Philips CL Wireless ECG / IUP Transducer (866077)
$1,195.00The Philips Avalon CL Wireless ECG/IUP Transducer (866077) is a cableless, battery-powered transducer that captures maternal ECG, fetal ECG (DECG), and intrauterine pressure (IUP) on a single device — giving labor and delivery teams three internal and maternal measurements without tethering the patient to the monitor. Paired with the Avalon CL Base Station (866074) and Avalon FM20, FM30, FM40, or FM50 fetal monitors, it delivers the same measurement performance as wired Smart Transducers while letting mothers walk, shower, or reposition during labor with an operating range of up to 100 m (300 ft) line of sight.
The 866077 is watertight for underwater monitoring, weighs only 0.6 lbs (0.27 kg), and docks directly into the Avalon CL base station for automatic assignment and battery recharging — no patient cables, no separate charger. IPR Medical sells, buys, repairs, and stocks parts and accessories for the Philips Avalon CL system, including transducers, base stations, belts, and replacement batteries. Contact us at 855-477-8866 or cs@iprmed.com.
-
Stryker/Gaymar T/Pump TP700
Original price was: $1,395.00.$1,195.00Current price is: $1,195.00.The Stryker/Gaymar T/Pump® TP700 is a professional-grade localized temperature therapy system that circulates temperature-controlled water through a Stryker Mul•T•Pad® to deliver precise warming or cooling therapy to targeted body areas. Four selectable setpoints — 50°F (cooling), 95°F, 100°F, and 107°F — cover everything from post-operative hypothermia prevention and edema management to chronic joint pain and muscle strain relief. The TP700 upgrades over the classic TP600 with a fourth warming setpoint (95°F), programmable therapy cycles (20-minute, 30-minute, or continuous), and a setpoint lockout feature that prevents accidental temperature changes mid-treatment. A three-layer safety architecture — dual temperature sensors, dual microprocessors, and a mechanical over-temperature thermostat — ensures the pad never exceeds the 107°F maximum contact surface temperature. At 6.5 lbs empty and with built-in hose and cord management, the TP700 is easy to position at bedside, in recovery, or in the OR.
IPR Medical buys, sells, and repairs the Stryker/Gaymar T/Pump TP700 and stocks compatible Mul•T•Pad® accessories and replacement parts. Contact us at 855-477-8866 or cs@iprmed.com.
-
B Braun Vista Basic
$1,295.00The B. Braun Vista Basic is a linear peristaltic volumetric infusion pump built around a single principle: simplicity without compromise. Designed for ease of use across acute care, outpatient, and home infusion settings, the Vista Basic delivers accurate, continuous and programmable infusions of parenteral and enteral fluids across a rate range of 0.1 to 800.0 ml/h with Vista tubing — or up to 999.9 ml/h with Intrafix sets — in 0.1 ml/h increments. Flow accuracy is rated at ±5%.
The aluminum housing is drip-proof, resistant to disinfectants, and built for the day-to-day demands of clinical use. Straight-line tubing loads quickly without the need to thread complex pathways, and the plain-language LCD display walks operators through programming step by step. The 7.2V NiCd rechargeable battery provides approximately 3.5 hours of runtime at maximum delivery rate. A drop sensor detects upstream occlusions and empty containers, and a data lock feature prevents unauthorized reprogramming during active infusions.
With over 100,000 units in service worldwide, the Vista Basic has earned its reputation as a dependable workhorse — equally at home on a hospital floor, in an infusion clinic, or in a home care setting. IPR Medical buys, sells, and repairs the B. Braun Vista Basic and stocks replacement parts. Contact us at 855-477-8866 or cs@iprmed.com.
Looking for a more modern alternative? The B. Braun Infusomat Space Version U is B. Braun’s current-generation large volume pump platform, featuring an integrated drug library, modular Space system stacking, wireless drug library upload, and upstream and downstream pressure sensing — a natural upgrade path for facilities already familiar with B. Braun infusion equipment.
