GE E-PSM Patient Side Module | CARESCAPE & S/5, 12-Lead, NIBP
The GE E-PSM is a single-width plug-in hemodynamic acquisition module for the CARESCAPE B650, CARESCAPE B850, CARESCAPE B450, and S/5 modular monitor platforms. It combines 12-lead ECG with ST segment analysis, impedance respiration, GE SpO2 with plethysmography, two temperature channels, and DINAMAP-based NIBP in a single module. The E-PSM is the non-IBP variant of the E-PSMP — same ECG, SpO2, NIBP, temperature, and respiration capabilities, without the two invasive pressure channels — making it the right consolidation choice for med-surg, step-down, PACU, and general ward environments where invasive lines are not part of the standard workflow.
| Module Type | Single-width plug-in hemodynamic acquisition module |
| Parameters | ECG, ST, Impedance Respiration, SpO2, NIBP, 2x Temperature |
| ECG Configuration | 3-, 5-, 6-, or 10-leadwire (3-, 7-, 8-, or 12-lead in CARESCAPE) |
| SpO2 Technology | GE SpO2 (Masimo and Nellcor available via separate modules) |
| NIBP Algorithm | GE DINAMAP, oscillometric |
| Compatible Hosts | CARESCAPE B450/B650/B850, S/5 modular (via F5/F7 frame or Module Bus Adapter) |
IPR Medical buys, sells, repairs, and stocks parts for the GE E-PSM Patient Side Module. Contact us at 855-477-8866 or cs@iprmed.com.
GE E-PSM Patient Side Module — Specifications
| Manufacturer | GE Healthcare Finland Oy (GE HealthCare) |
| Model | E-PSM (Patient Side Module) |
| Module Versions (OEM-identified) | E-PSM-00, E-PSM-01 (front panel labeling Rev. 00 and 01) |
| Related Module | E-PSMP (same module with two added invasive pressure channels P1 and P2) |
| Device Classification | Multiparameter hemodynamic plug-in acquisition module for modular patient monitors |
| Module Form Factor | Single-width plug-in module; ECG, SpO2, T1, T2, and dual NIBP connectors on front panel (no P1/P2 connectors) |
| Compatible Host Monitors | CARESCAPE Monitor B450, B650, B850; S/5 FM modular; S/5 with F-CU5P frame |
| Compatible Module Frames | F5 Frame (5 module slots), F7 Frame (7 module slots); also docks directly into S/5 FM. Module Bus Adapter required for F5/F7 cable interface |
| Patient Categories | Adult, pediatric, neonatal (NIBP intended for patients over 11 lbs) |
| ECG Leadwire Configurations | 3, 5, 6, or 10 leadwires (CARESCAPE); 3, 5, or 10 leadwires (S/5) |
| ECG Display Modes | 3-, 7-, 8-, or 12-lead simultaneous display (CARESCAPE); 3-, 7-, or 12-lead (S/5) |
| ST Segment Analysis | Up to 12 leads simultaneously; range -20 to +20 mm; calculated from 8 QRS complexes; trends up to 72 hours |
| 12-Lead Diagnostic Analysis | 12SL and 12RL analysis available with 5-, 6-, or 10-leadwire configurations (host-dependent) |
| Arrhythmia Detection | Lethal arrhythmia analysis standard; full arrhythmia recognition as host monitor software option |
| Impedance Respiration | 4 to 120 breaths/min; accuracy ±5% or ±5 breaths/min; transthoracic impedance 0.2 to 32 Ohm; max base impedance 5 kOhm |
| SpO2 Technology | GE SpO2 (built into module). For Masimo SET or Nellcor OxiMax measurement, separate E-MASIMO or E-NSATX modules are used |
| NIBP Method | Oscillometric (GE DINAMAP); systolic, diastolic, and mean arterial pressure |
| NIBP Measurement Time | Adult typical 23 seconds; infant typical 20 seconds |
| Invasive Pressure Channels | None (use E-PSMP, E-PRESTN, or E-P/E-PP plug-in pressure modules for invasive pressures) |
| Temperature Channels | 2 channels (T1, T2) with differential T2-T1; range 50 to 113 °F; resolution ±0.1 °F |
| Temperature Accuracy | ±0.4 °F (77 to 113 °F); ±0.5 °F (50 to 76.9 °F); GE Healthcare temperature probes or defibrillator-proof YSI 400 series |
| Direct Function Keys | Auto On/Off (NIBP cycle), Start/Cancel (single NIBP) |
| Patient Isolation | 6 kV opto-isolation between patient-applied parts and module bus communication |
| Power | Powered through host monitor module bus (Vmod 13.8–16 V) |
| Software Versions | Module-resident firmware on STP, ECG, and NIBP boards. See the Description Tab for software/host-monitor compatibility detail. |
| Compatible Cables | GE Multi-Link ECG trunk cables and leadwire sets; GE temperature adapter cables; GE TruSignal SpO2 interconnect cables |
IPR Medical buys, sells, repairs, and stocks parts for the GE E-PSM Patient Side Module. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Trademark Notice: GE HealthCare, Masimo, Nellcor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by GE HealthCare, Masimo, or Nellcor.
