    Philips IntelliVue M3001A Multi-Measurement Module | Option A01C12, 12-Lead ECG & FAST SpO2

    Original price was: $1,095.00.Current price is: $995.00.

    The Philips IntelliVue M3001A (Option A01C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module with Philips FAST SpO2. Building on the A01 standard package — ECG, arrhythmia, ST, respiration, FAST SpO2, and oscillometric NBP — the C12 option adds conventional 12-lead ECG capture capability and EASI-derived 12-lead ECG using only 5 electrodes. The A01C12 is the correct choice for facilities that require diagnostic-quality 12-lead ECG at the bedside alongside continuous monitoring but do not need invasive pressure or temperature measurement in the MMS module itself. It is widely deployed in step-down units, telemetry floors, cardiac monitoring environments, and pre-/post-procedure areas where 12-lead ECG documentation is a standard clinical workflow. As with all M3001A variants, patient demographics, trend data, and measurement settings are stored within the module and travel with the patient between IntelliVue host monitors.

    Part Number / Option
    M3001A, Option A01C12

    Parameters Monitored
    ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Philips FAST SpO2, NBP (oscillometric)

    SpO2 Technology
    Philips FAST SpO2 — compatible with Nellcor OxiMax sensors

    12-Lead ECG
    Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supported

    Invasive Pressure / Temperature
    Not included in Option A01C12 — available with Option A01C18

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -9%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A02C12, 12-Lead ECG & Nellcor OxiMax SpO2

    Original price was: $1,095.00.Current price is: $995.00.

    The Philips IntelliVue M3001A (Option A02C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Nellcor OxiMax sensors. Building on the A02 standard package — ECG, arrhythmia, ST, respiration, Nellcor OxiMax-compatible SpO2, and oscillometric NBP — the C12 option adds conventional 12-lead ECG capture and EASI-derived 12-lead ECG using only 5 electrodes. The A02C12 is clinically identical to the A01C12 in every respect except that the SpO2 interface uses a dedicated OxiMax-compatible circuit rather than Philips FAST SpO2, and OxiMax sensors connect through the M1943NL adapter cable rather than directly to the module’s SpO2 port. It is the correct choice for facilities that require documented, diagnostic-quality 12-lead ECG recordings alongside continuous monitoring and are standardized on Nellcor OxiMax sensors, but do not need invasive pressure or temperature within the MMS module itself.

    Part Number / Option
    M3001A, Option A02C12

    Parameters Monitored
    ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric)

    SpO2 Technology
    Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connection

    12-Lead ECG
    Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supported

    Invasive Pressure / Temperature
    Not included in Option A02C12 — available with Option A02C18

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -9%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A02C18, 12-Lead ECG, Nellcor OxiMax SpO2, IBP & Temp

    Original price was: $1,095.00.Current price is: $995.00.

    The Philips IntelliVue M3001A (Option A02C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Nellcor OxiMax sensors. The C18 option combines both extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG using 5 electrodes, QT/QTc monitoring, respiration, Nellcor OxiMax-compatible SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration with OxiMax sensor compatibility. The A02C18 is the direct Nellcor OxiMax equivalent of the A01C18: clinically identical in every measurement capability, with OxiMax sensors connecting through the M1943NL adapter cable. As with all M3001A C-option configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.

    Part Number / Option
    M3001A, Option A02C18

    Parameters Monitored
    ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)

    SpO2 Technology
    Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connection

    12-Lead ECG
    Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supported

    IBP / Temp Port
    One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this port

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -23%
    RecertifiedQuick View

    Philips IntelliVue M3012A Hemodynamic Extension | Option C00, Dual Pressure & Dual Temperature

    Original price was: $1,295.00.Current price is: $995.00.

    The Philips IntelliVue M3012A (Option C00) is the base configuration of the IntelliVue Hemodynamic Measurement Server Extension. It attaches directly to the Philips M3001A Multi-Measurement Module to add two independent invasive pressure channels, two independent temperature channels, and one combined pressure/temperature connector — enabling simultaneous hemodynamic pressure and temperature monitoring that the M3001A’s single shared C06 or C18 connector cannot provide on its own. The M3012A C00 is the standard hemodynamic expansion unit for ICU, cardiovascular step-down, and critical care transport environments where multiple pressure lines, bilateral temperature monitoring, or both are required alongside the M3001A’s core vital signs parameter set, but cardiac output measurement is not part of the clinical protocol.

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3012A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -8%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A03, Masimo SET SpO2

    Original price was: $1,195.00.Current price is: $1,095.00.

