B. Braun Infusomat Space Volumetric Infusion Pump (Version U) – Recertified
The B. Braun Infusomat® Space® Version U (software 586U) is a volumetric large-volume infusion pump designed for critical care, ICU, CCU, NICU, PICU, OR, and emergency settings in adult, pediatric, and neonatal patients. Delivering 0.1 to 1,200 ml/h at ±5% accuracy with a linear peristaltic pumping mechanism, the Infusomat Space Version U offers a comprehensive therapy profile set including Primary and Secondary (piggyback) infusions, Dose Over Time, Ramp and Taper, Program Mode, Intermittent, PCA, Loading Dose, and wireless AutoProgramming with EHR integration.
Part of the B. Braun Space System, up to three pumps stack on a single pole clamp with a universal interface shared with the Perfusor Space — reducing staff training requirements across the fleet. Dual occlusion sensing monitors both upstream and downstream pressure independently. The pump integrates into SpaceStation for wireless drug library upload, EHR autoprogramming, and fleet management. WiFi requires the B. Braun WiFi battery module, available separately — all standard sales include a non-WiFi Li-Ion battery.
Brand new units are available. Please contact us directly for more information.
IPR Medical buys, sells, repairs, and stocks parts for the B. Braun Infusomat Space.
Rx only. Sold to healthcare facilities, licensed practitioners and equipment service providers; not sold to patients for home use (Terms §8).
Warranty: IPR Medical limited warranty, 6 months unless a longer period is stated on this page or your invoice; extended warranties available (Terms §5).
B. Braun Infusomat® Space® Volumetric Infusion Pump — Version U (Software 586U)
Large-volume volumetric infusion pump for critical care, ICU, NICU, PICU, OR, and emergency settings. 0.1–1,200 ml/h at ± 5% accuracy with linear peristaltic mechanism. Dual upstream and downstream occlusion sensing, set and pump-based anti-free flow protection, primary and secondary (piggyback) infusion, wireless AutoProgramming, and EHR integration. Part of the B. Braun Space System. IPR Medical buys, sells, repairs, and stocks parts for the Infusomat Space Version U.
| Manufacturer | B. Braun Melsungen AG |
| Software Version | 586U (US) |
| Pump Type | Volumetric large-volume infusion pump; linear peristaltic mechanism |
| Intended Use | Intermittent or continuous delivery of parenteral fluids, medications, blood and blood products, TPN, lipids, and enteral fluids; adults, pediatrics, and neonates; intravenous, intra-arterial, subcutaneous, epidural, and enteral routes; healthcare facilities and medical transport environments |
| Flow Rate Range | 0.1 – 1,200 ml/h |
| Accuracy | ± 5% per IEC/EN 60601-2 – 24; maintained for a minimum of 96 hours per administration set change interval |
| Bolus Rate | 1 – 1,200 ml/h; manual and programmable modes |
| VTBI | 0.1 – 9,999 ml |
| Time Selection | 00:01 – 99:59 hours |
| KVO Rate | Configurable; automatically activates at end of program |
| Therapy Profiles | Primary infusion, Secondary (piggyback) infusion, Dose Rate Calculation, Dose Over Time, Loading Dose, Ramp and Taper Mode, Program Mode, Intermittent Mode, Bolus with Dose and Time, Manual Bolus, PCA (optional), KVO |
| Secondary / Piggyback | Dedicated secondary infusion programming with automatic return to primary rate on completion |
| Occlusion Sensing | Dual independent sensors — downstream occlusion (9 selectable pressure levels) and upstream occlusion; both alarm independently |
| Anti-Free Flow Protection | Dual protection: set-based anti-free flow clip and pump-based safety clamp — both engage automatically when the pump door is opened |
| Air Detection | Ultrasonic air-in-line sensor; single bubble and cumulative air detection; configurable thresholds |
| Max Single Fault Volume | 1.4 ml — pump automatically shuts off upon detection |
| Drug Library | Up to 1,500 drug names with therapy data stored in 30 categories; up to 50 care units and 15 patient profiles; drug-specific hard and soft limits, default values, and clinical advisories; DoseGuard software powered by FDB Infusion Knowledge |