Overview
The GE E-PSM is the non-IBP variant of GE Healthcare’s Patient Side Module family. In a single module slot it provides 12-lead ECG with ST segment analysis, impedance respiration, GE SpO2 with plethysmography, two temperature channels (T1, T2), and DINAMAP-based NIBP. The E-PSM is mechanically and electrically identical to the E-PSMP with one exception: it does not include the two invasive pressure channels (P1, P2). Facilities deploying the module in care areas where arterial lines, central venous lines, or pulmonary artery catheters are not standard — med-surg, step-down, PACU, recovery, general ward, and many ED bays — typically choose the E-PSM to save the cost and complexity of unused IBP front-end electronics. The module operates as a docking module on the S/5 FM and S/5 F-CU5P frames, and as a plug-in module in the F5 and F7 frames used by the CARESCAPE Monitor B650 and B850 (with the Module Bus Adapter when cabled to a frame).
Display and User Interface
The E-PSM itself does not include a screen. Display, alarms, trends, and configuration are managed by the host monitor — the CARESCAPE B450, B650, or B850 in CARESCAPE deployments, and the S/5 FM in S/5 deployments. The module front panel carries dedicated direct-function keys for Auto On/Off (start/stop NIBP autocycle) and Start/Cancel (single NIBP), allowing the clinician to act on NIBP measurements without navigating host-monitor menus. ECG, SpO2, NIBP, and two temperature connectors are arranged on the front panel for clean cable management at the bedside; the absence of P1 and P2 connectors visually distinguishes the E-PSM from the E-PSMP. The module’s waveforms and numerics inherit the host monitor’s screen layout, color scheme, and care-area configuration, so deployments standardized around CARESCAPE OR, ICU, ED, or PACU profiles continue to look and behave identically when the E-PSM is docked.
Clinical Measurements and Hemodynamic Capability
The ECG section supports 3-, 5-, 6-, or 10-leadwire patient cables, displaying 3-, 7-, 8-, or 12-lead ECG simultaneously on CARESCAPE hosts (3-, 7-, or 12-lead on S/5 hosts). ST segment analysis is calculated continuously from 8-QRS averaged complexes for up to 12 leads, with an ST level range of -20 to +20 mm on CARESCAPE platforms, anterior/inferior/lateral ST limits, and ST trend storage up to 72 hours. QT and QTc values are calculated with 5-, 6-, or 10-leadwire configurations using the 12SL and 12RL analysis algorithms when licensed on the host. Lethal arrhythmia detection is standard; full arrhythmia recognition is enabled by host monitor software licensing. Impedance respiration is measured transthoracically with a range of 4 to 120 breaths/min and accuracy of ±5% or ±5 breaths/min. NIBP uses GE’s DINAMAP oscillometric algorithm and is intended for patients weighing more than 11 lbs (5 kg), with typical adult measurement times around 23 seconds and infant times around 20 seconds. Two temperature channels with differential T2-T1 calculation cover 50 to 113 °F using GE Healthcare temperature probes or defibrillator-proof YSI 400 series probes. For invasive pressure monitoring, the E-PSM is paired with a separate E-P, E-PP, or E-PT plug-in pressure module — or upgraded to the E-PSMP when bedside slot economy is a priority.
