Baxter Auto Syringe AS50 Infusion Pump

$1,995.00 Original price was: $1,995.00.$1,395.00Current price is: $1,395.00.

The Baxter Auto Syringe AS50 is a compact, single-channel syringe infusion pump designed for accurate continuous or intermittent delivery of intravenous solutions, drug solutions, whole blood, and packed red blood cells. It supports IV, intra-arterial, epidural, and subcutaneous routes, accepts standard disposable syringes from 1 mL to 60 mL across three manufacturers, and operates on internal rechargeable battery or AC charger for bedside, transport, and ambulatory use.

Pump Type Single-channel syringe infusion pump
Flow Rate Range 0.01 to 438 mL/hr (syringe-dependent)
Compatible Syringes B-D Plastic, Sherwood Monoject, and Terumo, 1–60 mL
Drug Library Configurable Protocol Library; 18 infusion modes
Connectivity DB-9 RS-232 serial port (remote monitoring/control)
Battery Internal rechargeable pack; 5 hr at 100 mL/hr or 12 hr at 2 mL/hr
Notable Features Bolus, titration, syringe recognition, keypad lock, backlight

IPR Medical buys, sells, repairs, and stocks parts for the Baxter Auto Syringe AS50 Infusion Pump. Contact us at 855-477-8866 or cs@iprmed.com.

SKU: baxter-auto-syringe-as50-infusion-pump Category: Brand:
Send In Baxter Auto Syringe AS50 Infusion Pump for Repair

Baxter Auto Syringe AS50 — Specifications


Manufacturer Baxter Healthcare Corporation
Model Auto Syringe AS50 Infusion Pump
Catalog Code 1M8550
Model Family (OEM-identified) Auto Syringe AS40, AS40A, AS50, and AS50A series; share the “900-Series” charger platform per OEM documentation
Device Classification Single-channel syringe infusion pump
Intended Use Continuous or intermittent infusion of intravenous solutions, drug solutions, whole blood, and packed red blood cells via IV, intra-arterial, epidural, or subcutaneous routes
Pump Mechanism DC motor-driven lead screw advancing a captured syringe plunger
Compatible Syringes B-D Plastic 1, 3, 5, 10, 20, 30, 60 mL; Sherwood Monoject 1, 3, 6, 12, 20, 35, 60 mL; Terumo 1, 3, 5, 10, 20, 30, 60 mL
Flow Rate Range 0.01 mL/hr to 438 mL/hr, depending on syringe size and manufacturer
Configurable Rate Range Limits High (max for syringe), Medium (120 mL/hr / 2 mL/min), Low (15 mL/hr / 0.25 mL/min)
Flow Rate Accuracy ±3% of full-scale plunger travel (not including syringe tolerance)
Volume Accuracy ±3%, or ±0.007 inches of travel, whichever is greater (not including syringe tolerance)
Deliverable Volume Full syringe volume for 1–60 mL syringes
Infusion Modes 18 modes total — 15 continuous (mL/hr, mL/min, Units/hr, Units/min, mUnits/hr, mUnits/min, mg/hr, mg/min, mcg/hr, mcg/min, mg/kg/hr, mg/kg/min, mcg/kg/hr, mcg/kg/min, Custom Dilution) and 3 timed (Single Dose, Manual Schedule, Auto Schedule). See the Description Tab for clinical capability detail.
Drug Library Configurable Protocol Library with named protocols and protocol groups
Bolus Capability Pre-programmable bolus with configurable maximum bolus rate
Occlusion Detection Configurable pressure sensitivity; LINE OCCLUDED alarm
Syringe Recognition Automatic syringe size detection via barrel diameter sensor; configurable Size Override
Display Self-prompting multi-field LCD with eight data fields; configurable backlight
Status Panel Nine-LED array (Run, Alert, Battery, On Charge, Standby, Lock, System)
User Interface Elastomeric numeric keypad with tactile feedback; Lock and Auto Lock functions
Event Log 253-event capacity in EEPROM (243 event log + 10 fail-safe log); circular buffer; accessible via serial port
Connectivity DB-9 RS-232 serial communication port; remote monitoring is always available, remote control is a configurable option
Power AC: 105–125 V, 60 Hz (via battery charger); DC: internal rechargeable battery pack
Battery Internal 5-cell rechargeable pack; 5 hr at 100 mL/hr or 12 hr at 2 mL/hr (60 mL syringe), following ≥16 hr charge; Baxter recommends replacement every 16 months
Compatible Chargers “900 Series” charger model CAS40-01-900; Multi-Charger product code 1M8563 (also charges AS40A series)
Mounting Removable IV pole clamp and built-in IV pole loop; tabletop use also supported
Construction Water-resistant high-impact plastic case with removable elastomeric protective bumpers
Dimensions Approx. 3.4 in W × 2.6 in D × 10 in H
Weight Approx. 3.2 lbs
Operating Temperature 50°F to 104°F
Audio Alerts Piezo ceramic transducer; 4 kHz normal tones, 4 kHz / 2 kHz oscillating fail-safe alarm; configurable audio range
Regulatory FDA Class II, Product Code FRN, Regulation 21 CFR 880.5725 (Infusion Pump). Federal (USA) law restricts this device to sale by or on the order of a physician.
Manufacturer Service Status Baxter has ended OEM service support for the AS50 platform; secondary-market service and parts remain available
FDA Device Corrections FDA recall records for the Baxter Auto Syringe AS50 Infusion Pump are listed in the FDA Medical Device Recalls Database. See the Description Tab for summary detail and links to the FDA’s official resources.

