IPR Medical

  • -12%
    New
    Quick View

    Philips Avalon CL Wireless Ultrasound Transducer (866076)

    Original price was: $1,695.00.Current price is: $1,495.00.

    The Philips Avalon CL Wireless Ultrasound Transducer (866076) is the cableless fetal heart rate transducer in the Avalon CL Fetal Transducer System — a Smart Transducer with an onboard microprocessor that captures, processes, and digitally transmits the fetal heart rate signal directly to the Avalon fetal monitor. Its seven-crystal array (six crystals arranged around the perimeter with one in the center, in equilateral triangle geometry) delivers uniform acoustic coverage and strong cardiac detection with minimal repositioning, making it especially effective for twins, triplets, and active labor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same measurement performance as wired Smart Transducers at ranges up to 100 m (300 ft) line of sight.

    The 866076 supports Cross-Channel Verification (CCV) to prevent maternal-fetal heart rate confusion, Fetal Movement Profile (FMP) for high-risk pregnancy monitoring, and automatic channel assignment (FHR1/FHR2/FHR3) when multiple transducers are in use. It is watertight for underwater monitoring, weighs approximately 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic pairing and battery recharging.

    IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.

  • -7%
    Recertified
    Quick View

    Philips Avalon CL Wireless Transducer Base Station (866074)

    Original price was: $2,695.00.Current price is: $2,495.00.

    The Philips Avalon CL Wireless Transducer Base Station (866074) is the hub of the Philips Avalon CL cableless fetal monitoring system — the docking station, charger, and wireless gateway that transforms a wired Avalon fetal monitor into a fully cableless L&D solution. A single 866074 base station docks up to three cableless fetal transducers (866075 Toco+ MP, 866076 Ultrasound, and 866077 ECG/IUP) plus one maternal parameters slot for an IntelliVue CL Pod or range extension module, with a total assignment capacity of four CL transducers and two CL Pods. It connects to any Philips Avalon FM20, FM30, FM40, or FM50 fetal monitor via the fetal sensor socket — or to the rear telemetry connectors on the FM40 and FM50 — and delivers a line-of-sight operating range of up to 100 m (300 ft).

    Docked transducers and pods are assigned and recharged automatically, so labor teams can grab a patient-ready device and apply it with no setup. The 866074 base station is required for all Avalon CL transducers and pods. IPR Medical sells, buys, repairs, and stocks parts for the Philips Avalon CL system — including base stations, transducers, antennas, power supplies, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips Compatible M1356A Fetal Ultrasound Transducer | Series 50

    $295.00

    This is an aftermarket-compatible wide-beam Doppler ultrasound transducer designed to function as a direct replacement for the M1356A fetal ultrasound transducer used with the Philips Series 50 family of fetal monitors (cardiotocographs), including the Series 50 A (M1351A) and the Series 50 IP-2 (M1353A). It is applied externally to the maternal abdomen and uses a wide-beam Doppler ultrasound element to detect fetal heart sounds, which the host monitor then processes through its auto-correlation algorithm to produce a continuous fetal heart rate (FHR) trace. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.

    Device Type
    Aftermarket-compatible external wide-beam Doppler ultrasound transducer for fetal heart rate (FHR)

    Replaces / Cross Reference
    M1356A fetal ultrasound transducer (also referenced as part 80310120)

    Compatible Monitors
    Philips Series 50 A (M1351A Single and Dual Ultrasound Twins), Series 50 IP-2 (M1353A), and earlier Philips/HP M1350 series fetal monitors

    Patient Population
    Antepartum (from approximately 20–25 weeks gestation) and intrapartum monitoring

    Connector
    Keyed round multi-pin connector compatible with the US, US1, or US2/ECG socket on the Series 50 monitor

    Mounting
    Snap-clip belt fixing onto compatible reusable fetal monitoring belts (e.g., M1562A); transducer knob adapter (M1356-43201) optional

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Series 50 fetal monitor family, including aftermarket-compatible fetal ultrasound transducers for the M1356A. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips Compatible M1355A External Toco Transducer | Series 50

    $295.00

    The Philips M1355A is the external tocodynamometer (Toco) transducer used with the Philips Series 50 family of fetal monitors (cardiotocographs), including the Series 50 A (M1351A) and the Series 50 IP-2 (M1353A). It uses a strain-gauge–based pressure sensor strapped over the fundus of the maternal abdomen to detect the duration, frequency, and relative intensity of uterine contractions, and it pairs with the M1356A ultrasound transducer to provide a complete external CTG trace.

