IPR Medical

  • -13%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A03C06, Masimo SET SpO2, IBP & Temp

    Original price was: $1,595.00.Current price is: $1,395.00.

    The Philips IntelliVue M3001A (Option A03C06) is the extended-measurement configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. Building on the A03 standard package — ECG, arrhythmia, ST, respiration, Masimo SET SpO2, and oscillometric NBP — the C06 option adds a combined invasive pressure and temperature connector, enabling the module to support either invasive blood pressure monitoring or temperature measurement in addition to the full core parameter set. The A03C06 is the Masimo SET equivalent of the A01C06 and A02C06, delivering an identical clinical measurement footprint while using a dedicated Masimo SET SpO2 interface and requiring the Masimo LNC MP-10 dual-key patient cable for sensor connection. This configuration is widely deployed in ICU, cardiovascular step-down, post-anesthesia care, and critical care transport environments where arterial line monitoring or core temperature tracking is standard practice alongside a Masimo LNCS sensor fleet. As with all M3001A variants, patient demographics, trend data, and measurement settings are stored in the module itself and travel with the patient between IntelliVue host monitors.

    Part Number / Option
    M3001A, Option A03C06

    Parameters Monitored
    ECG (3/5-lead), Arrhythmia, ST, Respiration, Masimo SET SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)

    SpO2 Technology
    Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection

    IBP / Temp Port
    One combined connector — supports invasive pressure transducer OR temperature probe; pressure and temperature cannot be used simultaneously on this port

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -9%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A02C06, Nellcor OxiMax SpO2, IBP & Temp

    Original price was: $1,095.00.Current price is: $995.00.

    The Philips IntelliVue M3001A (Option A02C06) is the extended-measurement configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Nellcor OxiMax sensors. Building on the A02 standard package — ECG, arrhythmia, ST, respiration, Nellcor OxiMax-compatible SpO2, and oscillometric NBP — the C06 option adds a combined invasive pressure and temperature connector, enabling the module to support either invasive blood pressure monitoring or temperature measurement in addition to the full core parameter set. The A02C06 is the OxiMax-sensor equivalent of the A01C06, delivering an identical clinical measurement footprint while using a dedicated OxiMax-compatible SpO2 interface in place of the Philips FAST SpO2 circuit. This configuration is widely deployed in ICU, cardiovascular step-down, post-anesthesia care, and critical care transport environments where arterial line monitoring or core temperature tracking is routinely required alongside a Nellcor OxiMax sensor fleet. As with all M3001A variants, patient demographics, trend data, and measurement settings are stored in the module itself and travel with the patient between IntelliVue host monitors.

    Part Number / Option
    M3001A, Option A02C06

    Parameters Monitored
    ECG (3/5-lead), Arrhythmia, ST, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)

    SpO2 Technology
    Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connection

    IBP / Temp Port
    One combined connector — supports invasive pressure transducer OR temperature probe; pressure and temperature cannot be used simultaneously on this port

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -9%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A01C06, FAST SpO2, IBP & Temp

    Original price was: $1,095.00.Current price is: $995.00.

    The Philips IntelliVue M3001A (Option A01C06) is the extended-measurement configuration of the IntelliVue Multi-Measurement Module with Philips FAST SpO2. Building on the A01 standard package — ECG, arrhythmia, ST, respiration, FAST SpO2, and oscillometric NBP — the C06 option adds a combined invasive pressure and temperature connector, enabling the module to support either invasive blood pressure monitoring or temperature measurement in addition to the full core parameter set. This makes the A01C06 the most clinically complete single-MMS configuration available without adding 12-lead ECG, and the module most commonly deployed in ICU, step-down, and critical care transport environments where arterial line monitoring or core temperature tracking is routinely required. As with all M3001A variants, patient demographics, trend data, and measurement settings are stored in the module itself and travel with the patient between IntelliVue host monitors.

    Part Number / Option
    M3001A, Option A01C06

    Parameters Monitored
    ECG (3/5-lead), Arrhythmia, ST, Respiration, Philips FAST SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)

    SpO2 Technology
    Philips FAST SpO2 — compatible with Nellcor OxiMax sensors

    IBP / Temp Port
    One combined connector — supports invasive pressure transducer OR temperature probe; pressure and temperature cannot be used simultaneously on this port

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -9%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A04, Nellcor OxiMax SpO2

    Original price was: $1,095.00.Current price is: $995.00.