SpO2 Technology and Module Family Context
The E-PSM integrates GE SpO2 directly inside the module. Facilities standardized on Masimo SET or Nellcor OxiMax pulse oximetry typically pair the E-PSM with a separate single-parameter SpO2 module — E-MASIMO for Masimo, E-NSATX for Nellcor — installed in an adjacent module slot. This design separates the SpO2 vendor decision from the rest of the hemodynamic stack, which is one reason the E-PSM and E-PSMP remain in service alongside newer parameter modules. Within the broader E-Series catalog, the closely related modules are E-PSMP (E-PSM plus dual IBP), E-PRESTN and E-PRETN (Pressure, Respiration, ECG, Temperature, NIBP — double-width hemodynamic plug-ins), and E-RESTN (no NIBP). Where the E-PSMP is the consolidation choice for slot-constrained deployments that need invasive pressure, the E-PSM is the consolidation choice for the much larger fleet of beds that don’t.
Software Versions and Platform Evolution
The E-PSM is a hardware acquisition module; its parameter measurement firmware lives on three internal boards — the STP (SpO2/Temperature/Pressure) board, the ECG board, and the NIBP board — each carrying its own processor and flash memory. Display software, alarm logic, ST trend storage, arrhythmia analysis, and 12-lead 12SL/12RL diagnostic interpretation all run on the host monitor, not on the module. This means the E-PSM’s clinical capabilities track the host monitor software baseline. On CARESCAPE Monitor B450, B650, and B850 platforms, GE has shipped multiple software versions over the product lifecycle, each adding features such as expanded arrhythmia analysis, additional alarm priorities, ST snapshot management, and care-area specific software packages for OR, PACU, ICU, ED, and NICU. The same physical E-PSM module can move between hosts running different versions, which is one reason GE customers cross-deploy the module across modular fleets. Two front-panel mechanical revisions are catalogued by GE Service Shop — E-PSM Rev. 00 and E-PSM Rev. 01 — with corresponding front panel labeling assemblies. Module assembly SKUs vary by regional catalog and language configuration; IPR Medical can confirm the exact GE part number that matches a given facility’s revision and language requirement.
Service and Maintenance Considerations
The E-PSM is service-friendly compared to the older M-series black modules. The three internal boards (STP, ECG, NIBP) are individually accessible and individually replaceable as field-replaceable units. The NIBP pneumatic stack — pump, manifold, and air filter — is also serviceable, with GE Service Shop catalogues distinct FRUs for the pump unit, manifold unit, module bus connector board, and the front panel unit (which itself is sold in language-specific variants). Common in-service issues seen on the secondary market include NIBP cuff inflation faults (typically pump or manifold), worn or damaged front-panel connectors (especially the ECG D-sub connector), and intermittent SpO2 due to STP board age. NIBP calibration is performed against an external manometer through the host monitor’s service interface. The E-PSM and E-PSMP share most pneumatic and ECG board parts, which simplifies parts pooling for facilities running both variants. IPR Medical performs full functional, calibration, and electrical safety testing as part of refurbishment.
Trending, Event Surveillance, and Clinical Decision Support
Clinical data acquired by the E-PSM — ECG, ST, NIBP, SpO2, temperature, respiration — is sent over the module bus to the host monitor, which is responsible for trend storage, alarm management, event surveillance, and EMR export. ST trends from the E-PSM are stored at one QRST complex every 10 minutes, with manual storage of up to 6 reference complexes, and a maximum 72-hour ST trend window on CARESCAPE hosts. Arrhythmia events captured from the E-PSM ECG channel are time-stamped and stored on the host for review and printing. Because the host monitor manages trending and alarms, the same E-PSM module can move between a PACU-configured CARESCAPE B650 and a step-down-configured B850 and present care-area-appropriate trends without any module-side configuration change. Facilities running the CARESCAPE Central Station can aggregate E-PSM data centrally; facilities using only bedside trending can review trends on the host monitor itself.
