IPR Medical

Recertified

Philips IntelliVue MP30 Patient Monitor | 10.4″ Touchscreen, 12-Lead ECG

$995.00 Original price was: $995.00.$845.95Current price is: $845.95.

The Philips IntelliVue MP30 (M8002A) is a compact, touchscreen-equipped bedside patient monitor designed for intermediate care, ambulatory surgery, post-operative care, special procedures, lower acuity environments, and in-hospital patient transport. Sharing the common IntelliVue platform and user interface with the broader MP-series family, the MP30 delivers powerful clinical measurement capability — including conventional diagnostic 12-lead ECG, multi-lead arrhythmia analysis, capnography, and SpO2 — in a portable package weighing less than 13.2 lbs combined with the Multi-Measurement Server (MMS) and battery. Wired and optional wireless networking connect the MP30 to the Philips IntelliVue Clinical Network and IntelliVue Information Center for enterprise-wide data continuity.

Display 10.4″ color TFT LCD, SVGA resolution; touchscreen standard
Waveforms Up to 4 simultaneously (USA); 12-lead ECG screen available
User Interface Touchscreen (standard); integrated navigation point; optional Remote SpeedPoint
Patient Population Adult, Pediatric, Neonatal
Battery Operation Up to 5 hours with dual lithium-ion batteries (M4605A)
Weight (system) Less than 13.2 lbs (monitor + MMS + battery)
Connectivity Wired LAN standard; optional IEEE 802.11 a/b/g wireless

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue MP30. Contact us at 855-477-8866 or cs@iprmed.com.

SKU: philips-intellivue-mp30-patient-monitor Category: Brand:
Send In Philips IntelliVue MP30 Patient Monitor | 10.4" Touchscreen, 12-Lead ECG for Repair

Philips IntelliVue MP30 — Specifications


Manufacturer Philips Healthcare
Model IntelliVue MP30
Part Number / Catalog Number M8002A
Device Classification Multi-parameter patient monitor
Intended Use Monitoring, recording, and alarming of multiple physiological parameters of adults, pediatrics, and neonates in health care facilities, including transport situations within the hospital setting; for use by trained health care professionals; Rx only
Display 10.4″ (26 cm) color TFT LCD; SVGA resolution; wide viewing angle; touchscreen standard on MP30
Waveforms Up to 4 real-time waves simultaneously (USA); 12-lead ECG screen displays 12 real-time ECG waves with rhythm strip and ST values
Parameters Monitored ECG, arrhythmia, ST segment, QT/QTc, respiration, SpO2, NIBP, invasive pressure, temperature, cardiac output, CO2 (Microstream sidestream and mainstream options via MMS extensions); hemodynamic, ventilation, and oxygenation calculations
SpO2 Technology Philips FAST SpO2 (Fourier Artifact Suppression Technology); additional SpO2 technology options configuration-dependent
NIBP Method Oscillometric via MMS (M3001A); manual, automatic, and sequence modes
ECG Leads 3- to 10-electrode monitoring; 12-lead ECG via EASI method (5 electrodes) or conventional method (10 electrodes); 12 real-time ECG waveforms displayed simultaneously
Arrhythmia Detection Yes — multi-lead arrhythmia detection including ventricular arrhythmias, asystole, bradycardia, and ventricular fibrillation; Philips ST/AR algorithm
ST Segment Analysis Yes — up to 12-lead ST analysis for adult patients; ST elevation and depression; ST alarms; ST Snippets; ST Map; intended for adult patients only
Alarm System Multi-level visual and audible alarms graded by severity (Red/Yellow/Technical INOP); alarm limits permanently visible on main screen; patented automatic alarm limits; latching and non-latching modes; alarm pause (1, 2, 3, 5, or 10 minutes or indefinite); nurse call relay optional
Trend Storage Up to 16 measurement numerics; sampling every 12 seconds, 1 minute, or 5 minutes; stored 4 to 48 hours; MMS stores up to 8 hours of patient trends including demographics
Event Surveillance Neonatal Event Review (NER) — 4-minute episodes sampled 4 times/second; combi-events correlating apnea with bradycardia and/or desaturations; OxyCRG screen for neonatal monitoring
User Interface Touchscreen (standard on MP30); integrated navigation point; PS/2-compatible mouse, trackball, barcode reader; optional Remote SpeedPoint; optional keyboard
Clinical Support Tools Drug calculator (optional); hemodynamic, ventilation, and oxygenation calculations; ProtocolWatch (SSC Sepsis Protocol); ST Map; Horizon trends; 12-lead ECG capture and reporting; OxyCRG neonatal screen
Battery Lithium-ion M4605A (10.8 V, 6000 mAh); up to 5 hours operation (basic monitoring config); one or two batteries supported
Connectivity Wired LAN (standard); optional IEEE 802.11 a/b/g wireless (2.4 GHz / 5 GHz ISM bands); optional Philips Cellular Telemetry System (CTS); MIB/RS-232 interface optional; IntelliVue Information Center integration
Weight (system) Less than 13.2 lbs (monitor + M3001A MMS + battery, without options)
Dimensions (system) Less than 13.6 x 10.8 x 9 in (monitor + MMS + battery)
Patient Categories Adult, Pediatric, Neonatal
Regulatory FDA 510(k) cleared — Class II device, product code MHX (IntelliVue series, cleared March 24, 2006); CE mark (CE0366)
FDA Device Corrections The IntelliVue MP30 has been subject to at least one Class 2 device correction listed in the FDA Medical Device Recalls Database (FDA recall record ID 217166). Facilities should review the Description Tab for additional context and verify current status directly with the FDA.