IPR Medical buys, sells, repairs, and stocks parts for the Baxter Auto Syringe AS50 Infusion Pump. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.


What Our Customers Say

“I’ve been using IPR (Infusion Pump Repair) for about five years, and their service has been consistently outstanding. The team is incredibly knowledgeable and stands behind all their work. They respond quickly and make the repair process for our equipment, particularly our Baxter AS40 and AS50 pumps, seamless and hassle-free. The staff is always friendly, helpful, and super responsive. I highly recommend their services to anyone in need of reliable equipment repair and maintenance.”

— Jeremy J., Google review

Read more customer testimonials

Trademark Notice: Baxter, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Baxter.

Overview

The Baxter Auto Syringe AS50 Infusion Pump is a compact, single-channel syringe-driven infusion pump intended for accurate continuous or intermittent delivery of intravenous solutions, drug solutions, whole blood, and packed red blood cells. The pump is indicated for IV, intra-arterial, epidural, and subcutaneous administration, and it can be piggybacked into an ongoing infusion line to deliver secondary solutions. Programmable infusion rates span 0.01 to 438 mL/hr depending on the syringe selected, and the device accepts standard disposable syringes from 1 mL to 60 mL across three OEM-supported manufacturers — B-D Plastic, Sherwood Monoject, and Terumo. The AS50 sits within Baxter’s Auto Syringe family alongside the AS40A  which share a common “900-Series” charger and battery platform per OEM documentation. Although Baxter has ended factory service for the AS50, the platform continues to be supported on the secondary market for facilities that have standardized on it for anesthesia, NICU, critical care, and procedural settings where syringe-driven precision dosing is preferred to large-volume pumping.


Display and User Interface

The AS50 uses a self-prompting multi-field LCD that organizes infusion data into eight discrete fields, each with left-side annunciators identifying the data type and right-side annunciators identifying the unit of measure. The current programmable field flashes to indicate it is open for entry, and the bottom two-line text area carries text prompts and infusion messages. A configurable backlight is on whenever the charger is connected and can also be configured to illuminate for a specified interval after each keypress on battery power. Above the display, a nine-LED status panel reports operating state at a glance: three Run lights flash in a falling-drop sequence during delivery, a single top Run light flashes during interval counting in scheduled modes, and the Run lights pulse in unison during bolus or purge. Distinct Alert, Battery, On Charge, Standby, Lock, and System indicators communicate alarm and configuration state without forcing the operator to read the LCD. The elastomeric numeric keypad provides tactile feedback and includes dedicated function keys for Bolus, Purge, Edit, Lock, Confirm, Clear, Start, and Stop, with arrow keys for incrementing values or moving between fields.