    Device Type
    External tocodynamometer (Toco) transducer for non-invasive uterine activity monitoring

    Compatible Monitors
    Philips Series 50 A (M1351A Single and Twins), Series 50 IP-2 (M1353A), and earlier Philips/HP M1350 fetal monitors

    Patient Population
    Antepartum and intrapartum monitoring of uterine activity

    Connector
    Keyed round multi-pin connector to the dedicated Toco socket on the Series 50 monitor

    Mounting
    Snap-clip to M1562A reusable transducer belt; transducer knob adapter (M1356-43201) optional

    Housing Color Variants
    Brown (M1355-60001) and Blue (M1355-60011) — color matches monitor housing

    IPR Medical buys, sells, repairs, and stocks parts for the Philips M1355A external Toco transducer. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips Compatible Wireless Toco Transducer for Philips Avalon | M2725A

    $1,395.00

    This is an aftermarket-compatible cordless Toco transducer designed to function as a direct replacement for the M2725A wireless Toco fetal transducer used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50) when paired with the Avalon CTS cordless transducer base station (M2720A). It uses a strain-gauge pressure sensor to detect uterine activity by evaluating the hardness of the maternal abdomen during labor, transmitting the signal wirelessly to the CTS base so the patient retains freedom of movement during antepartum testing and labor and delivery. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.

    Device Type
    Aftermarket-compatible cordless (wireless) external Toco transducer for fetal/maternal monitoring

    Replaces / Cross Reference
    M2725A cordless Toco transducer (also referenced as part 862488)

    Compatible Monitors
    Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) — used together with the Avalon CTS base station (M2720A)

    Patient Population
    Antepartum testing and labor and delivery; ambulatory patients within the CTS base station’s coverage area

    Key Features
    Cordless operation, lightweight handheld form factor, waterproof housing for shower/bath use during labor, on-board status indicators

    Mounting
    Snap-clip belt fixing onto compatible reusable or waterproof fetal monitoring belts

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Cordless Transducer System (CTS), including aftermarket-compatible wireless Toco transducers for the M2725A. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips Avalon Ultrasound Fetal Transducer

    $1,475.00

    The Philips Avalon Ultrasound Fetal Transducer is a state-of-the-art device designed to deliver precise and continuous monitoring of fetal heart rate and activity. This advanced transducer leverages cutting-edge ultrasound technology to ensure accurate and reliable data, which is crucial for making informed clinical decisions during labor and delivery. Its ergonomic design and lightweight construction ensure patient comfort and ease of use for healthcare providers. The Philips Avalon Ultrasound Fetal Transducer integrates seamlessly with existing Philips fetal monitoring systems, providing a cohesive and efficient workflow in maternity wards. The device features a durable, high-quality build, ensuring consistent performance even in the most demanding clinical settings. Real-time, clear displays and alerts keep healthcare providers informed of any changes in fetal status, allowing for timely interventions. The transducer’s intuitive interface simplifies setup and operation, reducing training time and enhancing overall efficiency. Invest in the Philips Avalon Ultrasound Fetal Transducer for unparalleled accuracy, reliability, and comfort in fetal monitoring.

     

    Brand new units may be available. Please contact us directly for more information.