    The Philips IntelliVue M3001A (Option A04) is the newer-hardware-generation Nellcor OxiMax-compatible configuration of the IntelliVue Multi-Measurement Module. Like the A02, the A04 uses a dedicated Nellcor OxiMax-compatible SpO2 interface and delivers the same core clinical measurement set — ECG, arrhythmia, ST, respiration, OxiMax SpO2, and oscillometric NBP — to any compatible IntelliVue host monitor. The defining distinction from the A02 is internal: the A04 runs on the newer hardware revision C platform, identified by serial number prefixes DE610, DE632, DE717, and DE907, which integrates the DC/DC power circuit onto the main board rather than as a separate component. This hardware generation supports a wider range of IntelliVue software revisions and uses a distinct parameter board assembly. The A04 is the correct Nellcor OxiMax module choice for facilities sourcing units or parts for newer-generation M3001A hardware, or for host monitors requiring hardware revision C compatibility.

    Part Number / Option
    M3001A, Option A04

    Parameters Monitored
    ECG (3/5-lead), Arrhythmia, ST, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric)

    SpO2 Technology
    Nellcor OxiMax-compatible — for use with Nellcor OxiMax sensor line via M1943NL adapter cable

    Hardware Generation
    Revision C — serial number prefixes DE610, DE632, DE717, DE907; newer platform vs. A02

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -8%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A03, Masimo SET SpO2

    Original price was: $1,195.00.Current price is: $1,095.00.

    The Philips IntelliVue M3001A (Option A03) is the Masimo SET-equipped configuration of the IntelliVue Multi-Measurement Module, designed for acute care facilities standardized on the Masimo LNCS sensor platform. Sharing the same ECG, arrhythmia, ST, respiration, and oscillometric NBP capability as all M3001A variants, the A03 option integrates a dedicated Masimo SET SpO2 interface that communicates natively with Masimo LNCS sensors via the LNC MP-10 dual-key patient cable. The module docks directly to the rear of any compatible IntelliVue host monitor — or connects remotely via MSL cable — and transmits all measurement data to the host display without requiring cable changes or parameter re-setup between monitoring locations. Patient demographics, trend data, and measurement settings are stored within the module itself and travel with the patient during unit transfers.

    Part Number / Option
    M3001A, Option A03

    Parameters Monitored
    ECG (3/5-lead), Arrhythmia, ST, Respiration, Masimo SET SpO2, NBP (oscillometric)

    SpO2 Technology
    Masimo SET — for use with Masimo LNCS sensors via LNC MP-10 patient cable

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    Optional Extensions
    M3015A (sidestream CO2), M3016A (mainstream CO2), M3012A (additional press/temp/CO2)

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -9%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A02, Nellcor OxiMax SpO2

    Original price was: $1,095.00.Current price is: $995.00.

    The Philips IntelliVue M3001A (Option A02) is the Nellcor OxiMax-compatible configuration of the IntelliVue Multi-Measurement Module for the IntelliVue bedside patient monitoring platform. Functionally identical to the standard M3001A in ECG, arrhythmia, ST, respiration, and oscillometric NBP capability, the A02 option is specifically engineered for facilities standardized on Nellcor OxiMax sensors — using a dedicated OxiMax-compatible SpO2 interface rather than the Philips FAST SpO2 circuit found in Option A01. The module plugs directly into the rear of any compatible IntelliVue host monitor — or connects via MSL cable — and transmits all measurement data to the host display without requiring cable changes or parameter re-setup between units. Patient demographics, trend data, and measurement settings are stored within the module itself, so the patient record travels with the MMS when the patient moves between units or monitors.

    Part Number / Option
    M3001A, Option A02

    Parameters Monitored
    ECG (3/5-lead), Arrhythmia, ST, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric)

    SpO2 Technology
    Nellcor OxiMax-compatible — for use with Nellcor OxiMax sensor line

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    Optional Extensions
    M3015A (sidestream CO2), M3016A (mainstream CO2), M3012A (additional press/temp/CO2)

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

     

  • -9%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A01, FAST SpO2

    Original price was: $1,095.00.Current price is: $995.00.

    The Philips IntelliVue M3001A (Option A01) is the standard-configuration Multi-Measurement Module for the IntelliVue bedside patient monitoring platform. Designed to plug directly into the rear of IntelliVue MP-series and MX-series host monitors — or connect via MSL cable — the M3001A acquires and transmits ECG, arrhythmia, ST segment, respiration, Philips FAST SpO2, and oscillometric NBP measurements to the host display without requiring cable changes or parameter re-setup. Because patient demographics, trend data, and measurement settings are stored in the module itself, the M3001A travels with the patient: disconnect it at one IntelliVue monitor and reconnect it at another, and the patient record follows seamlessly. The A01 option designates Philips FAST SpO2 pulse oximetry technology and is compatible with the full Nellcor OxiMax sensor line.

    Part Number / Option
    M3001A, Option A01

    Parameters Monitored
    ECG (3/5-lead), Arrhythmia, ST, Respiration, Philips FAST SpO2, NBP (oscillometric)

    SpO2 Technology
    Philips FAST SpO2 — compatible with Nellcor OxiMax sensors

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    Optional Extensions
    M3015A (sidestream CO2), M3016A (mainstream CO2), M3012A (additional press/temp/CO2)

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -15%
    RecertifiedQuick View

    Philips IntelliVue MP30 Patient Monitor | 10.4″ Touchscreen, 12-Lead ECG

    Original price was: $995.00.Current price is: $845.95.

    The Philips IntelliVue MP30 (M8002A) is a compact, touchscreen-equipped bedside patient monitor designed for intermediate care, ambulatory surgery, post-operative care, special procedures, lower acuity environments, and in-hospital patient transport. Sharing the common IntelliVue platform and user interface with the broader MP-series family, the MP30 delivers powerful clinical measurement capability — including conventional diagnostic 12-lead ECG, multi-lead arrhythmia analysis, capnography, and SpO2 — in a portable package weighing less than 13.2 lbs combined with the Multi-Measurement Server (MMS) and battery. Wired and optional wireless networking connect the MP30 to the Philips IntelliVue Clinical Network and IntelliVue Information Center for enterprise-wide data continuity.

    Display
    10.4″ color TFT LCD, SVGA resolution; touchscreen standard

    Waveforms
    Up to 4 simultaneously (USA); 12-lead ECG screen available

    User Interface
    Touchscreen (standard); integrated navigation point; optional Remote SpeedPoint

    Patient Population
    Adult, Pediatric, Neonatal

    Battery Operation
    Up to 5 hours with dual lithium-ion batteries (M4605A)

    Weight (system)
    Less than 13.2 lbs (monitor + MMS + battery)

    Connectivity
    Wired LAN standard; optional IEEE 802.11 a/b/g wireless

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue MP30. Contact us at 855-477-8866 or cs@iprmed.com.

  • -23%
    Recertified
    Quick View

    Philips IntelliVue MP70 Patient Monitor | Touchscreen, 12-Lead ECG

    Original price was: $1,295.00.Current price is: $995.00.

    The Philips IntelliVue MP70 (M8007A) is a high-performance bedside patient monitor designed for adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; and cardiac care environments. Integrating a 15-inch color XGA touchscreen display with an extensive clinical measurement menu — including conventional diagnostic 12-lead ECG, multi-lead arrhythmia analysis, and Event Surveillance — the MP70 operates on Philips’ networked IntelliVue platform, enabling seamless data flow across the hospital enterprise. Its modular architecture supports the Multi-Measurement Server (MMS), MMS extensions, and the Flexible Module Server (FMS), making it a configurable solution for evolving departmental needs.

    Display
    15″ color XGA LCD touchscreen

    Waveforms
    Up to 8 simultaneously; 12-lead ECG screen available

    User Interface
    Touchscreen (standard); optional SpeedPoint and Remote SpeedPoint

    Patient Population
    Adult, Pediatric, Neonatal

    SpO2 Technology
    Philips FAST SpO2, Masimo SET, Nellcor OxiMax

    Screen Configurations
    10 pre-set configurations; fully customizable

    Module Support
    MMS, MMS extensions, FMS (8 slots); 2 integrated plug-in slots (modules sold separately)

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue MP70. Contact us at 855-477-8866 or cs@iprmed.com.