Drug Library and Dose Error Reduction

The AS50 implements dose error reduction primarily through its configurable Protocol Library feature, a set of named protocols that store frequently used programming data — default infusion mode, default concentration, default dose or rate, default bolus size, bolus prevention flag, and a bolus maximum rate ceiling — and that may be grouped into named libraries. When a protocol is selected during startup, the pump automatically pre-populates downstream programming steps and may skip the mode-selection step entirely if the protocol specifies a default mode. Protocols can also disable bolus delivery or cap bolus rate based on dosage units (such as mcg/kg/min), which is significant for high-alert infusions where an unintended large-volume push could be harmful. The pump supports 18 infusion modes in total: 15 continuous-delivery modes (mL/hr, mL/min, Units/hr, Units/min, mUnits/hr, mUnits/min, mg/hr, mg/min, mcg/hr, mcg/min, mg/kg/hr, mg/kg/min, mcg/kg/hr, mcg/kg/min, and Custom Dilution) and three timed modes (Single Dose, Manual Schedule, and Auto Schedule). Custom Dilution is particularly useful when a target rate and target weight-based dose are known but the drug must be reconstituted on the spot — the pump calculates the volume of drug to add to the infusion base solution to achieve the requested final concentration. Volume limits, body weight, drug concentration, and bolus parameters are all entered through a self-prompted numeric keypad sequence, and the pump performs out-of-range data tests on every Confirm keypress.


Software Versions and Platform Evolution

The AS50 belongs to Baxter’s Auto Syringe platform, a family that also includes the earlier AS40A. All members of the family share the “900-Series” charger interface per OEM documentation, which is why service-shop battery references such as 5601 and B11056 appear across multiple Auto Syringe models. The AS50 platform itself stores its application firmware and configuration data in onboard memory, and the active software and configuration version can be displayed from the Configuration Review menu. The Configuration Review groups options into VIEW LIBRARY (protocol library), VIEW MODES (allowed infusion modes), VIEW SYRINGES (enabled syringe manufacturers and sizes), VIEW DFAULTS (default values), VIEW MISC (miscellaneous including remote control), and VIEW ALERTS (alarm and alert behavior), plus a configurable identifier of up to eight characters that displays after the lamp test on power-up. Configuration changes and field-service procedures are documented in the OEM Service Manual and were typically performed by Baxter or by hospital biomedical engineering. Because Baxter has ended factory service on the AS50 platform, software-level changes today are made through authorized secondary-market service paths, and IPR Medical can advise on which configuration adjustments and protocol-library updates are still feasible on a given pump revision.


Battery, Mounting, and Portable Operation

The AS50 is built for portability. Its high-impact plastic case carries removable elastomeric bumpers for impact protection, the unit weighs approximately 3.2 lbs, and at roughly 3.4 inches wide by 2.6 inches deep by 10 inches tall it fits comfortably on an IV pole, a transport sled, or a tabletop. Power comes from an internal 5-cell rechargeable battery pack; the pump is not intended to operate on AC power alone. Following a minimum 16-hour charge, Baxter specifies approximately 5 hours of operation at 100 mL/hr or 12 hours at 2 mL/hr using a 60 mL syringe, with actual runtime depending on syringe size, infusion rate, alarm activity, and battery age. The AC charger is the wall-mount “900 Series” model CAS40-01-900, which is unregulated and is shared with the AS40A series; the same battery platform is also serviced by the 1M8563 Multi-Charger. Baxter recommends battery replacement every 16 months as part of a regular preventive-maintenance program, since aged NiMH packs are a leading source of premature low-battery alarms and runtime shortfalls. The pump ships with an IV pole clamp and a built-in IV pole loop. The keypad supports a Lock function and a configurable Auto Lock that engages automatically after a configurable period, helping prevent unintended programming changes during transport.


Event Logging, Alarms, and Remote Monitoring

The AS50 records up to 253 events in non-volatile EEPROM, partitioned into a 243-entry event log and a separate 10-entry fail-safe log. Each log is maintained as a circular buffer, so once full, the oldest event is overwritten by the newest. Both logs are read out through the DB-9 RS-232 serial port using the command set documented in the OEM Programmer’s Manual. The serial interface also supports remote monitoring of infusion totals, program values, and operational status whenever the pump is in operation, and — when the REMOTE CONTROL configuration option is enabled — supports remote control of pump operations from a host computer. The pump’s alarm system distinguishes alerts (operator-attention conditions such as PUMP IS IDLE, NEAR END, and CHECK SYRINGE) from alarms (delivery-stopping conditions such as LINE OCCLUDED and EMPTY) and from fail-safe alarms (numbered ERROR M and ERROR L codes that indicate master and slave processor faults). Audible alerting is delivered through a piezo ceramic transducer driven at 4 kHz for normal tones and at an oscillating 4 kHz to 2 kHz for fail-safe conditions, with a configurable audio range. For LINE OCCLUDED alarms, OEM guidance specifies relieving residual syringe pressure by releasing the plunger driver before clearing the occlusion, to avoid an unintentional bolus when the blockage is removed.


