 ml priming volume, 2.4 m / 8 ft length). IPR Medical stocks L-370 sets and HOTLINE-compatible IV sets — contact us to confirm availability.
Recirculating Solution Capacity 1.4 L (0.37 gallons)
Recirculating Solution Options Distilled water; distilled water and 35% isopropyl alcohol solution (30-day change); 0.3% hydrogen peroxide solution (annual change, eliminates monthly O-ring lubrication)
Mounting IV pole clamp; maximum mounting height 107 cm (42 inches) from floor (marked on power cord)
Physical Dimensions Height: 24.1 cm (9.5 in) | Width: 23.1 cm (9.11 in) | Depth: 17.8 cm (7.0 in)
Weight (Dry) 3.5 kg (7.6 lbs)
Weight (Wet, with recirculating solution) 5.0 kg (11.0 lbs)
Power Input 115V AC; requires properly grounded hospital-grade outlet
IP Rating IPX1 — protected against vertically dripping water
Electrical Classification Class 1 Equipment, Type BF patient-applied part per IEC 60601-1
Operating Environment Temperature: 10°C to 45°C; Humidity: 10–95% RH
Storage / Transport Temperature -18°C to 60°C; Humidity: 5–90% RH
Regulatory Standards IEC 60601-1:2005 (product safety); EN 60601-1-2, FCC 47 CFR Part 15 Class B (EMC); IEC 60529 IPX1 (enclosure); ASTM F2172-02 (fluid warmers)
Contraindications Not for use warming platelets, cryo-precipitates, or granulocyte suspensions. Not for use with pressure devices generating over 300 mmHg. Not for use in MRI or X-ray environments.
Latex Status Latex-free
FDA Device Corrections FDA Class 2 recall on record for the HOTLINE 3 (recall ID 110397); additionally, Smiths Medical / ICU Medical issued a significant safety communication regarding aluminum leaching risk in HOTLINE-platform fluid warmers. See Descriptions tab for full detail, or check the FDA Medical Device Recalls Database for the most current information.

IPR Medical buys, sells, repairs, and stocks parts and IV sets for the HOTLINE® 3 Blood and Fluid Warmer. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: Smiths Medical, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Smiths Medical.

About the HOTLINE® 3 Blood and Fluid Warmer

The HOTLINE® 3 Blood and Fluid Warmer (Model HL-390-38) is a well-established routine-flow fluid warming platform from Smiths Medical — a product line now distributed by ICU Medical following its acquisition of Smiths Medical. The HL-390 is the third-generation evolution of the original HOTLINE® fluid warmer platform. It builds on its predecessor (the HL-90) with a redesigned mounting block and a new L-370 disposable set that traps recirculating solution in the tubing when disconnected, improving portability and enabling patient transfer between the OR and recovery room without losing the warming circuit. The HL-390-38 is the 38°C setpoint version operating on 115V; a 40°C setpoint version (HL-390-40) is also available. Both models are intended for use in operating rooms, ICUs, recovery rooms, and emergency departments where patients require normothermic IV or blood product delivery.


How the HOTLINE® 3 Warming System Works

The HOTLINE® 3 system works by maintaining a continuously warmed recirculating solution reservoir within the warmer unit itself. The recirculating solution is heated to a setpoint of 37.5°C (±0.5°C) and pumped through the outer lumen of the L-370 triple-lumen disposable warming set, which surrounds the sterile IV patient line. This design ensures that the infusate inside the IV line is progressively warmed along the entire 2.4-meter (8 ft) length of the warming set — all the way to the patient’s IV access site — without ever coming into direct contact with a heating surface. Because the recirculating solution completely encircles the patient line, the system is inherently free of hot spots. The primary temperature control circuit limits the recirculating solution to 38°C maximum. An independent secondary watchdog circuit provides a backup safety shutoff — it visually and audibly alarms and stops the recirculating pump if temperature climbs to 39.2°C, operating entirely independently of the primary circuit. This dual-circuit safety architecture means the IV infusate is never exposed to damaging or dangerous temperatures during normal operation.


HOTLINE® 3 Improvements Over the Original HL-90

The HL-390 platform introduced several meaningful clinical and operational improvements over the earlier HL-90 model. The redesigned mounting block and L-370 disposable connector features built-in locking tabs that secure the set with an audible click, replacing the threaded O-ring connection used in the HL-90 / L-70 system. Critically, when the L-370 set is removed from the mounting block, internal valves in the connector close automatically — trapping the recirculating solution in the tubing rather than draining back to the reservoir. This allows the patient warming line to be transferred with the patient from the operating room to recovery and reconnected to a different HL-390 warmer without interruption, something that was not possible with the earlier platform. When using the hydrogen peroxide recirculating solution protocol, the HL-390’s O-ring design eliminates the need for monthly lubrication, reducing preventive maintenance requirements from every 30 days to annually — a significant time savings for biomedical engineering teams.


Setup, Maintenance, and Service

The HOTLINE® 3 Warmer is shipped without recirculating solution; the reservoir must be filled with 1.4 liters of the appropriate recirculating solution before first use. The unit clamps to a standard IV pole and must be mounted no higher than 107 cm (42 inches) from the floor — this height is marked on the power cord for reference. Maintenance is scheduled at three frequencies: after every use (clean exterior and inspect), every 30 days (disinfect reservoir and change isopropyl alcohol solution), and every 12 months (disinfect reservoir and change to hydrogen peroxide solution, plus full alarm, temperature verification, and electrical safety tests). There are no user-serviceable parts inside the warmer; all internal service must be performed by Smiths Medical / ICU Medical or competent authorized personnel. IPR Medical’s biomedical team provides repair and calibration services for the HL-390 platform and can assist with annual verification testing support.