-
Sigma Spectrum Version 8
Original price was: $1,495.00.$1,295.00Current price is: $1,295.00.The Baxter SIGMA Spectrum Infusion Pump Version 8 is one of the most trusted large-volume infusion pumps in North American acute care — and for good reason. It combines a wide flow rate range (0.5 to 999 ml/h), a customizable Master Drug Library with up to 32 Care Areas, and configurable Dose Error Reduction Software (DERS) that guides clinicians through safe programming from the moment they power the pump on. A human factors study put the task success rate at 99.1% across all user groups — which is a fancy way of saying it’s genuinely intuitive to use, even under busy clinical conditions.
What makes the Spectrum V8 a smart choice for facilities isn’t just the feature list — it’s the ecosystem. The pump runs on Baxter’s standard CONTINU-FLO IV sets, which work for both gravity and pump infusions, cutting down on setup time and set waste. And because IPR Medical stocks compatible Baxter IV administration sets, you can source pumps and consumables from one place.
Also available:
- Baxter Sigma Spectrum Version 6 — earlier Spectrum platform for facilities that don’t require full EMR integration
- Baxter Spectrum IQ — full EMR integration with Auto-Programming, Auto-Documentation, and built-in asset tracking
IPR Medical buys, sells, repairs, and stocks parts for the Baxter SIGMA Spectrum Version 8. Whether you need a refurbished unit, a replacement part, or fleet service, we’ve got you covered. Call us at 855-477-8866 or reach out at cs@iprmed.com.
-
Philips IntelliVue X2 Multi-Measurement Module
$1,295.00The Philips IntelliVue X2 (M3002A) is a combined Multi-Measurement Module and portable transport monitor designed for use across the hospital continuum — from the ICU and OR to intra-hospital transport and intermediate care. In standalone mode it operates on a rechargeable battery and monitors ECG, arrhythmia, ST, respiration, SpO2, NBP, and optional invasive pressure, temperature, and CO2; when docked to a host IntelliVue monitor it seamlessly hands off all measurements, trends, and patient data as an MMS. The X2’s 3.5-inch touchscreen and configurable SmartKeys give clinicians immediate access to parameters and alarm controls without interrupting patient monitoring.
Display
3.5-inch TFT LCD touchscreen, QVGAParameters Monitored
ECG (3/5/6/10-lead), Arrhythmia, ST, QT/QTc, Respiration, SpO2, NBP, Temp (opt.), IBP (opt.), CO2 (opt.)Patient Population
Adult, Pediatric, NeonatalBattery / Portability
Rechargeable M4607A battery; up to ~3 hrs standalone; up to ~6 hrs with Battery ExtensionDevice Weight
1.98–2.64 lbs (depending on options)Connectivity
Wired LAN, built-in WLAN, Short Range Radio (SRR), MSL connectorHost Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90 (MMS mode)IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue X2. Contact us at 855-477-8866 or cs@iprmed.com.
-
Baxter Auto Syringe AS50 Infusion Pump
Original price was: $1,995.00.$1,395.00Current price is: $1,395.00.The Baxter Auto Syringe AS50 is a compact, single-channel syringe infusion pump designed for accurate continuous or intermittent delivery of intravenous solutions, drug solutions, whole blood, and packed red blood cells. It supports IV, intra-arterial, epidural, and subcutaneous routes, accepts standard disposable syringes from 1 mL to 60 mL across three manufacturers, and operates on internal rechargeable battery or AC charger for bedside, transport, and ambulatory use.
Pump Type
Single-channel syringe infusion pumpFlow Rate Range
0.01 to 438 mL/hr (syringe-dependent)Compatible Syringes
B-D Plastic, Sherwood Monoject, and Terumo, 1–60 mLDrug Library
Configurable Protocol Library; 18 infusion modesConnectivity
DB-9 RS-232 serial port (remote monitoring/control)Battery
Internal rechargeable pack; 5 hr at 100 mL/hr or 12 hr at 2 mL/hrNotable Features
Bolus, titration, syringe recognition, keypad lock, backlightIPR Medical buys, sells, repairs, and stocks parts for the Baxter Auto Syringe AS50 Infusion Pump. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips M2734A / M2734B Smart Toco MP Transducer | Avalon
$1,395.00The Philips M2734A and M2734B are wired Smart Toco MP transducers used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50). They combine two parameters in a single sensor — external uterine activity (Toco) and maternal pulse (MP) — and enable the Avalon platform’s Smart Pulse automated coincidence detection, which cross-checks the maternal pulse against the fetal heart rate to confirm the host monitor is not inadvertently tracking maternal heart rate as fetal. The M2734B is the successor revision to the M2734A and is functionally interchangeable on the Avalon Toco socket; both are auto-identifying via the Smart-interface (pink) connector and carry internal calibration data storage.