  • Philips Avalon Toco+ MP Fetal Transducer (M2735A) | DECG/MECG/IUP

    $1,495.00

    The Philips Avalon Toco+ MP Transducer (M2735A) is the most versatile wired Smart Transducer in the Avalon family — it measures uterine activity via external Toco, captures maternal pulse with built-in Smart Pulse, and accepts adapter cables for direct fetal ECG (DECG), maternal ECG (MECG), or intrauterine pressure (IUP). One transducer covers four measurement modes, which is why labor and delivery floors keep the M2735A on hand even when most patients are monitored externally.

    The Toco+ MP connects to any of the four fetal sensor sockets on Avalon FM20, FM30, FM40, or FM50 monitors via a standard D-shaped connector. Smart Pulse is always active when the transducer is applied, feeding maternal pulse into the monitor’s Cross-Channel Verification (CCV) feature to reduce the risk of mistaking maternal pulse for fetal heart rate. When DECG, MECG, or IUP monitoring is needed, the user simply plugs the appropriate adapter cable into the transducer’s auxiliary connector — the monitor automatically detects the mode.

    OEM Part Number
    M2735A (989803143681)

    Measurements
    Toco, Smart Pulse, DECG, MECG, IUP

    Compatible Monitors
    Avalon FM20, FM30, FM40, FM50

    Connector
    D-shaped (plug-and-play to any fetal sensor socket)

    Auxiliary Connector
    7-pin D-type for DECG/MECG/IUP adapter cables

    Smart Pulse
    Built-in, no separate SpO2 or MECG sensor required

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Toco+ MP Transducer (M2735A). Contact us at 855-477-8866 or cs@iprmed.com.

    Also available from IPR Medical:
    Philips M2734A / M2734B Smart Toco MP Transducer — wired external Toco with Smart Pulse  | 
    Philips Avalon Ultrasound Fetal Transducer (M2736A) — wired US transducer for external FHR  | 
    Philips Avalon CL Wireless Toco+ MP (866075) — cableless equivalent  | 
    Philips Avalon CL Wireless ECG/IUP (866077) — cableless DECG/MECG/IUP  | 
    Philips Avalon FM50 Fetal Monitor — host monitor

  • Philips M2734A / M2734B Smart Toco MP Transducer | Avalon

    $1,395.00

    The Philips M2734A and M2734B are wired Smart Toco MP transducers used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50). They combine two parameters in a single sensor — external uterine activity (Toco) and maternal pulse (MP) — and enable the Avalon platform’s Smart Pulse automated coincidence detection, which cross-checks the maternal pulse against the fetal heart rate to confirm the host monitor is not inadvertently tracking maternal heart rate as fetal. The M2734B is the successor revision to the M2734A and is functionally interchangeable on the Avalon Toco socket; both are auto-identifying via the Smart-interface (pink) connector and carry internal calibration data storage.

    Device Type
    Wired dual-parameter Smart Toco MP transducer (uterine activity + maternal pulse)

    Models
    M2734A (original Smart Toco MP) and M2734B (successor revision); both share the same role and Avalon socket

    Compatible Monitors
    Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) at supported software revisions

    Connector
    Wired Smart-interface (pink) connector to the dedicated Toco socket on the Avalon host monitor

    Key Features
    Dual-parameter Toco + maternal pulse, Smart Pulse coincidence detection, waterproof housing for shower/bath use, latex-free, auto-identification, internal calibration data storage

    Patient Population
    Antepartum testing and labor and delivery

    IPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon fetal monitor family, including the M2734A and M2734B Smart Toco MP transducers. Contact us at 855-477-8866 or cs@iprmed.com.

  • Philips Avalon Ultrasound Transducer

    $1,995.00

    The Avalon Ultrasound system by Philips is a top-tier solution designed for precise and reliable fetal and maternal monitoring. Featuring advanced ultrasound technology, it ensures accurate and continuous monitoring of fetal heart rate and uterine activity, providing critical insights for informed clinical decisions. Its user-friendly interface and intuitive controls make setup and operation straightforward, allowing healthcare professionals to focus on patient care. The Avalon Ultrasound system boasts seamless integration with existing hospital networks, enhancing workflow efficiency and enabling real-time data sharing. Its compact, ergonomic design ensures easy portability and adaptability to various clinical settings, from labor and delivery rooms to intensive care units. Constructed with high-quality materials, the system promises durability and consistent performance even in demanding environments. Advanced safety features and comprehensive monitoring capabilities make it an indispensable tool for ensuring the well-being of both mother and baby. Invest in the Philips Avalon Ultrasound system for unparalleled accuracy, efficiency, and reliability in fetal and maternal healthcare.