IV Sets and Consumables

The HOTLINE® 3 requires the L-370 HOTLINE® 3 Fluid Warming Set for each patient use. The L-370 is a single-use, sterile, latex-free disposable set with a triple-lumen design, a priming volume of approximately 20 ml, and a length of 2.4 m (8 ft). It connects to the HL-390 mounting block with a locking connector and an audible click. Optional accessories include the L-10 Gas Vent (designed to reduce microbubble outgassing when fluids are warmed), the PC-8 piggyback connector, and the YC-8 Y-connector. The HLTA-390 TEMP CHECK thermometer accessory is used for periodic verification of recirculating solution temperature calibration during annual maintenance. IPR Medical stocks L-370 sets and other HOTLINE-compatible consumables — providing a single-vendor source for both the warmer hardware and the disposable sets it requires.


FDA Device Corrections and Safety Bulletins

The FDA’s medical device database lists a Class 2 device recall for the Smiths Medical HOTLINE 3 Blood and Fluid Warmer (FDA recall ID 110397). Class 2 recalls indicate situations where use of the device may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.

Separately, Smiths Medical / ICU Medical issued a significant safety communication regarding a potential aluminum leaching risk associated with the HOTLINE® fluid warming platform and other fluid warmers that use aluminum heating elements. Under certain conditions — particularly when specific solutions or blood products are warmed at lower flow rates over extended periods — aluminum heating elements have the potential to leach aluminum ions into the heated fluid. If warmed fluid containing elevated aluminum is delivered to a patient, it could lead to aluminum toxicity. Reported potential clinical effects of aluminum toxicity include anemia, seizures, coma, and in severe cases death, though at the time of the Smiths Medical announcement, no confirmed injuries or deaths had been linked to this issue in the HOTLINE platform. Smiths Medical’s recommended mitigations focused on clinician awareness of conditions that increase leaching risk — particularly extended low-flow-rate warming of certain solutions — and conducting clinical benefit-risk analysis prior to use in high-risk populations, including infants, pregnant individuals, the elderly, and patients with poor renal function.

Safety notice: Facilities using the HOTLINE® 3 should review the Smiths Medical / ICU Medical safety communication regarding aluminum leaching risk in fluid warmers with aluminum heating elements. Consider clinical benefit-risk analysis before use in high-risk patient populations. Monitor for conditions — such as extended use at very low flow rates with certain solutions — that may increase leaching risk. For the most current correction and recall information, check the FDA’s official resources directly:

Because FDA device corrections and safety communications may be updated or expanded after the date of this listing, IPR Medical recommends that facilities also check the FDA’s official resources directly to ensure they have the most current information.


IPR Medical — Service, Parts, and IV Sets

IPR Medical buys, sells, and repairs HOTLINE® 3 Blood and Fluid Warmers and stocks compatible L-370 disposable sets and HOTLINE-compatible IV administration sets. Whether your facility needs a replacement HL-390 warmer, L-370 warming sets in volume, service support for an existing unit, or assistance with annual maintenance verification, IPR Medical’s biomedical team is ready to help.

IPR Medical buys, sells, repairs, and stocks parts and IV sets for the HOTLINE® 3 Blood and Fluid Warmer. Contact us at 855-477-8866 or cs@iprmed.com.

Repair service: IPR Medical also repairs this type of equipment in house, with a free shipping label, a free evaluation and a 90-day repair warranty. See our repair service.

Trademark Notice: Smiths Medical, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Smiths Medical.

Weight 11 lbs
Dimensions 11.5 × 10.2 × 12.5 in

Compatible Parts and Accessories

IPR Medical stocks a range of compatible parts and accessories for the HOTLINE® 3 Blood and Fluid Warmer (HL-390). The sections below cover the most commonly requested components, sourced from Smiths Medical / ICU Medical OEM documentation. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.


Fluid Warming Sets (Required Disposables)

L-370 HOTLINE® 3 Fluid Warming Set — single-use, sterile fluid path, triple-lumen design, ~20 ml priming volume, 2.4 m (8 ft) length. Dedicated to the HL-390 mounting block; not interchangeable with L-70 sets used in older HL-90 models. Required for every patient use of the HL-390.

IV Set Accessories (for use with L-370)

L-10 Gas Vent — reduces microbubble outgassing from warmed fluids before delivery to the patient. For gravity flow use only; not compatible with volumetric pumps, hand pumps, or syringes.
PC-8 Piggyback Connector — for connecting an additional IV administration set to the HOTLINE® 3 warming circuit
YC-8 Y-Connector — for splitting the warmed fluid line to two separate administration pathways

Testing and Calibration Accessories

HLTA-390 TEMP CHECK Thermometer — plugs into the socket on the right side of the HL-390; used during annual maintenance to verify recirculating solution temperature. Required for annual temperature calibration verification per the OEM maintenance protocol.

Hardware and Mounting

IV Pole Clamp Assembly Integrated IV pole clamp for mounting the HL-390 to a standard IV pole; replacement clamp assembly available — contact IPR Medical to confirm compatibility with your unit’s configuration
Reflux Plug Seals the socket on the right side of the HL-390 when no L-370 Fluid Warming Set is installed; prevents contamination of the socket between uses
Power Cord Hospital-grade grounded mains power cord, 115V; replacement available — contact IPR Medical to confirm correct cord type for your unit

IPR Medical buys, sells, repairs, and stocks parts and IV sets for the HOTLINE® 3 Blood and Fluid Warmer. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service, parts, or consumables questions.