Device Type
Wired dual-parameter Smart Toco MP transducer (uterine activity + maternal pulse)Models
M2734A (original Smart Toco MP) and M2734B (successor revision); both share the same role and Avalon socketCompatible Monitors
Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) at supported software revisionsConnector
Wired Smart-interface (pink) connector to the dedicated Toco socket on the Avalon host monitorKey Features
Dual-parameter Toco + maternal pulse, Smart Pulse coincidence detection, waterproof housing for shower/bath use, latex-free, auto-identification, internal calibration data storagePatient Population
Antepartum testing and labor and deliveryIPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon fetal monitor family, including the M2734A and M2734B Smart Toco MP transducers. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips Compatible Wireless Toco Transducer for Philips Avalon | M2725A
$1,395.00This is an aftermarket-compatible cordless Toco transducer designed to function as a direct replacement for the M2725A wireless Toco fetal transducer used with the Philips Avalon family of fetal/maternal monitors (FM20, FM30, FM40, FM50) when paired with the Avalon CTS cordless transducer base station (M2720A). It uses a strain-gauge pressure sensor to detect uterine activity by evaluating the hardness of the maternal abdomen during labor, transmitting the signal wirelessly to the CTS base so the patient retains freedom of movement during antepartum testing and labor and delivery. This is a compatible aftermarket part — not a Philips-manufactured product — sold and supported by IPR Medical.
Device Type
Aftermarket-compatible cordless (wireless) external Toco transducer for fetal/maternal monitoringReplaces / Cross Reference
M2725A cordless Toco transducer (also referenced as part 862488)Compatible Monitors
Philips Avalon FM20 (M2702A), FM30 (M2703A), FM40 (M2704A), FM50 (M2705A) — used together with the Avalon CTS base station (M2720A)Patient Population
Antepartum testing and labor and delivery; ambulatory patients within the CTS base station’s coverage areaKey Features
Cordless operation, lightweight handheld form factor, waterproof housing for shower/bath use during labor, on-board status indicatorsMounting
Snap-clip belt fixing onto compatible reusable or waterproof fetal monitoring beltsIPR Medical buys, sells, repairs, and stocks parts for the Philips Avalon Cordless Transducer System (CTS), including aftermarket-compatible wireless Toco transducers for the M2725A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A03C06, Masimo SET SpO2, IBP & Temp
Original price was: $1,595.00.$1,395.00Current price is: $1,395.00.The Philips IntelliVue M3001A (Option A03C06) is the extended-measurement configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. Building on the A03 standard package — ECG, arrhythmia, ST, respiration, Masimo SET SpO2, and oscillometric NBP — the C06 option adds a combined invasive pressure and temperature connector, enabling the module to support either invasive blood pressure monitoring or temperature measurement in addition to the full core parameter set. The A03C06 is the Masimo SET equivalent of the A01C06 and A02C06, delivering an identical clinical measurement footprint while using a dedicated Masimo SET SpO2 interface and requiring the Masimo LNC MP-10 dual-key patient cable for sensor connection. This configuration is widely deployed in ICU, cardiovascular step-down, post-anesthesia care, and critical care transport environments where arterial line monitoring or core temperature tracking is standard practice alongside a Masimo LNCS sensor fleet. As with all M3001A variants, patient demographics, trend data, and measurement settings are stored in the module itself and travel with the patient between IntelliVue host monitors.
