Nellcor FLEXMAX Compatible Adult Soft Tip SpO2 Sensor, OxiMax, 3.3 ft (1.0 m)
The Nellcor FLEXMAX compatible adult soft tip SpO2 sensor (SKU SS-001XC-AS10) is a reusable aftermarket replacement (not OEM) with a 3.3 ft (1.0 m) cable, for use with Nellcor OxiMax technology.
| Sensor Type | Soft Tip |
| Patient Size | Adult |
| SpO2 Technology | Nellcor OxiMax |
| Cable Length | 3.3 ft (1.0 m) |
| Lifecycle | Reusable |
| Replaces | Nellcor FLEXMAX |
Works with: select Nellcor, GE Healthcare, Mindray / Datascope, Welch Allyn, and Nihon Kohden models, plus other brands. See the Specifications tab for the full list. Browse more SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Warranty: 6-month IPR Medical limited warranty against defects in materials and workmanship unless a different period is stated on this page (Terms §5).
Specifications
| Product Type | Compatible Aftermarket Replacement (Not OEM) |
| IPR Part Number (SKU) | SS-001XC-AS10 |
| Replaces OEM Part | Nellcor FLEXMAX |
| Category | Cables & Sensors > SpO2 |
| Sensor Type | Soft Tip |
| Patient Size | Adult |
| SpO2 Technology | Nellcor OxiMax |
| Cable Length | 3.3 ft (1.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per bag |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Artema S&W | Diascope |
| Baxter | Explorer, Monarch |
| Biolight | M8500, M9500, Q3, Q5, Q7, Q Series |
| Biosys | BPM-200, Sentry |
| Cardell | 8019-001, 8019-002, 8019-003, 9402, 9403, 9405, 9500 Series, 9500HD, MAX-12 Duo HD, Touch |
| CAS Med | 511, 740 |
| Charmcare | CX100 |
| Criticare / CSI | 506DNV3, 506DNVP3, 506LN3, 506LNP3, 506LNT3, 506LNTP3, 506LNV3, 506LNVP3, 506NV3, 506NVP3 |
| Datex-Ohmeda | AS/3, Cardiocap/5, enGuard CM5 |
| Digicare | LW600 |
| Draeger | Infinity Delta, Infinity Delta XL, Infinity Kappa, Narkomed 6400 |
| DRE | ASM 5000, Waveline, Waveline EZ MAX, Waveline Plus |
| Edan | Elite V8, iM3, iM20, iM50 |
| Fukuda Denshi | Dynascope DS-7100, Dynascope DS-8100, LX-7230N |
| GE Healthcare | 129, 188, 9710, 9720 Plus, Compact, M-NSAT Modules, MPS, Pro 400, Pro Series, ProCare, Select |
| GE Healthcare / Corometrics | 250cx |
| GE Healthcare / Critikon Dinamap | B105M, B105P, B125M, B125P, B155M, Carescape B650, Carescape V100, Compact DINAMAP MPS, Compact S, Compact TS, E-NSAT, Pro 200, Pro 300, Pro 1000, Pro 1000 V3, Pro Series V2, ProCare 200, ProCare 400, ProCare Auscultatory 400 |
| GE Healthcare / Marquette | Dash 2500, Dash 3000, Dash 4000, Dash 5000, i/9500, PDM Module, Procare B40, Solar 8000, Solar 8000M, Tram 451 |
| Goldway | Vet 420A, Vet 600A |
| Guthan | 1000 |
| Invivo | Escort II OPT30, MDE Escort Prism, Prism |
| Ivy Biomedical | 405P, 405T, 450C, 700, CM5 |
| Mediana | M20 |
| Medtronic / Covidien | Capnostream 35 (PM35MN) |
| Mindray / Datascope | Accutorr Plus, Accutorr V, BeneHeart D3, BeneView T1, BeneVision ePM 10M, BeneVision ePM 12, BeneVision ePM 12M, BeneVision ePM 15, BeneVision N1, BeneVision N12, BeneVision N12 Neo, BeneVision N15, BeneVision N17, BeneVision N22, BeneVision VS-900, cPM 8, cPM 12, DPM4, DPM5, DPM6, DPM7, Duo, ePM 10A, Expert, iMEC 5, iMEC 6, iMEC 7, iMEC 8, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iPM12VET, iPM-9800, MEC-1200Vet, Passport 2, Passport 8, Passport 12, Passport V, Passport XG, PM-9000Vet, Spectrum, Spectrum OR, Trio, V12, V-Series, VS 8, VS 8A, VS 8C, VS 9, VS 9A, VS 9C |
| Mortara | Surveyor S12/S19 |
| Nellcor | N-10, N-20, N-30, N-45, N-65, N-85, N-100, N-180, N-190, N-200, N-390, N-395, N-560, N-595, N-600, N-600x, N-3000, N-6000, NPB-40, NPB-70, NPB-75, NPB-190, NPB-195, NPB-290, NPB-295, NPB-3900, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-4000, NPB-4000C, PM10N, PM100N, PM1000N, Symphony N-3000 |
| Nihon Kohden | AY-651P, AY-653P, BSM-1700 Life Scope PT, BSM-1753, BSM-2300, BSM-2304A, BSM-3552, BSM-3572, BSM-4100, BSM-4104A, BSM-4114A, BSM-5100, BSM-6000 Series, BSM-6301A, BSM-6310K, BSM-6501K, BSM-6701K, Life Scope TR |
| Nonin | 8500, 8604, 9700 |
| Omron / Colin | BP-88, BP-88S, BP-306, BP-508, BP-808, BP-S510, Press-Mate, T105NXM |
| Oridion | Capnostream 20 |
| Philips | FM20, FM30, FM40, FM50, Heartstream XL, IntelliVue MP2, IntelliVue MP30, IntelliVue MP70, IntelliVue MX400, IntelliVue MX450, IntelliVue MX500, IntelliVue MX550, IntelliVue MX600, IntelliVue MX700, IntelliVue MX800, M1020B, M2601A, M3000A, M3001A, M3001A A02, M3001A A02C06, M3001A A02C12, M3001A A02C18, M3001A A04, M3001A A04C06, M3001A A04C12, M3001A A04C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, Prodigy, SureSigns VS2, SureSigns VS3, VS1 |
| Physio-Control | Lifepak 12, Lifepak 15 |
| Siemens | SC8000 |
| Skanray | Star 55 |
| Smiths Medical / BCI | 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, 9100, Advisor, Advisor S#155, Autocorr, Mini Torr, Mini Torr Plus, Spectro2 10, Spectro2 20, Spectro2 30 |
| Spacelabs | Telemetry Transmitter (96281), Ultraview SL, Ultraview SL 2700 |
| Suntech | 247B |
| Waltvick | Humyzin |
| Welch Allyn | 42NT0-E1 LXi, 52N Series, 53N0P, 53NT0, 53NTP, 64N Series, 65N Series, 67N Series, 68N Series, 71WT-B Connex Spot, 73C Series, 73WT-B Connex Spot, 74C Series, 1500, 4400 44WT-B, 6000 Series, 901058, Atlas 6200 Series, Connex 6000 Series, Connex Vital Signs, Encore 202EL, Propaq 106-EL, Propaq 202-EL, Propaq 204-EL, Propaq 206-EL, Propaq 244, Propaq CS, Propaq LT, Series 420, Spot Vital Signs 42MOB, Spot Vital Signs 42NOB, Spot Vital Signs 42NTB-E1 |
| Mindray / Datascope (with Nellcor SpO2 Option) | Accutorr Plus, Expert, Passport 5L, Passport EL, Passport XG |
| PaceTech (with Nellcor SpO2 Option) | Vitalmax 800 Series (black) |
| Welch Allyn (with Nellcor SpO2 Option) | Atlas |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Nellcor (Covidien) | FLEXMAX |
| Draeger | MS34677 |
| Edan | 02.01.210122-11 |
| Mediaid | CST100-3120 |
| Medlinket | 858-S0026D-S |
| Pacific Medical | NSNE200 |
| Praymed | PSC0026-S |
| Tenacore | TP1713 |
| Unimed | U403S-01XP, U403S-01P, U403NS-01P |
IPR Medical buys, sells, repairs, and stocks parts for SpO2 sensors and the patient monitors that use them. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiMax, FLEXMAX, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Nellcor FLEXMAX Compatible Soft Tip SpO2 Sensor?
The IPR Medical SS-001XC-AS10 is a compatible aftermarket (not OEM) adult soft tip SpO2 sensor that replaces the Nellcor FLEXMAX. It is a reusable sensor for adult patients, intended for use with Nellcor OxiMax technology, and it has a 3.3 ft (1.0 m) cable.
Compatible Monitor Models
Compatibility listings for this soft tip sensor include select Nellcor models such as the N-395, N-600x, and NPB-3900, select GE Healthcare Dinamap, Dash, Solar, and Carescape monitors, select Mindray and Datascope Passport, Spectrum, DPM, iMEC, and BeneVision models, and select Welch Allyn, Nihon Kohden, Smiths Medical BCI, Criticare, Draeger, Edan, and Physio-Control Lifepak models, together with models from the other brands in the table. Some Mindray / Datascope, PaceTech, and Welch Allyn models are listed for use with the Nellcor SpO2 option; those configurations have their own rows. The Compatible Monitor Models table on the Specifications tab has the complete list, so confirm your monitor and SpO2 option there before ordering.
Design and Construction
The SS-001XC-AS10 uses a soft tip sensor design sized for adults and is intended for use with Nellcor OxiMax SpO2 technology. The cable is 3.3 ft (1.0 m) long, and the sensor is packaged one per bag. Being reusable, it can be cleaned between patients in line with facility protocol and kept in service as long as it passes inspection.
When to Replace Your Soft Tip SpO2 Sensor
Replace the sensor if the soft tip is torn, cracked, or no longer fits snugly, if the cable jacket is cracked, cut, or kinked, or if the connector has bent or damaged pins. Dropouts in SpO2 readings, frequent sensor-off or low-signal alarms, and values that change when the cable is moved are other common signs of wear. A quick swap with a known-good sensor on the same monitor helps biomedical staff confirm the cause.
Cross Reference and Interchange Part Numbers
This compatible sensor replaces the Nellcor FLEXMAX and also cross-references to Draeger MS34677 and Edan 02.01.210122-11. The remaining interchange numbers are listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.
Why Source SpO2 Sensors from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps. Because our technicians repair and test monitors in-house, our team can help you pick the SpO2 sensor that fits your monitors and keep those monitors running. Explore more SpO2 sensors and cables, or call 855-477-8866 for help with ordering, repairs, or parts.
IPR Medical buys, sells, repairs, and stocks parts for SpO2 sensors and the patient monitors that use them. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiMax, FLEXMAX, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews
There are no reviews yet.


