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue MP30. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips.

Overview

The Philips IntelliVue MP30 (M8002A) is a compact, portable multi-parameter patient monitor built for intermediate care, ambulatory surgery, post-operative care, special procedures, and lower acuity clinical environments, as well as in-hospital patient transport. As a member of the IntelliVue family, the MP30 shares the common IntelliVue user interface and modular technological platform with the broader MP-series — from the MP2 and MP5 through the MP40–MP90 — ensuring that clinical staff already familiar with IntelliVue can work at the MP30 bedside with minimal retraining. Despite its compact footprint, the MP30 delivers robust clinical measurement capability through its modular Multi-Measurement Server (MMS) and optional MMS extensions, supporting parameters including ECG and arrhythmia, SpO2, NIBP, capnography, invasive pressure, temperature, and cardiac output. The MP30 is designed for active monitoring environments where portability matters as much as clinical depth: the system weighs less than 13.2 lbs combined with the MMS and battery, can run on battery power for up to five hours, and connects seamlessly to the Philips IntelliVue Clinical Network for enterprise data continuity.


Display and User Interface

The MP30 features a 10.4-inch (26 cm) color TFT LCD display with SVGA resolution and a wide viewing angle, delivering clear waveform and numeric presentation in a compact package. The display integrates the processing unit and power supply into a single device, reducing cabling and simplifying the overall system architecture. On the MP30, a touchscreen with a resistive touch surface is standard, allowing clinicians to access many monitoring functions through direct on-screen interaction. This distinguishes the MP30 from the MP20, which uses only the integrated navigation point as its primary input device. The MP30 also includes the integrated navigation point as a supplementary input tool — its dial can be rotated for precise on-screen navigation, with tactile resistance at each step. Additional supported input devices include PS/2-compatible mice, trackballs, barcode readers, and an optional Remote SpeedPoint that combines joystick and dial control for full two-dimensional screen navigation. When alpha or numeric entry is required — such as for patient demographics — an on-screen keyboard appears automatically. SmartKeys with intuitive icons provide rapid access to common monitoring tasks directly from the screen without navigating through menu hierarchies.


Clinical Measurements and Module Support

The MP30’s measurement capabilities are delivered primarily through the Multi-Measurement Server (MMS, M3001A), which connects without cables to the rear of the monitor. The MMS provides ECG and arrhythmia analysis, respiration, SpO2, NIBP, and an invasive pressure or temperature port — along with 12-lead ECG capability, multi-lead arrhythmia detection, and 12-lead ST analysis — and stores up to eight hours of patient trend data including demographic information. The IntelliVue X2 (M3002A) multi-measurement module can be used as an alternative to the MMS and additionally provides CO2 measurement. MMS extensions slot directly onto the MMS to expand the measurement menu: the M3015A adds Microstream sidestream CO2 with an optional invasive pressure/temperature port; the M3014A adds mainstream or sidestream CO2 along with additional pressure and temperature channels and optional cardiac output; and the M3012A adds temperature, invasive blood pressure, an additional invasive pressure or temperature port, and optional cardiac output and continuous cardiac output. Arrhythmia analysis uses the Philips ST/AR algorithm to detect ventricular arrhythmias, calculate heart rate, and generate alarms including asystole, bradycardia, and ventricular fibrillation. ST segment analysis supports up to 12 leads in adult patients, with alarm limits, ST Snippets for baseline comparison, and the ST Map application for a graphical visualization of ST changes across the frontal and horizontal planes. QT/QTc interval monitoring provides the measured QT interval and calculated heart-rate-corrected QTc value. SpO2 is delivered via Philips FAST SpO2 technology using Fourier Artifact Suppression Technology for reliable performance even with low perfusion. Optional Bispectral Index (BIS) monitoring is supported via a BIS interface for anesthesia depth assessment in OR environments.