    The Philips IntelliVue M3001A (Option A03) is the Masimo SET-equipped configuration of the IntelliVue Multi-Measurement Module, designed for acute care facilities standardized on the Masimo LNCS sensor platform. Sharing the same ECG, arrhythmia, ST, respiration, and oscillometric NBP capability as all M3001A variants, the A03 option integrates a dedicated Masimo SET SpO2 interface that communicates natively with Masimo LNCS sensors via the LNC MP-10 dual-key patient cable. The module docks directly to the rear of any compatible IntelliVue host monitor — or connects remotely via MSL cable — and transmits all measurement data to the host display without requiring cable changes or parameter re-setup between monitoring locations. Patient demographics, trend data, and measurement settings are stored within the module itself and travel with the patient during unit transfers.

    Part Number / Option
    M3001A, Option A03

    Parameters Monitored
    ECG (3/5-lead), Arrhythmia, ST, Respiration, Masimo SET SpO2, NBP (oscillometric)

    SpO2 Technology
    Masimo SET — for use with Masimo LNCS sensors via LNC MP-10 patient cable

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    Optional Extensions
    M3015A (sidestream CO2), M3016A (mainstream CO2), M3012A (additional press/temp/CO2)

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -15%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A04C06, Nellcor OxiMax SpO2, IBP & Temp

    Original price was: $1,295.00.Current price is: $1,095.00.

    The Philips IntelliVue M3001A (Option A04C06) is the extended-measurement, newer-hardware-generation configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Nellcor OxiMax sensors. Building on the A04 standard package — ECG, arrhythmia, ST, respiration, Nellcor OxiMax-compatible SpO2, and oscillometric NBP — the C06 option adds a combined invasive pressure and temperature connector, enabling the module to support either invasive blood pressure monitoring or temperature measurement alongside the full core parameter set. The A04C06 is the Hardware Revision C equivalent of the A02C06: clinically identical in measurement capability and OxiMax sensor compatibility, but built on the newer internal platform identified by serial number prefixes DE610, DE632, DE717, and DE907. As with all M3001A C06 configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously. Patient demographics, trend data, and measurement settings are stored in the module itself and travel with the patient between IntelliVue host monitors.

    Part Number / Option
    M3001A, Option A04C06

    Parameters Monitored
    ECG (3/5-lead), Arrhythmia, ST, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)

    SpO2 Technology
    Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connection

    Hardware Generation
    Revision C — serial number prefixes DE610, DE632, DE717, DE907; newer platform vs. A02C06

    IBP / Temp Port
    One combined connector — supports invasive pressure transducer OR temperature probe; pressure and temperature cannot be used simultaneously on this port

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips CL Wireless ECG / IUP Transducer (866077)

    $1,195.00

    The Philips Avalon CL Wireless ECG/IUP Transducer (866077) is a cableless, battery-powered transducer that captures maternal ECG, fetal ECG (DECG), and intrauterine pressure (IUP) on a single device — giving labor and delivery teams three internal and maternal measurements without tethering the patient to the monitor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same measurement performance as wired Smart Transducers while letting mothers walk, shower, or reposition during labor with an operating range of up to 100 m (300 ft) line of sight.

    The 866077 is watertight for underwater monitoring, weighs only 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic assignment and battery recharging — no patient cables, no separate charger. IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.

  • Recertified
    Quick View

    Philips IntelliVue X2 Multi-Measurement Module

    $1,295.00

    The Philips IntelliVue X2 (M3002A) is a combined Multi-Measurement Module and portable transport monitor designed for use across the hospital continuum — from the ICU and OR to intra-hospital transport and intermediate care. In standalone mode it operates on a rechargeable battery and monitors ECG, arrhythmia, ST, respiration, SpO2, NBP, and optional invasive pressure, temperature, and CO2; when docked to a host IntelliVue monitor it seamlessly hands off all measurements, trends, and patient data as an MMS. The X2’s 3.5-inch touchscreen and configurable SmartKeys give clinicians immediate access to parameters and alarm controls without interrupting patient monitoring.

    Display
    3.5-inch TFT LCD touchscreen, QVGA

    Parameters Monitored
    ECG (3/5/6/10-lead), Arrhythmia, ST, QT/QTc, Respiration, SpO2, NBP, Temp (opt.), IBP (opt.), CO2 (opt.)

    Patient Population
    Adult, Pediatric, Neonatal

    Battery / Portability
    Rechargeable M4607A battery; up to ~3 hrs standalone; up to ~6 hrs with Battery Extension

    Device Weight
    1.98–2.64 lbs (depending on options)

    Connectivity
    Wired LAN, built-in WLAN, Short Range Radio (SRR), MSL connector

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90 (MMS mode)

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue X2. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips M2734A / M2734B Smart Toco MP Transducer | Avalon

    $1,395.00

    The Philips M2734A and M2734B are wired Smart Toco MP transducers used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50). They combine two parameters in a single sensor — external uterine activity (Toco) and maternal pulse (MP) — and enable the Avalon platform’s Smart Pulse automated coincidence detection, which cross-checks the maternal pulse against the fetal heart rate to confirm the host monitor is not inadvertently tracking maternal heart rate as fetal. The M2734B is the successor revision to the M2734A and is functionally interchangeable on the Avalon Toco socket; both are auto-identifying via the Smart-interface (pink) connector and carry internal calibration data storage.

