Nihon Kohden JC-906PA Compatible 3/6-Lead ECG Trunk Cable with Respiratory Rate, AHA, 8.2 ft (2.5 m)

$80.00

The Nihon Kohden JC-906PA compatible 3/6-lead ECG trunk cable (SKU ET-6013-NKB-A) is a reusable aftermarket replacement (not OEM) with respiratory rate, AHA designation, and an 8.2 ft (2.5 m) length, for use with Nihon Kohden BR-9XXP leadwires.

Lead Count 3/6-Lead
Feature Respiratory Rate
AHA/IEC Code AHA
Cable Length 8.2 ft (2.5 m)
Used With Nihon Kohden (BR-9XXP) Leadwires
Replaces Nihon Kohden JC-906PA

Works with: select Nihon Kohden BSM, Life Scope, PVM, and TEC models. See the Specifications tab for the full list. Browse more ECG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for patient monitors and ECG accessories. Call 855-477-8866 or email cs@iprmed.com.

SKU: ET-6013-NKB-A Categories: , Tags: ,
Send In Nihon Kohden JC-906PA Compatible 3/6-Lead ECG Trunk Cable with Respiratory Rate, AHA, 8.2 ft (2.5 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) ET-6013-NKB-A
Replaces OEM Part Nihon Kohden JC-906PA
Category Cables & Sensors > ECG/EKG
Product ECG Trunk Cable
Lead Count 3/6-Lead
Lead Placement Limb + Chest Lead
Feature Respiratory Rate
AHA/IEC Code AHA
Used With Nihon Kohden (BR-9XXP) Leadwires
Cable Length 8.2 ft (2.5 m)
Intended Use Monitoring
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Nihon Kohden BSM-73, BSM-73C, BSM-230K, BSM-1101, BSM-1101K, BSM-1102, BSM-1102K, BSM-1700 Series, BSM-2000, BSM-2101, BSM-2102, BSM-2300, BSM-2300 Life Scope I, BSM-2300 Series, BSM-2300 with YJ 230P, BSM-2300C, BSM-2301, BSM-2301C, BSM-2303, BSM-2303C, BSM-2304, BSM-2351, BSM-2351A, BSM-2351C, BSM-2353, BSM-2353C, BSM-2354A, BSM-3000, BSM-3000 Series, BSM-3000 with AY 631P, BSM-3000 with AY 633P, BSM-3000 with AY 651P, BSM-3000 with AY 653P, BSM-3101, BSM-3500, BSM-3532, BSM-3552, BSM-3562, BSM-3700, BSM-3733, BSM-3753, BSM-3763, BSM-4100, BSM-4100 Life Scope P, BSM-4100 Series, BSM-4101, BSM-4101K, BSM-4102, BSM-4102A, BSM-4103, BSM-4103K, BSM-4104, BSM-4111, BSM-4111K, BSM-4112, BSM-4113, BSM-4113K, BSM-4114, BSM-4114A, BSM-5000 Series, BSM-5100, BSM-5100 Life Scope A, BSM-5100 Series, BSM-5100 with YJ 510P, BSM-5105, BSM-5105K, BSM-5135, BSM-5135K, BSM-6000 Series, BSM-6000 with AY 631P, BSM-6000 with AY 633P, BSM-6000 with AY 651P, BSM-6000 with AY 653P, BSM-6301, BSM-6301C, BSM-6301K, BSM-6311, BSM-6312, BSM-6312-NKFL/ZA, BSM-6313, BSM-6331, BSM-6332, BSM-6333, BSM-6501, BSM-6501A, BSM-6501C, BSM-6501K, BSM-6531, BSM-6532, BSM-6533, BSM-6571, BSM-6572, BSM-6573, BSM-6701, BSM-6701C, BSM-6701K, BSM-6731, BSM-6732, BSM-6733, BSM-6771, BSM-6772, BSM-6773, BSM-7100, BSM-7102A, BSM-7200, BSM-7201K, BSM-7211K, BSM-8200, BSM-8201, BSM-8300, BSM-8301, BSM-8301A, BSM-8302, BSM-8302A, BSM-8500, BSM-8500A, BSM-8502, BSM-8502A, BSM-8800, BSM-8800A, BSM-9100, BSM-9100 with AY 631P, BSM-9100 with AY 633P, BSM-9100 with AY 651P, BSM-9100 with AY 653P, BSM-9100 with YJ 671P, BSM-9101, BSM-9172, BSM-9173, BSM-9510, BSM-9510 Life Scope M, BSM-9510K, BSM-9800 Life Scope S, BSS 9800K, Life Scope 6700 Series, Life Scope J, Life Scope LC BSM-3101K, Life Scope SVM 7200 Series, Life Scope TR, PVM 2700, PVM 2703, PVM-2701, TEC 8300, TEC 8321, TEC 8322, TEC 8332, TEC 8342, TEC 8352, Vismo PVM 2701, Vismo PVM 2703