Portability and Power

The MP30 is purpose-built for clinical environments where monitors must move with patients. Combined with the M3001A MMS and one battery, the system weighs less than 13.2 lbs and measures less than 13.6 x 10.8 x 9 inches, making it manageable for transport across departments and floors. The monitor supports one or two M4605A lithium-ion batteries (10.8 V, 6000 mAh each), providing up to five hours of operation on battery power with a basic monitoring configuration. The transition from AC power to battery operation during transport is designed to be seamless — there is no need to disconnect patient cables or adjust measurement or monitor settings when moving between bedside and transport modes. The MMS continues to store patient trends and demographic data during transport, and upon reconnection to a new IntelliVue monitor, automatically uploads stored data without requiring recabling or manual reconfiguration. Mounting solutions designed for the MP30 enable quick disconnect for transport and rapid reconnection to the wall or roll mount upon return to the care area, supporting efficient department workflows in post-operative, intermediate care, and transport settings.


Trending, Event Surveillance, and Clinical Decision Support

The MP30 provides a comprehensive suite of data management and clinical decision support tools. The trend database stores data from up to 16 measurement numerics, with configurable sampling intervals of 12 seconds, one minute, or five minutes, and a storage window of four to 48 hours. Tabular and graphic trend views are available on screen, and an extensive range of patient reports can be printed locally or to centrally connected printers — including vital signs, graphic trends, 12-lead ECG reports, alarm limit reports, event review and episode reports, cardiac output reports, OxyCRG reports, and drug calculator reports. For neonatal patients, the Neonatal Event Review (NER) application stores four-minute episodes sampled four times per second for each event, supporting documentation of rapidly changing neonatal conditions. Combi-events correlate apnea with bradycardia and/or desaturations for integrated neonatal clinical review. The optional OxyCRG screen presents beat-to-beat heart rate, an oxygenation trend, and compressed respiration simultaneously — a neonatal-optimized summary view. The optional drug calculator supports calculation of IV drug dose, rate, amount, volume, concentration, and standardized rate. ProtocolWatch, including the SSC Sepsis Protocol, runs as an integrated clinical protocol application. Horizon trends provide a graphical visualization tool for pattern recognition of patient clinical status. The clinical calculation set supports hemodynamic, oxygenation, and ventilation calculations including cardiac index, stroke volume, systemic vascular resistance, oxygen consumption, minute volume, and more.


Network and EMR Integration

The MP30 connects to the Philips IntelliVue Clinical Network through a standard wired LAN connection, with optional IEEE 802.11 a/b/g wireless networking (2.4 GHz and 5 GHz ISM bands) and optional compatibility with the Philips Cellular Telemetry System (CTS) in WMTS and ISM bands for telemetry infrastructure environments. When networked, the MP30 integrates with the Philips IntelliVue Information Center central monitoring station, enabling simultaneous alarming at the bedside and at the central station, bed-to-bed overview of all monitored patients in a care group, and the Universal ADT feature for shared patient admit/discharge/transfer information that need only be entered once. An optional MIB/RS-232 interface board provides two fully isolated MIB ports for data export to automated anesthesia record keepers, personal computers, or other connected systems. The optional Flexible Nurse Call Relay provides three general alarm relays and one power-fail alarm for integration with external nurse call systems. When a patient is transferred, disconnecting the MMS from the MP30 and reconnecting it to a new IntelliVue monitor carries the patient’s demographic data and stored trends to the new location automatically, requiring no re-entry of patient information.


FDA Device Corrections and Safety Bulletins

The FDA Medical Device Recalls Database lists at least one Class 2 device correction for the Philips IntelliVue MP30 (FDA recall record ID 217166, last updated March 2026). A Class 2 recall classification indicates that the FDA has determined the product may cause temporary or medically reversible adverse health consequences, or that the probability of serious adverse health consequences is remote. Because the full detail of this correction — including the specific software revision or lot scope, the root cause, and the corrective action required — is best reviewed directly from the FDA’s official database, IPR Medical directs facilities to the resources listed below. Additional Class 2 corrections have been issued across the IntelliVue platform’s history affecting multiple monitor models; facilities operating the MP30 should review the FDA database for any entries applicable to their specific device serial number and software revision.