Network and EMR Integration
The E-PSM itself is not a networked device — it communicates only with its host monitor over the module bus, with 6 kV opto-isolation between the patient-applied parts and the bus communication. EMR connectivity, MUSE export, and CARESCAPE Central Station communication are all managed by the host monitor’s MC and IX network interfaces. On CARESCAPE Monitor B650 and B850 hosts, the E-PSM’s hemodynamic data flows through the host’s MC Network to the CARESCAPE Central Station and through the IX Network to the MUSE cardiology server (for diagnostic 12-lead ECG transmission), Citrix-published applications, and HL7-based EMR interfaces. This means an E-PSM module deployed in a facility’s existing CARESCAPE infrastructure inherits whatever EMR integration the host monitor is already configured for — no separate networking work is required at the module level.
IPR Medical — Buy, Sell, Repair, and Parts
IPR Medical buys, sells, and repairs the GE E-PSM and E-PSMP Patient Side Modules and stocks the related field-replaceable units, ECG cables and leadwires, NIBP cuffs and hoses, and temperature probes and adapters. We can quote single-module replacements, fleet refurbishments, and depot-level repair for facilities standardizing on the CARESCAPE B450, B650, or B850 platform. Because module assembly SKUs vary by language and regional catalog, we strongly recommend providing the engraved E-PSM-00 or E-PSM-01 designator and the front-panel language when requesting a quote so we can match the correct revision. Facilities upgrading from E-PSM to E-PSMP for a subset of beds — typically OR or ICU — can usually reuse existing ECG, SpO2, NIBP, and temperature accessories without change.
IPR Medical buys, sells, repairs, and stocks parts for the GE E-PSM Patient Side Module. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Trademark Notice: GE HealthCare, Masimo, Nellcor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by GE HealthCare, Masimo, or Nellcor.
| Weight | 20 lbs |
|---|---|
| Dimensions | 7 × 17 × 15 in |
| Product Condition |
Compatible Parts and Accessories
IPR Medical stocks a range of compatible parts and accessories for the GE E-PSM Patient Side Module. The sections below cover the most commonly requested components. Contact us at 855-477-8866 or cs@iprmed.com to confirm the exact OEM part number that matches your revision and language configuration.
Module Field-Replaceable Units (FRU)
| STP-CO Board, E-PSM(P) | Internal PCB carrying the SpO2 and temperature measurement front-end. Cataloged as a service-replaceable unit by GE Service Shop. Contact IPR Medical for the exact OEM part number matching your E-PSM revision. |
| ECG Board, E-PSM(P) | Internal PCB carrying the ECG and impedance respiration front-end. Replaced when ECG channels become noisy, drifting, or unresponsive. Contact IPR Medical for the exact OEM part number. |
| NIBP Board, E-PSM(P) | Internal PCB driving the NIBP pump and pressure sensing. Listed in the GE Service Shop catalog as a serviceable FRU. |
| Module Flex Board Unit, E-PSM(P) | Flex interconnect carrying signals between the module’s main boards. Cataloged in the GE technical manual as an FRU. |
| NIBP Manifold Unit | E-PSM(P)-01 NIBP Manifold Unit, FRU (GE Service Shop reference M1221539). Pneumatic distribution block for the NIBP pump. |
| NIBP Pump | E-PSM(P) NIBP Pump (GE Service Shop reference M1221540). Inflates the cuff to set pressure (typically up to 260 mmHg). Common wear item on heavily-used modules. |
| NIBP Air Filter | Intake filter for the NIBP pump; replaced as part of preventive maintenance per the E-PSM technical manual. |
| Module Bus Connector Board | E-PSM(P)-01 Module Bus Connector Board, FRU (GE Service Shop reference M1221542). Carries the module-to-frame backplane connection. |