| Wireless Drug Library Upload | Via SpaceStation — wireless fleet-wide drug library updates without physically handling each pump (requires WiFi battery, sold separately) |
| AutoProgramming | Accepts drug orders wirelessly from EHR system or from SpaceStation with SpaceCom; pre-populates drug name, concentration, and dose for clinician confirmation before infusion starts |
| Connectivity | Wireless (requires WiFi battery module, sold separately) and wired; SpaceStation integration for drug library updates, EHR autoprogramming, staff call, and fleet management; USB via B. Braun CAN SP interface lead |
| History Log | Up to 3,000 history entries |
| MR Conditional | Yes — when used within SpaceStation MRI; unsafe as standalone device in MRI proximity |
| Classification | Type CF, defibrillation-proof; Class II (standalone); Class I in combination with SpaceStation; Class IIb per EU Directive 93/42/EEC |
| Water Resistance | IP22 (drip-protected for horizontal usage) |
| Power — AC | 100–240V AC, 50/60 Hz (via SpaceStation or optional mains adapter) |
| Power — DC | 11–16V DC via Connection Lead SP 12V or SpaceStation |
| Battery — Standard (included) | Li-Ion battery included with all sales; approx. 5 hours runtime at 1,200 ml/h; longer runtime at lower rates; recharge time approx. 6 hours. Does not support WiFi connectivity. |
| Battery — WiFi (sold separately) | WiFi functionality requires the B. Braun Battery Pack SP with WiFi — not included with standard sales, available for separate purchase through IPR Medical. Enables wireless drug library uploads, EHR AutoProgramming, and SpaceStation connectivity. |
| Stacking | Up to 3 Space pumps (Infusomat or Perfusor) per pole clamp; SpaceStation docking stations combine more pumps in one bedside tower |
| Operating Environment | Temperature: 41 – 104°F; Humidity: 30–90% non-condensing; Pressure: 500–1,060 mbar |
| Storage / Transport | Temperature: – 4 – 131°F; Humidity: 20–90% non-condensing; Pressure: 500–1,060 mbar |
| Dimensions | 8.4″ L × 4.9″ W × 2.6″ D |
| Weight | Approx. 3 lbs (1.4 kg) |
| Standards | IEC 60601-1:2005; IEC 60601-2-24:2012; IEC 60601-1-2:2007; ISO 9001 |
IPR Medical buys, sells, repairs, and stocks parts for the B. Braun Infusomat Space Version U. WiFi battery modules available separately. Contact us for unit availability, parts inventory, repair turnaround, and pricing at 855-477-8866 or cs@iprmed.com.
Trademark Notice: B. Braun, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by B. Braun.
Quick answer: The B. Braun Infusomat Space Version U (software 586U) is a large-volume infusion pump delivering 0.1 to 1,200 ml/h with dual upstream and downstream occlusion sensing and AutoProgramming support. IPR Medical sells recertified units backed by IPR Medical’s warranty, plus brand new units, repairs the pump in-house, and stocks parts and WiFi battery modules.
The Space System large-volume pump — same interface, deeper therapy support
The B. Braun Infusomat® Space® Version U is the large-volume counterpart to the Perfusor Space in the B. Braun Space System — sharing the same form factor, pole clamp, universal user interface, and Space System integration, while delivering the volumetric infusion capabilities that syringe pumps cannot match. At 0.1 to 1,200 ml/h with ±5% accuracy, dual upstream and downstream occlusion sensing, dual anti-free flow protection, and a full therapy profile set including primary, secondary (piggyback), TPN, intermittent, and PCA modes, the Infusomat Space Version U is built for the full clinical range from low-rate critical care infusions to high-rate resuscitation and nutritional therapy.
Dual occlusion sensing — upstream and downstream independently
Unlike most large-volume pumps that only monitor downstream pressure, the Infusomat Space monitors both upstream (between the bag and the pump) and downstream (between the pump and the patient) pressure independently. The downstream occlusion pressure is user-selectable across nine levels. The upstream sensor detects closed roller clamps, empty bags, and kinked lines above the pump before they affect delivery — providing an earlier warning upstream that downstream-only sensors cannot catch. Both channels alarm independently with clear on-screen identification of which side has triggered.
