    GE CARESCAPE B450 Patient Monitor | Touchscreen, Transportable

    The GE CARESCAPE B450 is a 12-inch touchscreen multi-parameter patient monitor designed for flexible-acuity care areas including emergency departments, PACU, ICU, NICU, step-down units, and surgery centers. Built on the CARESCAPE monitoring platform, the B450 supports the CARESCAPE Patient Data Module (PDM), Patient Side Module (E-PSM/E-PSMP), and a single-width E-module slot, making it capable of continuous hemodynamic, respiratory, and neurophysiological monitoring at the bedside and during intra-hospital transport. Wireless and LAN connectivity, internal lithium-ion batteries, and care-area-specific software packages (OR, PACU, ICU, NICU, ED) make it one of the most versatile transportable monitors GE has produced on the Bx50 platform.

    Display
    12 in TFT LCD touchscreen, 1024 x 768 (XGA), 6 traces max

    Parameters Monitored
    ECG (3/5/6/10 lead), SpO2, NIBP, IBP, temperature, CO2, agents, BIS, Entropy, NMT, EEG, CCO, SvO2 (via PDM, E-PSM/E-PSMP, and E-modules)

    Patient Population
    Adult, pediatric, neonatal

    Battery / Portability
    1 or 2 exchangeable Li-Ion batteries, up to 3.5 hours runtime; integrated carrying handle, GCX and FM Quick-Mount compatible

    Connectivity
    CARESCAPE Network, S/5 Network, MUSE, Unity Network ID; LAN (3x RJ45), optional WLAN 802.11a/b/g

    Notable Features
    12SL diagnostic ECG, DINAMAP SuperSTAT NIBP, EK-Pro arrhythmia, optional in-built thermal recorder

    IPR Medical buys, sells, repairs, and stocks parts for the GE CARESCAPE B450. Contact us at 855-477-8866 or cs@iprmed.com.

  • Recertified
    Quick View

    GE CARESCAPE B650 Patient Monitor | 15″ Touchscreen, Modular

    The GE CARESCAPE B650 is a multi-parameter patient monitor intended for use in multiple areas and intrahospital transport within a professional healthcare facility. Built on the CARESCAPE platform, it combines a 15-inch touchscreen, a pivoting module frame, and compatibility with the Patient Data Module (PDM) and E-series plug-in modules for flexible clinical coverage across CCU, PACU, ED, NICU, and OR environments. The B650 supports EK-Pro arrhythmia analysis, 12SL ECG diagnostics, and integration with CARESCAPE Network-connected systems such as MUSE and CARESCAPE Central Station.

    Display
    15-inch color LCD touchscreen

    Parameters Monitored
    ECG, arrhythmia, ST, NIBP, SpO₂, IBP, temperature, respiration, CO₂, anesthetic agents, O₂, N₂O, and additional parameters via PDM/E-modules

    Patient Population
    Adult, pediatric, and neonatal

    Battery / Portability
    Optional internal lithium-ion battery supports intrahospital transport

    Connectivity
    CARESCAPE Network MC and IX; wired and wireless options; MUSE and Central Station integration

    Notable Features
    Pivoting module frame, PDM support, EK-Pro arrhythmia, 12SL diagnostic ECG, hardened Linux OS

    IPR Medical buys, sells, repairs, and stocks parts for the GE CARESCAPE B650 Patient Monitor. Contact us at 855-477-8866 or cs@iprmed.com.

  • -12%
    New
    Quick View

    Philips Avalon CL Wireless Ultrasound Transducer (866076)

    Original price was: $1,695.00.Current price is: $1,495.00.

    The Philips Avalon CL Wireless Ultrasound Transducer (866076) is the cableless fetal heart rate transducer in the Avalon CL Fetal Transducer System — a Smart Transducer with an onboard microprocessor that captures, processes, and digitally transmits the fetal heart rate signal directly to the Avalon fetal monitor. Its seven-crystal array (six crystals arranged around the perimeter with one in the center, in equilateral triangle geometry) delivers uniform acoustic coverage and strong cardiac detection with minimal repositioning, making it especially effective for twins, triplets, and active labor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same measurement performance as wired Smart Transducers at ranges up to 100 m (300 ft) line of sight.

    The 866076 supports Cross-Channel Verification (CCV) to prevent maternal-fetal heart rate confusion, Fetal Movement Profile (FMP) for high-risk pregnancy monitoring, and automatic channel assignment (FHR1/FHR2/FHR3) when multiple transducers are in use. It is watertight for underwater monitoring, weighs approximately 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic pairing and battery recharging.

    IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.

  • -7%
    Recertified
    Quick View

    Philips Avalon CL Wireless Transducer Base Station (866074)

    Original price was: $2,695.00.Current price is: $2,495.00.