Service and Maintenance Considerations

Because Baxter has ended OEM service for the AS50 platform, ongoing maintenance has shifted to qualified third-party service organizations. The OEM-recommended periodic maintenance program consists of a daily check (lamp test, audible click on each keypress, and visual inspection of the syringe-mounting hardware), scheduled battery replacement every 16 months, periodic display-and-syringe-sensor checks, keypad checks, and battery voltage checks, all documented in the OEM Service Manual. Routine cleaning is performed with the OEM-approved cleaner list — solvents such as acetone, ammonia, benzene, methylene chloride, and ozone, as well as cleaners containing n-alkyl dimethyl ethylbenzyl ammonium chloride that are not on the approved list, must not be used because they damage the front panel. The AS50 must not be autoclaved, EtO sterilized, steam sterilized, or exposed to temperatures above 104°F. Repeated incorrect syringe-size identification by the Syringe Recognition feature is an OEM-flagged indicator that the pump should be removed from service for investigation, since it can signal a sensor fault or a dimensional change in the syringe. IPR Medical handles repair, calibration, battery replacement, and parts replacement for AS50 pumps, and can advise on device disposition when a unit is approaching end-of-life and replacement with a current-generation Baxter Novum IQ Syringe Pump or comparable platform may be more cost-effective than continued repair.


FDA Device Corrections and Safety Bulletins

The Baxter Auto Syringe AS50 Infusion Pump has been the subject of at least one FDA-classified Class 2 device recall affecting the AS50 platform, listed in the FDA Medical Device Recalls Database. Class 2 designations are used when use of, or exposure to, a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote. Because the AS50 has been in clinical service for many years and Baxter has ended OEM support for the platform, facilities that continue to operate AS50 pumps should periodically verify that no additional safety communications, OEM Urgent Field Safety Notices, or correction letters apply to their specific catalog code, configuration, or pump revision. Field-replaceable wear items — particularly the rechargeable battery, the barrel-clamp assembly, the plunger driver assembly, and the keypad overlay — are the most common contributors to operational complaints on aging AS50 fleets, and many of those issues are addressed through preventive maintenance rather than through formal correction action.

Recommended actions: Identify the catalog codes, model variants (AS50 vs. AS50A), and configuration codes of every Auto Syringe pump in service. Search the FDA Medical Device Recalls Database for “Baxter Auto Syringe AS50” and review every Class 1 and Class 2 record to confirm whether your specific pumps are affected. Confirm that batteries have been replaced within the OEM-recommended 16-month interval. Verify that current preventive-maintenance documentation, including syringe-sensor checks and lamp tests, is on file for each pump. If your facility has not received OEM communications because Baxter has ended platform support, contact IPR Medical for help locating the most recent OEM Urgent Field Safety Notice text and confirming whether your serial-number range is in scope.

Because FDA device corrections and safety communications may be updated or expanded after the date of this listing, IPR Medical recommends that facilities also check the FDA’s official resources directly to ensure they have the most current information.

FDA resources for further review:
FDA Medical Device Recalls Database  |
FDA Medical Device Safety


IPR Medical — Buy, Sell, Repair, and Parts

IPR Medical supports the Baxter Auto Syringe AS50 platform with full purchase, resale, repair, and parts services. We buy AS50 pumps individually or by fleet from facilities transitioning to current-generation syringe-pump platforms; we sell tested, refurbished AS50 units with calibration documentation; and we repair AS50 pumps for facilities that have standardized on the platform and need to keep it operational. Because Baxter has ended OEM service on the AS50, IPR Medical’s secondary-market support is one of the more practical paths to keeping these pumps in clinical service: we stock the high-wear field-replaceable parts (batteries, pole clamps, barrel-clamp assemblies, plunger driver assemblies, keypads, AC chargers, and front and rear case assemblies), we perform calibration and functional verification, and we can advise on whether continued repair or fleet replacement makes more economic sense for your facility’s specific configuration and case-mix.

IPR Medical buys, sells, repairs, and stocks parts for the Baxter Auto Syringe AS50 Infusion Pump. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Baxter, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Baxter.