| Front Panel Unit (Language-Specific) | E-PSM front panel units are stocked by GE Service Shop in language-specific sets (EN/NL/IT, FI/DA/NO/PL/CS/HU/SV, and others). Contact IPR Medical for the language-specific OEM part number matching your fleet. |
| E-PSM(P) Plastic Parts FRU | Replacement plastic housing parts cataloged in the GE technical manual for the E-PSM(P) family. |
| E-PSM(P) Module Frame | Module frame/chassis assembly (GE Service Shop reference M1221537). Required when the module housing itself is damaged. |
Compatible Module Frames and Adapters
| F5 Module Frame | 5-slot E-Series module frame for CARESCAPE Monitor B650 and B850. Supports all E-Series acquisition modules. |
| F7 Module Frame | 7-slot E-Series module frame for CARESCAPE Monitor B650 and B850. Same module compatibility as F5. |
| Module Bus Adapter for E-PSM | Required cable adapter when interfacing the E-PSM to an F5 or F7 frame remotely. Contact IPR Medical for the specific OEM part number matching your installation. |
| F-CU5P Frame | S/5 modular frame supporting plug-in PSM/PSMP modules. |
ECG Cables and Leadsets
| 3-Lead ECG Trunk Cable, AHA | GE Multi-Link 3-leadwire ECG trunk cable. Multiple lengths available; contact IPR Medical for the OEM part number matching your length and termination. |
| 5-Lead ECG Trunk Cable, AHA | GE Multi-Link 5-leadwire ECG trunk cable, 8 ft and 12 ft variants commonly stocked. |
| 6-Lead ECG Trunk Cable | GE Multi-Link 6-leadwire ECG trunk cable for 12RL analysis configurations. |
| 10-Lead ECG Trunk Cable | GE Multi-Link 10-leadwire ECG trunk cable for full 12-lead 12SL diagnostic analysis. |
| ECG Leadwire Sets (Snap and Grabber) | 3-, 5-, 6-, and 10-leadwire sets in snap or grabber/pinch terminations, AHA and IEC color codes available. |
SpO2 Sensors and Cables (GE SpO2)
| GE TruSignal SpO2 Interconnect Cable | Connects GE TruSignal sensors to the E-PSM front-panel SpO2 connector. Multiple lengths available. |
| GE TruSignal Reusable Finger Sensor (Adult) | Reusable adult clip-style SpO2 sensor for GE-branded SpO2 acquisition. |
| GE TruSignal Disposable SpO2 Sensors | Adhesive disposable sensors in adult, pediatric, infant, and neonatal sizes. |
NIBP Cuffs and Hoses
| GE DURA-CUF Reusable NIBP Cuffs | Reusable cuffs in pediatric, small adult, adult, large adult, and thigh sizes; double-tube and single-tube variants. Contact IPR Medical for the size and configuration matching your population. |
| GE Soft-Cuf Disposable NIBP Cuffs | Single-patient-use cuffs in neonatal through large adult sizes. |
| NIBP Double-Tube Hose, Adult/Pediatric | GE Marquette double-tube NIBP hose with metal or plastic connector (e.g., 2020980-001, 9461-217). Contact IPR Medical to match the connector style on your cuff inventory. |
| NIBP Hose with Dinaclick Dual Connector | GE NIBP double-tube hose with Dinaclick connector (e.g., 2058203-002, 2058203-003). |
| Neonatal Dual NIBP Hose | GE neonatal dual NIBP hose (e.g., 2017009-003). |
Temperature Probes and Adapter Cables
| YSI 400 Series Temperature Adapter Cable | GE Marquette YSI 400 dual female mono plug to rectangular 10-pin adapter, 1 ft. Required for defibrillator-proof YSI 400 probes. |
| YSI 700 Series Temperature Adapter Cable | GE Marquette YSI 700 dual female mono plug to rectangular 10-pin adapter, 1 ft. |
| Reusable Adult Skin Temperature Sensor | GE Marquette adult reusable skin temperature sensor (9445-008), male mono plug, 9 ft. |
| Reusable Adult Rectal Temperature Probe | GE Marquette adult reusable rectal temperature probe (9445-004), male mono plug, 9 ft. |
| Disposable Temperature Probes | Single-patient-use skin, esophageal/rectal, and foley-style temperature probes — contact IPR Medical for size and YSI series. |
IPR Medical buys, sells, repairs, and stocks parts for the GE E-PSM Patient Side Module. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.
Reviews
There are no reviews yet.