Part Number / Option
M3001A, Option A03C06Parameters Monitored
ECG (3/5-lead), Arrhythmia, ST, Respiration, Masimo SET SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)SpO2 Technology
Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connectionIBP / Temp Port
One combined connector — supports invasive pressure transducer OR temperature probe; pressure and temperature cannot be used simultaneously on this portHost Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A03C12, 12-Lead ECG & Masimo SET SpO2
Original price was: $1,595.00.$1,395.00Current price is: $1,395.00.The Philips IntelliVue M3001A (Option A03C12) is the 12-lead ECG configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. Building on the A03 standard package — ECG, arrhythmia, ST, respiration, Masimo SET SpO2, and oscillometric NBP — the C12 option adds conventional 12-lead ECG capture and EASI-derived 12-lead ECG using only 5 electrodes. The A03C12 is the Masimo SET equivalent of the A01C12 and A02C12: clinically identical in 12-lead ECG capability and overall parameter set, with the SpO2 interface built around a dedicated Masimo SET circuit, and Masimo LNCS sensors connecting via the Masimo LNC MP-10 dual-key patient cable (part 2281). It is the correct choice for facilities that require documented, diagnostic-quality 12-lead ECG recordings alongside continuous monitoring and are standardized on Masimo LNCS sensors, but do not need invasive pressure or temperature within the MMS module itself.
Part Number / Option
M3001A, Option A03C12Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Masimo SET SpO2, NBP (oscillometric)SpO2 Technology
Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection12-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedInvasive Pressure / Temperature
Not included in Option A03C12 — available with Option A03C18Host Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips IntelliVue M3001A Multi-Measurement Module | Option A03C18, 12-Lead ECG, Masimo SET SpO2, IBP & Temp
Original price was: $1,595.00.$1,395.00Current price is: $1,395.00.The Philips IntelliVue M3001A (Option A03C18) is the fully loaded single-module configuration of the IntelliVue Multi-Measurement Module for facilities standardized on Masimo LNCS sensors. The C18 option combines both extended measurement packages into one: the 12-lead ECG capability of the C12 option and the invasive pressure/temperature channel of the C06 option. The result is a module that delivers 3-, 5-, and 12-lead ECG with arrhythmia and ST monitoring, EASI-derived ECG using 5 electrodes, QT/QTc monitoring, respiration, Masimo SET SpO2, oscillometric NBP, and either invasive blood pressure or temperature — the broadest parameter set available in a single M3001A configuration with Masimo LNCS sensor compatibility. The A03C18 is the direct Masimo SET equivalent of the A01C18 and A02C18: clinically identical in every measurement capability, with Masimo LNCS sensors connecting via the Masimo LNC MP-10 dual-key patient cable (part 2281). As with all M3001A C18 configurations, invasive pressure and temperature share a single connector and cannot be used simultaneously without an MMS extension.
Part Number / Option
M3001A, Option A03C18Parameters Monitored
ECG (3/5/12-lead), EASI ECG, Arrhythmia, ST (up to 12-lead), QT/QTc, Respiration, Masimo SET SpO2, NBP (oscillometric), Invasive Pressure OR Temperature (shared port — not simultaneous)SpO2 Technology
Masimo SET — requires Masimo LNC MP-10 dual-key patient cable (part 2281) for LNCS sensor connection12-Lead ECG
Yes — conventional 12-lead capture with diagnostic signal quality (ANSI/AAMI EC11); EASI 12-lead using 5 electrodes also supportedIBP / Temp Port
One combined connector — supports invasive pressure transducer OR temperature probe; cannot be used simultaneously on this portHost Monitor Compatibility
IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)Data Storage
Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnectedIPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.
-
Philips Avalon Ultrasound Fetal Transducer
$1,475.00The Philips Avalon Ultrasound Fetal Transducer is a state-of-the-art device designed to deliver precise and continuous monitoring of fetal heart rate and activity. This advanced transducer leverages cutting-edge ultrasound technology to ensure accurate and reliable data, which is crucial for making informed clinical decisions during labor and delivery. Its ergonomic design and lightweight construction ensure patient comfort and ease of use for healthcare providers. The Philips Avalon Ultrasound Fetal Transducer integrates seamlessly with existing Philips fetal monitoring systems, providing a cohesive and efficient workflow in maternity wards. The device features a durable, high-quality build, ensuring consistent performance even in the most demanding clinical settings. Real-time, clear displays and alerts keep healthcare providers informed of any changes in fetal status, allowing for timely interventions. The transducer’s intuitive interface simplifies setup and operation, reducing training time and enhancing overall efficiency. Invest in the Philips Avalon Ultrasound Fetal Transducer for unparalleled accuracy, reliability, and comfort in fetal monitoring.
Brand new units may be available. Please contact us directly for more information.