    Device Type
    Wired dual-parameter Smart Toco MP transducer (uterine activity + maternal pulse)

    Models
    M2734A (original Smart Toco MP) and M2734B (successor revision); both share the same role and Avalon socket

    Compatible Monitors
    Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) at supported software revisions

    Connector
    Wired Smart-interface (pink) connector to the dedicated Toco socket on the Avalon host monitor

    Key Features
    Dual-parameter Toco + maternal pulse, Smart Pulse coincidence detection, waterproof housing for shower/bath use, latex-free, auto-identification, internal calibration data storage

    Patient Population
    Antepartum testing and labor and delivery

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon fetal monitor family, including the M2734A and M2734B Smart Toco MP transducers. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips Compatible Wireless Toco Transducer for Philips Avalon | M2725A

    $1,395.00

    This is an aftermarket-compatible cordless Toco transducer designed to function as a direct replacement for the M2725A wireless Toco fetal transducer used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50) when paired with the Avalon CTS cordless transducer base station (M2720A). It uses a strain-gauge pressure sensor to detect uterine activity by evaluating the hardness of the maternal abdomen during labor, transmitting the signal wirelessly to the CTS base so the patient retains freedom of movement during antepartum testing and labor and delivery. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.

    Device Type
    Aftermarket-compatible cordless (wireless) external Toco transducer for fetal/maternal monitoring

    Replaces / Cross Reference
    M2725A cordless Toco transducer (also referenced as part 862488)

    Compatible Monitors
    Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) — used together with the Avalon CTS base station (M2720A)

    Patient Population
    Antepartum testing and labor and delivery; ambulatory patients within the CTS base station’s coverage area

    Key Features
    Cordless operation, lightweight handheld form factor, waterproof housing for shower/bath use during labor, on-board status indicators

    Mounting
    Snap-clip belt fixing onto compatible reusable or waterproof fetal monitoring belts

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Cordless Transducer System (CTS), including aftermarket-compatible wireless Toco transducers for the M2725A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -13%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A03C06, Masimo SET SpO2, IBP & Temp

    Original price was: $1,595.00.Current price is: $1,395.00.

    The Philips IntelliVue M3001A (Option A03C06) is the extended-measurement configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. Building on the A03 standard package — ECG, arrhythmia, ST, respiration, Masimo SET SpO2, and oscillometric NBP — the C06 option adds a combined invasive pressure and temperature connector, enabling the module to support either invasive blood pressure monitoring or temperature measurement in addition to the full core parameter set. The A03C06 is the Masimo SET equivalent of the A01C06 and A02C06, delivering an identical clinical measurement footprint while using a dedicated Masimo SET SpO2 interface and requiring the Masimo LNC MP-10 dual-key patient cable for sensor connection. This configuration is widely deployed in ICU, cardiovascular step-down, post-anesthesia care, and critical care transport environments where arterial line monitoring or core temperature tracking is standard practice alongside a Masimo LNCS sensor fleet. As with all M3001A variants, patient demographics, trend data, and measurement settings are stored in the module itself and travel with the patient between IntelliVue host monitors.

    Part Number / Option
    M3001A, Option A03C06

    Parameters Monitored
    ECG (3/5-lead), Arrhythmia, ST, Respiration, Masimo SET SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)

    SpO2 Technology
    Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection

    IBP / Temp Port
    One combined connector — supports invasive pressure transducer OR temperature probe; pressure and temperature cannot be used simultaneously on this port

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -13%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A03C12, 12-Lead ECG & Masimo SET SpO2

    Original price was: $1,595.00.Current price is: $1,395.00.

    The Philips IntelliVue M3001A (Option A03C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. Building on the A03 standard package — ECG, arrhythmia, ST, respiration, Masimo SET SpO2, and oscillometric NBP — the C12 option adds conventional 12-lead ECG capture and EASI-derived 12-lead ECG using only 5 electrodes. The A03C12 is the Masimo SET equivalent of the A01C12 and A02C12: clinically identical in 12-lead ECG capability and overall parameter set, with the SpO2 interface built around a dedicated Masimo SET circuit, and Masimo LNCS sensors connecting via the Masimo LNC MP-10 dual-key patient cable (part 2281). It is the correct choice for facilities that require documented, diagnostic-quality 12-lead ECG recordings alongside continuous monitoring and are standardized on Masimo LNCS sensors, but do not need invasive pressure or temperature within the MMS module itself.

    Part Number / Option
    M3001A, Option A03C12

    Parameters Monitored
    ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Masimo SET SpO2, NBP (oscillometric)

    SpO2 Technology
    Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection

    12-Lead ECG
    Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supported

    Invasive Pressure / Temperature
    Not included in Option A03C12 — available with Option A03C18

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.