GE Healthcare TS-F1-H Compatible Adult Finger Clip SpO2 Sensor, Ohmeda OXY-F1-H, Hard Shell, Reusable, 3.3 ft (1.0 m)
The GE Ohmeda SpO2 sensor TS-F1-H compatible replacement is a reusable, aftermarket adult hard-shell finger clip sensor (not OEM) that replaces the Ohmeda OXY-F1-H, built to OEM fit, form, and function.
| Sensor Type | Finger Clip, Hard Shell |
| Patient Size | Adult |
| SpO2 Technology | Ohmeda |
| Cable Length | 3.3 ft (1.0 m), short sensor |
| Lifecycle | Reusable |
Works with: Datex-Ohmeda 3700/37xx-series, 3800, 3900/3900P, and TuffSat pulse oximeters, the 4700 and 5250 RGM, and GE CARESCAPE ONE and V100 monitors configured with Ohmeda-type SpO2. See the Specifications tab for the full list. Browse more SpO2 cables and sensors.
IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda and GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
| Product Type | Compatible Replacement (Aftermarket, Not OEM) |
| IPR Medical SKU | SS-010-AF10 |
| OEM Reference | GE Healthcare TS-F1-H / Ohmeda OXY-F1-H |
| Sensor Type | Finger Clip, Hard Shell |
| Patient Size | Adult |
| SpO2 Technology | Ohmeda |
| Cable Length | 3.3 ft (1.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 per Bag |
Compatible Monitor Models
Device must be configured with Ohmeda-type SpO2.
| Manufacturer / Series | Compatible Models |
| Datex-Ohmeda Pulse Oximeters | 3700, 3710, 3740, 3770, 3775; 37xx Series; 3800, 3900, 3900P; TuffSat |
| Datex-Ohmeda Monitors | 4700; 5250 RGM (Respiratory Gas Monitor) |
| GE Healthcare CARESCAPE | CARESCAPE ONE, CARESCAPE V100 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| GE Healthcare | TS-F1-H |
| Ohmeda | OXY-F1-H |
| Datex-Ohmeda | 6051-6000-155 |
| Sage Services Group | P05-11M |
| Tenacore | TP1812SP, TCPS-1612-0322 |
| Unimed | U403-02 |
IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda pulse oximeters and GE patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, Masimo, or any other manufacturer or supplier named on this page. GE Healthcare, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the GE TS-F1-H Compatible Adult Finger Clip SpO2 Sensor?
The GE Healthcare TS-F1-H compatible SpO2 sensor is a reusable, aftermarket adult hard-shell finger clip pulse oximetry sensor for Datex-Ohmeda and GE equipment that uses Ohmeda SpO2 technology. It replaces the Ohmeda OXY-F1-H and GE TS-F1-H adult finger sensors and uses a short 3.3 ft (1.0 m) cable with the Ohmeda “H” style connector. It is a compatible replacement, not an original GE or Datex-Ohmeda part, and it is built to OEM fit, form, and function.
Compatible Monitor Models
This compatible sensor is confirmed for use with Datex-Ohmeda 3700, 3710, 3740, 3770, and 3775 pulse oximeters and other 37xx-series units, the 3800, 3900, and 3900P pulse oximeters, the 4700 monitor, the 5250 respiratory gas monitor (RGM), and the TuffSat handheld oximeter. It is also listed for GE CARESCAPE ONE and CARESCAPE V100 monitors configured with Ohmeda-type SpO2. Because GE and Datex-Ohmeda equipment has used several SpO2 technologies and connector styles over the years, confirm your monitor’s SpO2 configuration and connector before ordering.
Design and Construction
The hard-shell finger clip holds the emitter and detector in consistent alignment on adult fingers, making it well suited for spot checks, OR and PACU use, and short-term continuous monitoring. The short 3.3 ft (1.0 m) cable keeps weight off the finger and connects to the oximeter directly or through a compatible extension cable, so a worn sensor can be replaced without replacing the extension. The sensor is reusable after cleaning and disinfection according to facility protocol and ships one per bag.
When to Replace Your Ohmeda Adult Finger Clip Sensor
Replace the sensor when the oximeter reports “sensor off,” “no probe,” or probe fault messages that persist with a known-good extension cable, when readings are erratic or the pleth waveform is weak on a well-perfused patient, or when the clip spring has weakened, the housing is cracked, the pad is torn, or the cable jacket is damaged near the clip or connector. Swapping in a known-good sensor quickly identifies whether the sensor or the cable is at fault.
Cross Reference and Interchange Part Numbers
This compatible Ohmeda adult finger clip SpO2 sensor, IPR Medical SKU SS-010-AF10, cross-references to GE Healthcare TS-F1-H, Ohmeda OXY-F1-H, and Datex-Ohmeda 6051-6000-155. It also interchanges with Sage Services Group P05-11M, Tenacore TP1812SP and TCPS-1612-0322, and Unimed U403-02. For TruSignal-equipped GE CARESCAPE and Dinamap monitors, see IPR Medical’s compatible TruSignal sensors and the GE TS-G3 interconnect cable, SKU SA-016-24TS.
Why Source SpO2 Sensors from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring and infusion equipment. We carry compatible Ohmeda, TruSignal, Masimo, and Nellcor SpO2 sensors and cables for GE and Datex-Ohmeda equipment, so biomedical and anesthesia technology teams can keep legacy oximeters and current monitors supplied from one source at lower cost than OEM. Our team can help identify each device’s SpO2 technology and support your equipment with in-house repair services.
IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda pulse oximeters and GE patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, Masimo, or any other manufacturer or supplier named on this page. GE Healthcare, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews