Philips 21075A Compatible Adult General (Oral/Rectal) Temperature Probe, Dual-Pin 400 Series, 0.16 in (4.0 mm) Tip, 9.8 ft (3.0 m)
The 21075A compatible adult general (oral/rectal) temperature probe (SKU TS-PH-AG30) is a reusable aftermarket replacement (not OEM) with Dual-Pin 400 Series temperature technology, a 0.16 in (4.0 mm) probe tip, and a 9.8 ft (3.0 m) cable.
| Patient Size | Adult |
| Probe Type | General (Oral/Rectal) |
| Probe Tip | 0.16 in (4.0 mm) |
| Temperature Technology | Dual-Pin 400 Series |
| Cable Length | 9.8 ft (3.0 m) |
| Replaces | Philips 21075A |
Works with: the monitor models listed in the Specifications tab. Browse more temperature probes and cables.
IPR Medical buys, sells, repairs, and stocks parts for patient monitors and reusable temperature probes. Call 855-477-8866 or email cs@iprmed.com.
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | TS-PH-AG30 |
| Replaces OEM Part | Philips 21075A |
| Category | Cables & Sensors > Temperature |
| Product | Temperature Probe |
| Patient Size | Adult |
| Probe Type | General (Oral/Rectal) |
| Probe Tip | 0.16 in (4.0 mm) |
| Temperature Technology | Dual-Pin 400 Series |
| Cable Length | 9.8 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Contec | Patient Simulator MS400 |
| Philips | 78341A, 78342A, 78345A, 78346A, 78353A, 78353B, 78532B, 78534A, 78534B, 78834C, 862474, 862474 C3, 862478 C3, 863064, 863065, 863066, 863066 VM6, 863068, 865240, 865241, 865242, 866060, 866061, 866062, 866064, 866066, 867030, 867033, 867036, 867039, 867040, 867041, A1, A3, C1, C3, Efficia CM12, Efficia CM100, Efficia CM120, Efficia CM150, HeartStart MRx, IntelliVue MMS X2, IntelliVue MMX, IntelliVue MP2, IntelliVue MP20, IntelliVue MP20 Junior, IntelliVue MP30, IntelliVue MP40, IntelliVue MP50, IntelliVue MP60, IntelliVue MP70, IntelliVue MP80, IntelliVue MP90, IntelliVue MX100, IntelliVue MX400, IntelliVue MX430, IntelliVue MX450, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX800, IntelliVue X2, IntelliVue X3, IntelliVue XG50, M1029A, M1094A, M1094B, M1166A, M1167A, M1175A, M1177A, M1205A, M1275A, M3001A, M3001A A01C06, M3001A A01C18, M3001A A02C06, M3001A A02C18, M3001A A03C06, M3001A A03C18, M3001A A04C06, M3001A A04C18, M3002A, M3002A MMS X2, M3012A, M3015A, M3015B, M3016A, M3046A (M4 chip), M3046A M3, M3535A, M3536A, M8001A, M8002A, M8003A, M8004A, M8005A, M8007A, M8008A, M8010A, M8102A, M8102A MP2, MX Series, P60E, SureSigns VM4, SureSigns VM6, SureSigns VM8, SureSigns VS3, Viridia 24, Viridia 24C, VS1 |
| Welch Allyn | Propaq CS |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Philips | 21075A, 989803100881, 989803203571, 989803203561 |
| Unimed | THP-AG |
IPR Medical buys, sells, repairs, and stocks parts for reusable temperature probes and the patient monitors that read them. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, IntelliVue, HeartStart, Efficia, SureSigns, Viridia, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the 21075A Compatible Adult General Temperature Probe?
The IPR Medical TS-PH-AG30 is a compatible aftermarket (not OEM) adult temperature probe that replaces OEM part 21075A. Its probe type is general (oral/rectal), it uses Dual-Pin 400 Series temperature technology, and it pairs a 0.16 in (4.0 mm) probe tip with a 9.8 ft (3.0 m) cable. It is designed for repeated use across many patients.
Compatible Monitor Models
Each monitor this adult probe is listed for has its own line in the Compatible Monitor Models table on the Specifications tab. The bulk of that list comes from the OEM of part 21075A, with the Welch Allyn Propaq CS and the Contec Patient Simulator MS400 included as well. Verify your model against the table before ordering.
Design and Construction
Sized for adult patients, the TS-PH-AG30 combines a 0.16 in (4.0 mm) general-purpose tip with Dual-Pin 400 Series temperature technology and 9.8 ft (3.0 m) of cable. Each probe is supplied one per bag and is designed to be reused. Clean and disinfect it between patients according to facility protocol, and inspect the tip and cable every time it comes back into service.
When to Replace Your Adult Oral/Rectal Temperature Probe
Replace the probe when its readings drift, settle slowly, or disagree with a reference thermometer, or when the monitor reports no probe even though one is connected. Physical warning signs include a damaged or loose tip, a cut or cracked cable jacket, and bent pins at the connector. A probe that still reads poorly after a side-by-side check with a known-good probe on the same monitor should come out of service.
Cross Reference and Interchange Part Numbers
Besides OEM part 21075A, purchasing records may identify this probe by OEM number 989803203561 or 989803100881. The Specifications tab breaks out every interchange number by brand under Cross Reference / Interchange Part Numbers.
Why Source Temperature Probes from IPR Medical?
Reusable temperature probes see constant handling, so wear is expected over time. Our team buys, sells, repairs, and stocks parts for patient monitors and infusion pumps as an ISO 9001:2015-certified independent service organization, and all repairs are done in-house. Need a different probe? See our temperature probes and cables, or phone 855-477-8866 for ordering and repair help.
IPR Medical buys, sells, repairs, and stocks parts for reusable temperature probes and the patient monitors that read them. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Philips, or any other manufacturer or supplier named on this page. Philips, IntelliVue, HeartStart, Efficia, SureSigns, Viridia, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews