Nellcor SCP-10 Compatible SpO2 Adapter Cable for OxiSmart Sensors, Reusable, 7.9 ft (2.4 m)

$60.00

Nellcor SCP-10 Compatible SpO2 Adapter Cable (SKU SA-002-24) is a compatible aftermarket replacement (not OEM) for the Nellcor SCP-10. It is a reusable 7.9 ft (2.4 m) adapter cable for use with Nellcor OxiSmart SpO2 sensors.

Replaces Nellcor SCP-10
SpO2 Technology Nellcor OxiSmart
Cable Length 7.9 ft (2.4 m)
Lifecycle Reusable

Works with: select Nellcor, Mindray and Datascope, GE Healthcare Dinamap, Datex-Ohmeda, Nihon Kohden, Welch Allyn, and other monitors. See the Specifications tab for the full compatibility list.

IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: SA-002-24 Categories: , Tags: ,
Send In Nellcor SCP-10 Compatible SpO2 Adapter Cable for OxiSmart Sensors, Reusable, 7.9 ft (2.4 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) SA-002-24
Replaces OEM Part Nellcor SCP-10
Category Cables & Sensors > SpO2
Product SpO2 Adapter Cable (for use with OxiSmart Sensors)
SpO2 Technology Nellcor OxiSmart
Cable Length 7.9 ft (2.4 m)
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Bitmos sat 800, sat 801, sat 805, sat 816, satPuls
Criticare / CSI 506DNV3, 506DNVP3, 506LNV3, 506LNVP3, 506NV3, 506NVP3
Datex-Ohmeda AS/3, CS/3, Cardiocap/5, S/5, enGuard CM5
Digicare LW600
DRE Waveline
Fukuda Denshi Dynascope DS-7100
GE Healthcare / Critikon Dinamap Carescape B650, Carescape V100, E-NSAT, M-NSAT Module, Pro 200, Pro 300, Pro 300V2, Pro 400, Pro 1000, Pro 1000 V3, Pro Series, Pro Series V2, ProCare, ProCare 200, ProCare 300, ProCare 400, ProCare Auscultatory 400, V300
Invivo 200, Escort II OPT30 Prism, MDE Escort Prism
Mediana YM6000
Cardell 9403, 9500HD
Mindray / Datascope Accutorr Plus, Accutorr V, Duo, EPM4, Passport 2, Passport 2LT, Passport V, Passport XG, Spectrum, Spectrum OR, T8, Trio, V12, V21
Mindray / Datascope (with Nellcor SpO2 Option) Accutorr Plus
Mortara Surveyor S12/S19
Nellcor (Covidien) N-390, N-395, N-550, N-560, N-595, N-600, N-600x, N-3000, N-3100, N-6000, NPB-290, NPB-295, Symphony N-3000
Nihon Kohden BSM-2300, BSM-2304A, BSM-4100, BSM-4104A, BSM-4114A, BSM-5100
Omron / Colin BP-306, BP-508, BP-808, BP-88, BP-88S, BP-S510, Press-Mate, T105NXM
Oridion Capnostream 20
Philips Prodigy, VS1
Physio-Control Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E
Respironics Alice 5
Welch Allyn 1500, 42NT0-E1 LXi, 45NE0-E1 LX, 53STP, Propaq CS, Spot Vital Signs 42MTB-E1, Spot Vital Signs 42NTB-E1, Spot Vital Signs LXi
Zoll E Series, M Series, R Series

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Nellcor (Covidien) SCP-10, MC-10, OEM10
AMC CB-A400-1011SC
Beta Biomed B505-1011A
Curbell 5579
Datex-Ohmeda 903131
Envitec X-4213
Mindray / Datascope 0012-00-1254
Nihon Kohden NK-SCP-10
Pacific Medical NXNE300
Sage E06-30M
Tenacore TE1723
Unimed U708-69
Welch Allyn 9293-057-51

IPR Medical buys, sells, repairs, and stocks parts for SpO2 adapter cables and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiSmart, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Nellcor SCP-10 Compatible SpO2 Adapter Cable?

The IPR Medical SA-002-24 is a compatible aftermarket SpO2 adapter cable that replaces the Nellcor SCP-10 (not an OEM part). It is built for use with Nellcor OxiSmart SpO2 sensors, linking the sensor to a compatible monitor so pulse oximetry readings reach the bedside display. At 7.9 ft (2.4 m), it gives clinicians room to position the patient and route the cable without pulling on the sensor.


Compatible Monitor Models

This adapter cable is listed as compatible with select Nellcor pulse oximeters, select Mindray and Datascope Passport, Spectrum, Trio, Duo, and Accutorr monitors, select GE Healthcare Dinamap, ProCare, and Carescape monitors, select Datex-Ohmeda, Nihon Kohden, Omron and Colin, and Welch Allyn models, select Physio-Control Lifepak and Zoll units, and select Criticare, Invivo, Mortara, and other monitors. The Datascope Accutorr Plus is listed both as standard and with the Nellcor SpO2 option, so it appears in both rows of the table. See the Compatible Monitor Models table on the Specifications tab for the complete list, and confirm your monitor model and SpO2 option before ordering.


Design and Construction

The cable is a reusable SpO2 adapter cable designed around Nellcor OxiSmart SpO2 technology. It measures 7.9 ft (2.4 m) end to end and ships one per bag. As a reusable accessory, it can be cleaned between patients per facility protocol and the manufacturer’s instructions for your monitor, and kept in service as long as it passes inspection.


When to Replace Your SpO2 Adapter Cable

Replace the adapter cable when you see a cracked or split jacket, exposed conductors, bent or damaged pins at either connector, a loose or wobbly connection at the monitor or sensor, or kinks that do not relax. Intermittent SpO2 readings, frequent sensor-off or no-signal alarms, or readings that drop out when the cable is moved are also common signs of a failing cable. Swapping in a known-good cable is a quick way for biomedical staff to isolate whether the cable, the sensor, or the monitor is at fault.


Cross Reference and Interchange Part Numbers

This compatible cable replaces Nellcor SCP-10 and also cross-references to Nellcor MC-10 and OEM10, Mindray and Datascope 0012-00-1254, Datex-Ohmeda 903131, Nihon Kohden NK-SCP-10, Welch Allyn 9293-057-51, Envitec X-4213, and Curbell 5579. Additional interchange numbers are listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.


Why Source SpO2 Adapter Cables from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps. Our in-house technicians service patient monitoring equipment, so we can help you confirm the right cable for your equipment and keep your fleet in service. Browse more SpO2 cables, sensors, and accessories in our SpO2 category, or call 855-477-8866 for help with ordering, repairs, or parts.

IPR Medical buys, sells, repairs, and stocks parts for SpO2 adapter cables and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nellcor, Philips, or any other manufacturer or supplier named on this page. Nellcor, Philips, OxiSmart, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.