Weight 5 lbs
Dimensions 14 × 10 × 10 in
Condition

Recertified (Refurbished)
Patient Ready

Compatible Parts and Accessories

IPR Medical stocks a range of compatible parts and accessories for the Baxter Auto Syringe AS50 Infusion Pump.Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific configuration.


IV Extension Sets (OEM-Recommended for AS50)

Micro-Volume IV Extension Set, 36 in (2N3345) Baxter 2N-series Micro-Volume extension set; recommended for low-rate AS50 infusions; OEM P/N 2N3345.
High Flow Rate IV Extension Set, 36 in (2N3346) Baxter 2N-series high-flow extension set, 36 in length; OEM P/N 2N3346.
Micro-Volume IV Extension Set with 0.22 µm Filter, 36 in (2N3347) Baxter 2N-series Micro-Volume extension with inline 0.22 µm filter, 36 in length; OEM P/N 2N3347.
Micro-Volume IV Extension Set, 60 in (2N3348) Baxter 2N-series Micro-Volume extension set, 60 in length; OEM P/N 2N3348.
High Flow Rate IV Extension Set, 60 in (2N3349) Baxter 2N-series high-flow extension set, 60 in length; OEM P/N 2N3349.
Micro-Volume IV Extension Set with 0.22 µm Filter, 60 in (2N3350) Baxter 2N-series Micro-Volume extension with inline 0.22 µm filter, 60 in length; OEM P/N 2N3350.

Compatible Syringes

B-D Plastic Syringes 1, 3, 5, 10, 20, 30, and 60 mL plastic disposable syringes; OEM-supported manufacturer; specific size enabled in pump configuration.
Sherwood Monoject Syringes 1, 3, 6, 12, 20, 35, and 60 mL disposable syringes; OEM-supported manufacturer; note 6/12/35 mL sizes (not 5/10/30) per Monoject sizing.
Terumo Syringes 1, 3, 5, 10, 20, 30, and 60 mL disposable syringes; OEM-supported manufacturer.

Power and Battery

Internal Rechargeable Battery Pack 5-cell rechargeable pack used across the OEM-identified Auto Syringe AS40, AS40A, AS50, and AS50A series; commonly cross-referenced as Baxter 5601 and B11056. Baxter recommends replacement every 16 months. Contact IPR Medical to confirm the specific OEM revision matching your pump.
“900 Series” AC Battery Charger (CAS40-01-900) Wall-mount unregulated battery charger; shared platform across AS40A and AS50 series; OEM model number CAS40-01-900.
Multi-Charger (1M8563) Multi-bay charger compatible with AS40A and AS50 series Auto Syringe pumps per OEM documentation; OEM product code 1M8563.
Battery Cover Replacement battery cover for AS50; OEM reference AAS5001473.

Field-Replaceable Units (FRU)

Pole Clamp Assembly Removable IV pole clamp assembly; OEM reference AAS5001500RP.
Barrel Clamp Assembly Externally mounted barrel clamp that secures the syringe barrel and reads barrel diameter for syringe recognition; OEM reference AAS5001503RP.
Lower Plunger Driver Assembly Lower plunger assembly that captures the syringe plunger and translates motor rotation into linear plunger advance; OEM reference AAS5001508RP.
Front Case Assembly Replacement front housing; OEM reference AAS5001522RP.
Rear Case Assembly Replacement rear housing; OEM reference A069160000RP.
Rubber Keypad Overlay Elastomeric tactile-feedback keypad overlay; OEM reference DAS5001401.
Carbon Keypad Overlay Carbon overlay layer used beneath the rubber keypad overlay; OEM reference DAS5001402.
Power Connector Internal power connector assembly; OEM reference AAS4001522.
End Cap, Black Rubber (Bumper) Removable elastomeric protective bumper; OEM reference DAS4005481.

Service and Documentation

RS-232 Serial Cable (DB-9) Standard 9-pin DB-9 RS-232 cable used between the AS50 serial port and a host computer for remote monitoring or remote control. Contact IPR Medical for the specific cable specification matching your host configuration.
Operator’s, Programmer’s, and Service Manuals Auto Syringe AS50 Infusion Pump Operator’s Manual (07-19-B3-430), Programmer’s Manual, and Service Manual. Contact IPR Medical for assistance locating archived OEM documentation.

IPR Medical buys, sells, repairs, and stocks parts for the Baxter Auto Syringe AS50 Infusion Pump. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.