Skip to content
IPR Medical

Datex-Ohmeda / GE Compatible Adult Ear Clip SpO2 Sensor, 10 ft (3.0 m) – TS-E4-N

$100.00

The Datex-Ohmeda / GE Healthcare TS-E4-N compatible adult ear clip SpO2 sensor (SKU SS-014-AE30) is a reusable, aftermarket replacement (not OEM) that plugs directly into the monitor’s Datex-Ohmeda SpO2 port with no adapter cable required, built to OEM fit, form, and function.

Sensor Style Ear Clip
Patient Size Adult, over 88 lbs (40 kg)
SpO2 Technology Datex-Ohmeda
Cable Length 10 ft (3.0 m)
Lifecycle Reusable
Packaging 1 Sensor per Bag
Replaces Datex-Ohmeda / GE Healthcare TS-E4-N, Datex-Ohmeda OXY-E4-N

Works with: select Datex-Ohmeda monitors, including the S/5, AS/3, CS/3, Cardiocap/5, Cardiocap II, Light, and Satellite, as well as Aespire anesthesia platforms and M-series parameter modules. See the Specifications tab for the full list. Browse our full line of compatible SpO2 sensors and cables.

IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda and GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: datex-ohmeda-ge-spo2-sensor-ts-e4-n Categories: , Tags: , , Brand:
Send In Datex-Ohmeda / GE Compatible Adult Ear Clip SpO2 Sensor, 10 ft (3.0 m) – TS-E4-N for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Non-OEM)
IPR Medical SKU SS-014-AE30
Replaces OEM Part Number Datex-Ohmeda / GE Healthcare TS-E4-N
Sensor Style Ear Clip
Sensor Configuration Direct-Connect (No Adapter Cable Required)
Patient Size Adult (over 88 lbs / 40 kg)
Usage Reusable
Cable Length 10 ft (3.0 m)
SpO2 Technology Datex-Ohmeda
Monitor Connector 10-Pin Datex-Ohmeda Direct-Connect
Sterile No
Packaging 1 Sensor per Bag
Manufacturing Standard Produced in FDA-registered, ISO 13485:2016-certified facilities

Compatible Monitor Models

Manufacturer Compatible Models
Datex-Ohmeda Monitors S/5, S/5 with M-series modules, System 5, AS/3, AS/3 Compact, AS/3 with M-series modules, CS/3, CS/3 with M-series modules, CS/5, CS/5 Compact, Cardiocap I, Cardiocap II, Cardiocap/5, Cardiocap S/5 Light, Light Monitor
Datex-Ohmeda Anesthesia & Transport Aespire, Aespire 15, Capnomac Ultima, Oscar II, OSP-200, Satellite, Satellite Plus II, Satellite Trans, Trans Plus, TruSignal
Datex-Ohmeda Modules & Units M-ESTP, M-ESTPR, M-NESTPR, M-PRESTN, CG/2S, CH-RS, CH/2S, CH/S, ULTS00, ULTSIO, ULTSVI, ULTSVO
GE Healthcare Datex-Ohmeda S5

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Datex-Ohmeda (OEM) TS-E4-N, OXY-E4-N
GE Healthcare (OEM) TS-E4-N
AMC PR-A220-1005
Unimed U910-09
IPR Medical (Compatible) SS-014-AE30

IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda S/5, AS/3, and Cardiocap/5 patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Datex-Ohmeda, GE Healthcare, Masimo, or any other manufacturer or supplier named on this page. Datex-Ohmeda, GE Healthcare, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Datex-Ohmeda TS-E4-N Compatible SpO2 Sensor?

The SS-014-AE30 is a compatible aftermarket replacement, not an OEM part, for the Datex-Ohmeda / GE Healthcare TS-E4-N adult ear clip SpO2 sensor. It is a reusable, direct-connect pulse oximetry sensor that attaches to the earlobe. It provides continuous monitoring of oxygen saturation and pulse rate in adult patients. The cable runs directly from the ear clip to the monitor’s Datex-Ohmeda SpO2 input, so no separate adapter cable is needed. The sensor is calibrated for Datex-Ohmeda oximetry technology, so readings stay consistent with what clinicians expect from the original part.


Compatible Monitor Models

This sensor is compatible with a wide range of Datex-Ohmeda equipment. That includes the S/5 and System 5, AS/3, AS/3 Compact, CS/3, CS/5, CS/5 Compact, Cardiocap I, Cardiocap II, Cardiocap/5, Cardiocap S/5 Light, and Light Monitor, including configurations with M-series modules. It also works with the Aespire and Aespire 15 anesthesia systems. Supported transport and specialty units include the Capnomac Ultima, Oscar II, OSP-200, Satellite, Satellite Plus II, Satellite Trans, Trans Plus, and TruSignal platforms. The sensor also fits the M-ESTP, M-ESTPR, M-NESTPR, and M-PRESTN modules and the GE Healthcare Datex-Ohmeda S5. Before ordering, confirm that the monitor uses Datex-Ohmeda SpO2 technology. Masimo- or Nellcor-equipped configurations require a different sensor.


Design and Construction

The sensor uses a lightweight clip that holds the emitter and detector across the earlobe. The earlobe is a useful alternate site when finger placement is impractical. Examples include peripheral vasoconstriction, cold extremities, hand injuries or burns, excessive hand movement, and procedures where the arms are tucked or inaccessible. The sensor is rated for adult patients over 88 lbs (40 kg). The 10 ft (3.0 m) cable reaches from bedside, boom-mounted, or anesthesia-machine monitors without straining the connector. The 10-pin Datex-Ohmeda connector plugs directly into the monitor’s SpO2 port. Each sensor ships non-sterile in an individual bag and is designed to be cleaned and disinfected between patients according to facility protocol.


When to Replace Your SpO2 Sensor

Reusable ear clip sensors wear out from repeated cleaning, clip cycling, and cable flexing at the strain reliefs. Replace the sensor if the clip spring is weak or no longer holds securely on the earlobe. The same applies if the emitter or detector windows are scratched or clouded, the cable jacket is cracked or stiff, or the connector pins are bent or corroded. Performance problems are another sign of a failing sensor. Watch for persistent “sensor off,” “no signal,” or “check sensor” alarms, weak or erratic plethysmograph waveforms, and readings that change when the cable is moved. Take a sensor out of service immediately if it fails an SpO2 simulator check during preventive maintenance.


Cross Reference and Interchange Part Numbers

The SS-014-AE30 cross-references to Datex-Ohmeda OEM part numbers TS-E4-N and OXY-E4-N and to GE Healthcare part number TS-E4-N. It also cross-references to AMC PR-A220-1005 and Unimed U910-09. Materials managers can use any of these numbers to confirm fit when replacing existing stock or consolidating purchasing across facilities. A finger clip version of this sensor (OXY-F4-N compatible) is also available for primary monitoring sites.


Why Source SpO2 Sensors from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization specializing in patient monitoring and infusion equipment. We buy, sell, repair, and stock parts for Datex-Ohmeda and GE monitors, and our compatible accessories are held in inventory for fast shipping. Our in-house technical team helps biomedical departments confirm compatibility before purchase, match cross-reference numbers, and source hard-to-find parts. Beyond accessories, we also provide monitor repair, refurbishment, and equipment sales to support your fleet.

IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda S/5, AS/3, and Cardiocap/5 patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Datex-Ohmeda, GE Healthcare, Masimo, or any other manufacturer or supplier named on this page. Datex-Ohmeda, GE Healthcare, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.