    The Philips Avalon CL Wireless Transducer Base Station (866074) is the hub of the Philips Avalon CL cableless fetal monitoring system — the docking station, charger, and wireless gateway that transforms a wired Avalon fetal monitor into a fully cableless L&D solution. A single 866074 base station docks up to three cableless fetal transducers (866075 Toco+ MP, 866076 Ultrasound, and 866077 ECG/IUP) plus one maternal parameters slot for an IntelliVue CL Pod or range extension module, with a total assignment capacity of four CL transducers and two CL Pods. It connects to any Philips Avalon FM20, FM30, FM40, or FM50 fetal monitor via the fetal sensor socket — or to the rear telemetry connectors on the FM40 and FM50 — and delivers a line-of-sight operating range of up to 100 m (300 ft).

    Docked transducers and pods are assigned and recharged automatically, so labor teams can grab a patient-ready device and apply it with no setup. The 866074 base station is required for all Avalon CL transducers and pods. IPR Medical sells, buys, repairs, and stocks parts for the Philips Avalon CL system — including base stations, transducers, antennas, power supplies, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.

  • -39%
    New
    Quick View

    Veterinary IV Administration Set, 91 in., 20 Drop, 15 Micron Filter, DEHP-Free, SY0003

    Price range: $1.95 through $89.00

    This compatible veterinary IV administration set is a sterile, single-use infusion pump set designed for the delivery of medical solutions directly into a patient’s bloodstream via vein. The SY0003 features a vented spike with 5 micron hydrophobic air inlet filter, a drip chamber, 15 micron fluid filter, roller clamp, Y-injection site, rotating male Luer lock, and protective cap. Constructed from DEHP-free, latex-free PVC tubing measuring 91 inches in length, this set is lipid and alcohol resistant and individually packaged in a sealed pouch. The set is sterilized with Ethylene Oxide (ETO) and is intended for single patient use only, with replacement recommended at least every 24 hours.

    This set is compatible with all IPR Medical veterinary IV infusion pumps, including the Petite, Petite Heat, and Snippet. IPR Medical buys, sells, repairs, and stocks parts and disposables for veterinary infusion equipment. For availability or assistance, contact us at 855-477-8866 or cs@iprmed.com.

  • -23%
    New
    Quick View

    Veterinary Blood Administration IV Infusion Set, 67 in., 20 Drop, 15 Micron Filter, TS-V2

    Price range: $9.95 through $375.00

    This compatible veterinary blood administration IV infusion set is designed for use with veterinary infusion pumps in clinical and hospital settings. The TS-V2 features a vented spike with cap, an upstream drip chamber, a 15 micron inline filter for blood and fluid transfusions, and PVC tubing spanning 67 inches. An injection site, roller clamp, male Luer lock, and protector cap are included for a complete, ready-to-use setup. The set is sterilized with Ethylene Oxide (ETO) and is intended for single use only, with replacement recommended at least every 24 hours.

    This set is compatible with all IPR Medical veterinary IV infusion pumps, including the Petite, Petite Heat, and Snippet. IPR Medical buys, sells, repairs, and stocks parts and disposables for veterinary infusion equipment. For availability or assistance, contact us at 855-477-8866 or cs@iprmed.com.

  • -23%
    RecertifiedQuick View

    Philips IntelliVue M3012A Hemodynamic Extension | Option C00, Dual Pressure & Dual Temperature

    Original price was: $1,295.00.Current price is: $995.00.

    The Philips IntelliVue M3012A (Option C00) is the base configuration of the IntelliVue Hemodynamic Measurement Server Extension. It attaches directly to the Philips M3001A Multi-Measurement Module to add two independent invasive pressure channels, two independent temperature channels, and one combined pressure/temperature connector — enabling simultaneous hemodynamic pressure and temperature monitoring that the M3001A’s single shared C06 or C18 connector cannot provide on its own. The M3012A C00 is the standard hemodynamic expansion unit for ICU, cardiovascular step-down, and critical care transport environments where multiple pressure lines, bilateral temperature monitoring, or both are required alongside the M3001A’s core vital signs parameter set, but cardiac output measurement is not part of the clinical protocol.

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3012A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -10%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A04C18, 12-Lead ECG, Nellcor OxiMax SpO2, IBP & Temp

    Original price was: $1,995.00.Current price is: $1,795.00.

    The Philips IntelliVue M3001A (Option A04C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module for facilities using Nellcor OxiMax sensors on the newer Hardware Revision C platform. The C18 option combines both extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG using 5 electrodes, QT/QTc monitoring, respiration, Nellcor OxiMax-compatible SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration. The A04C18 is the Hardware Revision C equivalent of the A02C18: clinically identical in every measurement capability with OxiMax sensors connecting through the M1943NL adapter cable, built on the newer internal platform identified by serial number prefixes DE610, DE632, DE717, and DE907. As with all M3001A C18 configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.