  • Recertified
    Quick View

    Philips IntelliVue X2 Multi-Measurement Module

    $1,295.00

    The Philips IntelliVue X2 (M3002A) is a combined Multi-Measurement Module and portable transport monitor designed for use across the hospital continuum — from the ICU and OR to intra-hospital transport and intermediate care. In standalone mode it operates on a rechargeable battery and monitors ECG, arrhythmia, ST, respiration, SpO2, NBP, and optional invasive pressure, temperature, and CO2; when docked to a host IntelliVue monitor it seamlessly hands off all measurements, trends, and patient data as an MMS. The X2’s 3.5-inch touchscreen and configurable SmartKeys give clinicians immediate access to parameters and alarm controls without interrupting patient monitoring.

    Display
    3.5-inch TFT LCD touchscreen, QVGA

    Parameters Monitored
    ECG (3/5/6/10-lead), Arrhythmia, ST, QT/QTc, Respiration, SpO2, NBP, Temp (opt.), IBP (opt.), CO2 (opt.)

    Patient Population
    Adult, Pediatric, Neonatal

    Battery / Portability
    Rechargeable M4607A battery; up to ~3 hrs standalone; up to ~6 hrs with Battery Extension

    Device Weight
    1.98–2.64 lbs (depending on options)

    Connectivity
    Wired LAN, built-in WLAN, Short Range Radio (SRR), MSL connector

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90 (MMS mode)

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue X2. Contact us at 855-477-8866 or cs@iprmed.com.

  • RecertifiedQuick View

    Philips IntelliVue MX750 Patient Monitor

    The Philips IntelliVue MX750 is a high-acuity bedside patient monitor designed for intensive care, cardiac care, anesthesia, and neonatal environments. Built around a 19-inch Full HD projected capacitive touchscreen, the MX750 supports up to 12 simultaneous waveforms and connects to the full IntelliVue Multi-Measurement Module ecosystem for plug-and-play parameter expansion. The monitor combines advanced alarm management, enterprise-grade cybersecurity, and direct bedside access to hospital applications via HTML5 and Citrix, making it a capable platform for demanding ICU and OR workflows.

    Display
    19″ Full HD LCD (TFT), 1920 × 1080, projected capacitive touch

    Waveforms
    Up to 12 simultaneous

    Patient Population
    Adult, Pediatric, Neonatal

    Module Slots
    Up to 8 (with 2 FMX-4 racks)

    Connectivity
    100BaseT LAN, RS232, USB, 802.11 wireless (optional), HTML5/Citrix

    Notable Features
    RFID/NFC user authentication, Advanced Event Surveillance, Alarm Advisor, Visual Patient Avatar, Early Warning Scoring

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue MX750. Contact us at 855-477-8866 or cs@iprmed.com.

  • Recertified
    Quick View

    Philips IntelliVue MX40 Wearable Patient Monitor | Telemetry

    The Philips IntelliVue MX40 is a patient wearable monitor designed to provide continuous ECG monitoring, optional FAST SpO2, and impedance respiration for ambulatory patients throughout a hospital or care unit. Part of Philips’ IntelliVue family, the MX40 transmits real-time data wirelessly to the IntelliVue Information Center iX, enabling clinicians to maintain continuous oversight while patients move freely. Its 2.8″ color touchscreen, disinfectant-resistant housing, and flexible battery configuration make it well-suited for telemetry wards, step-down units, and progressive care environments.

    Display
    2.8″ color touchscreen, up to 5 screen formats

    Parameters Monitored
    ECG, Heart Rate, SpO2 (optional), Pulse Rate, Impedance Respiration, ST, QT

    ECG Lead System
    Standard, EASI, or Hexad — selectable in one device

    Battery / Power
    Three AA alkaline batteries or rechargeable lithium-ion battery pack (WLAN model: Li-ion only)

    Wireless Connectivity
    1.4 GHz Smart-hopping (WMTS), 2.4 GHz Smart-hopping, or 802.11 a/b/g WLAN — model dependent

    Infection Control
    Case design withstands high-level disinfectants including periodic sterilization

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue MX40. Contact us at 855-477-8866 or cs@iprmed.com.