Recommended actions: Facilities operating the Philips IntelliVue MP30 should review FDA recall record ID 217166 and any additional IntelliVue-related recall records in the FDA Medical Device Recalls Database. Confirm the software revision and serial number of the device against the recall scope. Contact Philips Healthcare customer service for guidance on corrective actions applicable to your specific unit configuration.

Because FDA device corrections and safety communications may be updated or expanded after the date of this listing, IPR Medical recommends that facilities also check the FDA’s official resources directly to ensure they have the most current information.

FDA resources for further review:
FDA Medical Device Recalls Database  |
FDA Medical Device Safety


IPR Medical — Buy, Sell, Repair, and Parts

IPR Medical is a secondary-market specialist for Philips IntelliVue patient monitors, including the MP30. IPR purchases pre-owned IntelliVue MP30 units from healthcare facilities, offers MP30 monitors for sale to hospitals, ambulatory surgery centers, post-operative care units, and clinical programs, and performs repair and refurbishment services on MP30 hardware. IPR also stocks compatible MMS modules, MMS extensions, ECG cables, SpO2 sensors, NIBP cuffs, batteries, and mounting accessories for the MP30 platform. Whether a facility needs a cost-effective bedside or transport monitoring solution, a replacement unit for an existing fleet, or parts support for MP30s already in service, IPR Medical’s team can assist with availability verification, compatibility confirmation, and logistics. Contact IPR Medical to discuss your specific MP30 configuration requirements.

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue MP30. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips.

Weight 20 lbs
Dimensions 7 × 17 × 15 in
Product Condition

,

Compatible Parts and Accessories

IPR Medical stocks a range of compatible parts and accessories for the Philips IntelliVue MP30. The sections below cover the most commonly requested components. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.


Multi-Measurement Server (MMS) and X2 Module

M3001A Multi-Measurement Server (MMS) — connects without cables to rear of MP30; provides ECG/arrhythmia, SpO2, NIBP, respiration, invasive pressure or temperature; stores up to 8 hours of trend data
M3002A IntelliVue X2 Multi-Measurement Module — alternative to MMS; adds CO2 measurement; can also be used as a stand-alone monitor

MMS Extensions

M3015A Microstream CO2 MMS Extension — Microstream sidestream capnography; optional invasive blood pressure/temperature port
M3014A Capnography MMS Extension — mainstream or sidestream CO2; second and third invasive blood pressure or temperature ports; optional cardiac output
M3012A Hemodynamic MMS Extension — temperature and invasive blood pressure; additional invasive pressure or temperature port; optional cardiac output and continuous cardiac output

ECG Cables and Leadsets

M1668A 5-lead ECG cable set for use with MMS (trunk cable and 5 leadwires)
M1673A 3-lead ECG cable set for use with MMS (trunk cable and 3 leadwires)
M1644A 10-lead ECG cable set for conventional 12-lead ECG capture with MMS

SpO2 Sensors and Cables

M1191A / M1191AL Philips FAST SpO2 reusable adult finger sensor — standard and long cable variants
M1901B SpO2 extension cable for MMS — connects sensors to MMS SpO2 port
Pediatric / neonatal SpO2 sensors Philips FAST SpO2-compatible sensors for pediatric and neonatal patients — contact IPR to confirm part numbers for your configuration

NIBP Cuffs and Hoses

M1576A Adult reusable NIBP cuff — single-hose; for use with MMS NIBP connector
M1574A NIBP hose — connects reusable or disposable cuff to MMS; standard length
Disposable NIBP cuffs Single-patient-use NIBP cuffs — adult, pediatric, and neonatal sizes available; contact IPR to confirm compatible part numbers

Temperature Probes

21075A Adult/pediatric reusable rectal temperature probe — for use with MMS or hemodynamic extension temperature port
21078A Adult/pediatric reusable skin temperature probe

Power and Battery

M4605A Lithium-ion rechargeable battery — 10.8 V, 6000 mAh; up to 5 hours operation (basic config); one or two batteries supported per monitor
AC power cord Country-specific AC power cord for MP30 main unit — contact IPR to confirm correct cord for your region

Remote Accessories

M8025A Remote Alarm Device — three optical alarm indicators, integrated speaker; On/Standby key for remote monitor control; mounts in conspicuous location
Remote SpeedPoint Optional remote input device — joystick and dial control for full two-dimensional screen navigation; connects to external device interface on monitor

Mounting and Transport Accessories

Roll stand / pole mount Compatible roll stands and pole mounting hardware for portable transport use — contact IPR to confirm compatibility with your MP30 configuration
Wall mount solutions Mounting solutions designed for the IntelliVue MP20/MP30 enabling quick disconnect for transport and rapid reconnection — contact IPR for applicable hardware

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue MP30. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.