    Part Number / Option
    M3001A, Option A04C18

    Parameters Monitored
    ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)

    SpO2 Technology
    Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connection

    Hardware Generation
    Revision C — serial number prefixes DE610, DE632, DE717, DE907; newer platform vs. A02C18

    12-Lead ECG
    Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supported

    IBP / Temp Port
    One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this port

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -10%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A04C12, 12-Lead ECG & Nellcor OxiMax SpO2

    Original price was: $1,995.00.Current price is: $1,795.00.

    The Philips IntelliVue M3001A (Option A04C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module for facilities using Nellcor OxiMax sensors on the newer Hardware Revision C platform. Building on the A04 standard package — ECG, arrhythmia, ST, respiration, Nellcor OxiMax-compatible SpO2, and oscillometric NBP — the C12 option adds conventional 12-lead ECG capture and EASI-derived 12-lead ECG using only 5 electrodes. The A04C12 is the Hardware Revision C equivalent of the A02C12: clinically identical in 12-lead ECG capability and OxiMax sensor interface, built on the newer internal platform identified by serial number prefixes DE610, DE632, DE717, and DE907. OxiMax sensors connect through the M1943NL adapter cable as with all A02 and A04 configurations. The A04C12 is the correct choice for facilities requiring documented 12-lead ECG alongside continuous monitoring in a Nellcor OxiMax environment, without invasive pressure or temperature in the MMS module.

    Part Number / Option
    M3001A, Option A04C12

    Parameters Monitored
    ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric)

    SpO2 Technology
    Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connection

    Hardware Generation
    Revision C — serial number prefixes DE610, DE632, DE717, DE907; newer platform vs. A02C12

    12-Lead ECG
    Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supported

    Invasive Pressure / Temperature
    Not included in Option A04C12 — available with Option A04C18

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -13%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A03C18, 12-Lead ECG, Masimo SET SpO2, IBP & Temp

    Original price was: $1,595.00.Current price is: $1,395.00.

    The Philips IntelliVue M3001A (Option A03C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. The C18 option combines both extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG using 5 electrodes, QT/QTc monitoring, respiration, Masimo SET SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration with Masimo LNCS sensor compatibility. The A03C18 is the direct Masimo SET equivalent of the A01C18 and A02C18: clinically identical in every measurement capability, with Masimo LNCS sensors connecting via the Masimo LNC MP-10 dual-key patient cable (part 2281). As with all M3001A C18 configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.

    Part Number / Option
    M3001A, Option A03C18

    Parameters Monitored
    ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Masimo SET SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)

    SpO2 Technology
    Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection

    12-Lead ECG
    Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supported

    IBP / Temp Port
    One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this port

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -13%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A03C12, 12-Lead ECG & Masimo SET SpO2

    Original price was: $1,595.00.Current price is: $1,395.00.

    The Philips IntelliVue M3001A (Option A03C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. Building on the A03 standard package — ECG, arrhythmia, ST, respiration, Masimo SET SpO2, and oscillometric NBP — the C12 option adds conventional 12-lead ECG capture and EASI-derived 12-lead ECG using only 5 electrodes. The A03C12 is the Masimo SET equivalent of the A01C12 and A02C12: clinically identical in 12-lead ECG capability and overall parameter set, with the SpO2 interface built around a dedicated Masimo SET circuit, and Masimo LNCS sensors connecting via the Masimo LNC MP-10 dual-key patient cable (part 2281). It is the correct choice for facilities that require documented, diagnostic-quality 12-lead ECG recordings alongside continuous monitoring and are standardized on Masimo LNCS sensors, but do not need invasive pressure or temperature within the MMS module itself.

    Part Number / Option
    M3001A, Option A03C12

    Parameters Monitored
    ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Masimo SET SpO2, NBP (oscillometric)

    SpO2 Technology
    Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection

    12-Lead ECG
    Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supported

    Invasive Pressure / Temperature
    Not included in Option A03C12 — available with Option A03C18

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

  • -9%
    Recertified
    Quick View

    Philips IntelliVue M3001A Multi-Measurement Module | Option A02C18, 12-Lead ECG, Nellcor OxiMax SpO2, IBP & Temp

    Original price was: $1,095.00.Current price is: $995.00.

    The Philips IntelliVue M3001A (Option A02C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Nellcor OxiMax sensors. The C18 option combines both extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG using 5 electrodes, QT/QTc monitoring, respiration, Nellcor OxiMax-compatible SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration with OxiMax sensor compatibility. The A02C18 is the direct Nellcor OxiMax equivalent of the A01C18: clinically identical in every measurement capability, with OxiMax sensors connecting through the M1943NL adapter cable. As with all M3001A C-option configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.

    Part Number / Option
    M3001A, Option A02C18

    Parameters Monitored
    ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)

    SpO2 Technology
    Nellcor OxiMax-compatible — requires M1943NL adapter cable for OxiMax sensor connection

    12-Lead ECG
    Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supported

    IBP / Temp Port
    One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this port

    Host Monitor Compatibility
    IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)

    Data Storage
    Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

    IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.