     

    Brand new units may be available. Please contact us directly for more information.

  • Philips Avalon CL Wireless Toco+ MP Transducer (866075)

    $1,995.00

    The Philips Avalon CL Wireless Toco+ MP Transducer (866075) is the cableless uterine activity transducer in the Avalon CL Fetal Transducer System — measuring uterine contractions via external Toco while simultaneously capturing maternal pulse through integrated Smart Pulse technology. It also includes a multi-purpose connector that accepts maternal ECG, fetal ECG (DECG), or intrauterine pressure (IUP) sensors, making the 866075 one of the most versatile transducers on the L&D floor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same performance as wired Smart Transducers while letting mothers walk, shower, or reposition during labor at ranges up to 100 m (300 ft) line of sight.

    The 866075 is watertight for underwater monitoring, weighs only about 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic pairing and battery recharging.

    IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.

  • -19%
    New
    Quick View

    Compatible GE Corometrics Toco Fetal Transducer, Wings, 2264LAX

    Original price was: $325.00.Current price is: $264.00.

    Reliable fetal monitoring starts with the right transducer. This compatible toco (tocodynamometer) transducer is a direct replacement for the GE Corometrics 2264LAX, providing accurate external monitoring of uterine contraction frequency, duration, and relative pressure throughout labor and delivery. The wing (loop) style connector secures firmly into GE Corometrics fetal monitors and stays fixed to the maternal abdomen with a standard monitoring belt. The low-profile, flat design prioritizes patient comfort during extended monitoring sessions, while the watertight construction withstands routine cleaning and disinfection between patients.

    This transducer features a round, keyed 12-pin distal connector, a 10 ft gray cable, and is manufactured latex-free and DEHP-free. It is compatible with the following GE Corometrics fetal monitor models:

    Series
    Compatible Models

    100 Series
    116, 118, 120, 128, 129, 130, 145, 150, 151, 155

    170 Series
    170, 171, 172, 173, 174

    250 Series
    250, 250cx, 256cx, 259, 259cx

    300 Series
    340

    IPR Medical stocks this compatible replacement transducer so your labor and delivery team can keep monitoring without delays. Call us at 855-477-8866 or email cs@iprmed.com.

  • -13%
    New
    Quick View

    Compatible GE Corometrics TOCO Fetal Transducer, Knob, 2264HAX

    Original price was: $375.00.Current price is: $325.00.

    Reliable fetal monitoring starts with the right transducer. This compatible toco (tocodynamometer) transducer is a direct replacement for the GE Corometrics 2264HAX, providing accurate external monitoring of uterine contraction frequency, duration, and relative pressure throughout labor and delivery.

    The knob (button) style connector threads securely into the corresponding port on GE Corometrics fetal monitors and locks the transducer in place against the maternal abdomen with a standard monitoring belt. The low-profile, flat design prioritizes patient comfort during extended monitoring sessions, while the watertight construction withstands routine cleaning and disinfection between patients.

    This transducer features a round, keyed 12-pin distal connector, a 10 ft gray cable, and is manufactured latex-free and DEHP-free. It is compatible with the following GE Corometrics fetal monitor models:

    Series
    Compatible Models

    100 Series
    116, 118, 120, 128, 129, 130, 145, 150, 151, 155

    170 Series
    170, 171, 172, 173, 174

    250 Series
    250, 250cx, 256cx, 259, 259cx

    300 Series
    340

    IPR Medical stocks this compatible replacement transducer so your labor and delivery team can keep monitoring without delays. Call us at 855-477-8866 or email cs@iprmed.com.