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Nihon Kohden K922A, JC-906PA
AMC CB-85600
Sage T07-06-30M
Unimed NK-2509

IPR Medical buys, sells, repairs, and stocks parts for ECG trunk cables and the Nihon Kohden monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nihon Kohden, or any other manufacturer or supplier named on this page. Nihon Kohden, Life Scope, Vismo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Nihon Kohden JC-906PA Compatible ECG Trunk Cable?

The IPR Medical ET-6013-NKB-A is a compatible aftermarket (not OEM) 3/6-lead ECG trunk cable that replaces the Nihon Kohden JC-906PA. It is a reusable 8.2 ft (2.5 m) trunk cable with respiratory rate capability and AHA designation, intended for ECG monitoring with limb and chest leads. It is used with Nihon Kohden BR-9XXP leadwires.


Compatible Monitor Models

This trunk cable is listed for select Nihon Kohden BSM models such as the BSM-2351A, BSM-4114A, BSM-6501A, and BSM-9101, select Life Scope models including the Life Scope J and Life Scope TR, and select PVM and TEC models such as the PVM-2701 and TEC 8321. Several BSM entries are listed alongside YJ or AY part numbers; the table presents those configurations as listed. Please match your monitor against the Compatible Monitor Models table on the Specifications tab before ordering this trunk cable.


Design and Construction

The ET-6013-NKB-A supports 3-lead and 6-lead ECG configurations covering limb and chest placement, and it carries the AHA designation. The cable is 8.2 ft (2.5 m) long, includes a respiratory rate feature, and is used with Nihon Kohden BR-9XXP leadwires. It is reusable, so it can be cleaned between patients per facility protocol, and it is packaged one per bag.


When to Replace Your ECG Trunk Cable

Replace the trunk cable if the jacket is cracked, crushed, or kinked, if the leadwire connection points are loose or damaged, or if the monitor connector has bent pins or a cracked housing. ECG traces that drop out across every lead at once, noise that changes when the trunk cable is flexed, and unreliable respiration readings are typical signs of a failing trunk cable. Testing the same leadwires with a known-good trunk cable on the same monitor helps biomedical staff narrow down the fault.


Cross Reference and Interchange Part Numbers

This compatible trunk cable replaces the Nihon Kohden JC-906PA and also cross-references to Nihon Kohden K922A. All other interchange numbers are shown in the Cross Reference / Interchange Part Numbers table on the Specifications tab.


Why Source ECG Trunk Cables from IPR Medical?

Trunk cables are one of many monitor parts IPR Medical buys, sells, repairs, and stocks; as an ISO 9001:2015-certified independent service organization, we support both patient monitoring equipment and infusion pumps. With monitor repair and testing done in-house by our own technicians, we can help you match trunk cables and leadwires to your Nihon Kohden monitors and keep those monitors working. Our ECG cables and leadwires category has more options, and our team at 855-477-8866 can help with ordering, repairs, or parts.

IPR Medical buys, sells, repairs, and stocks parts for ECG trunk cables and the Nihon Kohden monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Nihon Kohden, or any other manufacturer or supplier named on this page. Nihon Kohden, Life Scope, Vismo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.