IPR Medical

Siemens Compatible 3-Lead ECG Leadwire, Grabber/Pinch, AHA, Molded, 3.0 ft (0.9 m)

$40.00

The Siemens compatible 3-lead grabber/pinch ECG leadwire (SKU EL-SM3-90G-A) is a reusable aftermarket replacement (not OEM) with grabber/pinch electrode ends, limb lead placement, AHA color coding, shielded leads, and a 3.0 ft (0.9 m) length.

Lead Count 3-Lead
Electrode End Grabber/Pinch
Lead Placement Limb Lead
Feature Shielded
Cable Length 3.0 ft (0.9 m)
Replaces No single OEM part number listed

Works with: select Draeger SC models, plus the Fukuda Denshi Dynascope DS-7200. See the Specifications tab for the full list. Browse more ECG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for ECG accessories and patient monitors. Call 855-477-8866 or email cs@iprmed.com.

SKU: EL-SM3-90G-A Categories: ,
Send In Siemens Compatible 3-Lead ECG Leadwire, Grabber/Pinch, AHA, Molded, 3.0 ft (0.9 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) EL-SM3-90G-A
Replaces OEM Part No single OEM part number listed (for use with select Draeger and Fukuda Denshi models)
Category Cables & Sensors > ECG/EKG
Product ECG Leadwire
Lead Count 3-Lead
Lead Placement Limb Lead
Electrode End Grabber/Pinch
AHA/IEC Code AHA (RA white, LA black, LL red)
Distal Connector Molded
Feature Shielded
Lead Type Siemens Dual-Pin
Cable Length 3.0 ft (0.9 m)
Intended Use Monitoring
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Draeger SC 5000, SC 6000, SC 7000, SC 8000, SC 9000
Fukuda Denshi Dynascope DS-7200

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Fukuda Denshi 9D005880B, CMF-700-3FA
Unimed SM3-90P

IPR Medical buys, sells, repairs, and stocks parts for 3-lead grabber/pinch ECG leadwires and patient monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Siemens, or any other manufacturer or supplier named on this page. Siemens, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Siemens Compatible 3-Lead Grabber/Pinch ECG Leadwire?

The IPR Medical EL-SM3-90G-A is a compatible aftermarket (not OEM) 3-lead ECG leadwire for use with Siemens equipment. Rather than snaps, its three limb leads terminate in grabber/pinch electrode ends. With no Siemens OEM part number on record for it, check fit against the listed monitor models or the Fukuda Denshi reference numbers on the Specifications tab.


Compatible Monitor Models

On the compatibility side, the table names select Draeger SC models, specifically the SC 5000, SC 6000, SC 7000, SC 8000, and SC 9000, plus one Fukuda Denshi entry, the Dynascope DS-7200. Look for your exact unit in that table on the Specifications tab before ordering.


Design and Construction

Grabber/pinch ends attach each of the three limb leads at the electrode, and AHA coloring (RA white, LA black, LL red) keeps placement easy to follow. The shielded leads run 3.0 ft (0.9 m) and gather into a molded distal connector with a Siemens Dual-Pin lead type. It is a reusable monitoring leadwire, packed one per bag, that should be cleaned between patients as your facility protocol directs.


When to Replace Your 3-Lead Grabber/Pinch ECG Leadwire

Grabber jaws that have lost their spring and let the electrode slip are the most obvious cue that this leadwire has reached the end of its service life. Cracked or nicked insulation on a lead, a loose or chipped molded connector, and contacts that are bent are further reasons to pull it. If lead-off alarms or baseline noise carry on after the electrodes have been changed, try a known-good leadwire to see whether the fault moves with it.


Cross Reference and Interchange Part Numbers

No Siemens OEM part number is displayed for this leadwire. It does cross-reference to Fukuda Denshi numbers 9D005880B and CMF-700-3FA, and an aftermarket equivalent sits alongside them in the cross-reference table on the Specifications tab.


Why Source ECG Leadwires from IPR Medical?

Patient monitoring equipment and infusion pumps sit at the center of our work at IPR Medical: we buy, sell, repair, and stock parts for both. As an independent service organization with ISO 9001:2015 certification, IPR Medical completes its repairs in-house with its own technicians. Explore more ECG cables and leadwires, or reach our team at 855-477-8866.

IPR Medical buys, sells, repairs, and stocks parts for 3-lead grabber/pinch ECG leadwires and patient monitoring equipment. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Siemens, or any other manufacturer or supplier named on this page. Siemens, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.