Dual anti-free flow protection
The Infusomat Space provides two independent anti-free flow mechanisms. The set-based anti-free flow clip is built into the dedicated B. Braun administration set and clamps automatically when removed from the pump. The pump-based safety clamp engages when the pump door is opened, preventing uncontrolled flow from gravity during line changes. Both engage simultaneously on door open — providing redundant protection against inadvertent free flow during IV set changes, a critical safety feature in ICU, OR, and NICU environments.
Primary and secondary (piggyback) infusion
Version U supports dedicated secondary infusion programming — allowing a piggyback medication to be programmed and infused at a separate rate and VTBI, with the pump automatically returning to the primary infusion rate on completion. This eliminates the need for manual rate adjustment during piggyback delivery and reduces the risk of the clinician forgetting to return to the primary rate after the secondary bag is finished.
AutoProgramming, wireless drug library, and EHR integration
Version U supports AutoProgramming — the pump receives drug orders wirelessly from the EHR or from SpaceStation with SpaceCom, pre-populating drug name, concentration, and dose for clinician confirmation before the infusion starts. Wireless drug library uploads via SpaceStation allow pharmacy to push library updates fleet-wide without physically handling each pump. Note that wireless functionality requires the B. Braun WiFi battery module, available separately — all standard unit sales include a non-WiFi Li-Ion battery.
WiFi battery — available separately
All Infusomat Space Version U units sold by IPR Medical include a standard non-WiFi Li-Ion battery. To enable wireless connectivity — including wireless drug library uploads, EHR AutoProgramming, and SpaceStation communication — the B. Braun Battery Pack SP with WiFi is required and must be purchased separately. Contact IPR Medical to add a WiFi battery module to your order.
B. Braun Space System integration
The Infusomat Space shares the B. Braun Space System platform with the Perfusor Space syringe pump. Up to three pumps stack and interlock on a single pole clamp. Through SpaceStation docking stations, multiple pumps can be organized in a single bedside tower — combining Infusomat and Perfusor Space units with a shared interface, shared drug library management, and shared EHR connectivity. The universal keypad and menu navigation across all Space pumps substantially reduces staff training time compared to managing multiple different pump platforms.
IPR Medical — sales, repairs, and parts for the Infusomat Space Version U
IPR Medical buys, sells, repairs, and stocks replacement parts for the B. Braun Infusomat Space Version U. Whether you need a patient-ready refurbished unit, a WiFi battery module, a specific replacement component, or repair service on pumps already in your fleet, our biomedical technicians are ready to help.
IPR Medical buys, sells, repairs, and stocks parts for the B. Braun Infusomat Space Version U. WiFi battery modules available separately. Contact us for unit availability, parts inventory, repair turnaround, and pricing at 855-477-8866 or cs@iprmed.com.
Also available: Infusomat Space Version G. Call (855) 477-8866 if you are not sure which software version matches your facility’s Space system.
Frequently asked questions
Does the Infusomat Space Version U include WiFi?
Not by default. All Version U units sold by IPR Medical include a standard non-WiFi Li-Ion battery. Wireless drug library uploads, EHR AutoProgramming, and SpaceStation communication require the B. Braun Battery Pack SP with WiFi, which is purchased separately. Contact IPR Medical to add a WiFi battery module to your order.
Does the Infusomat Space Version U work with the Perfusor Space?
Yes. The Infusomat Space shares the B. Braun Space System platform with the Perfusor Space syringe pump. Up to three pumps stack on one pole clamp, and SpaceStation docking stations combine more pumps in one bedside tower with a shared interface, which reduces staff training across the fleet.
Can IPR Medical load our drug library on Version U pumps?
Please contact our team about drug library questions for the Infusomat Space Version U, including SpaceStation and wireless library uploads. Reach IPR Medical at (855) 477-8866 or cs@iprmed.com, Monday through Friday, 7:00 AM to 4:30 PM Pacific, to discuss your facility’s setup.
Does IPR Medical repair the Infusomat Space Version U?
Yes. Our in-house technicians repair Infusomat Space pumps. U.S. customers can request a free inbound shipping label through our RMA form, and we provide a free evaluation and a written estimate, with no charge until approval. Repaired pumps are tested to OEM specifications, cleaned, and covered by a 90-day warranty.
Repair service: IPR Medical also repairs B. Braun pumps in house, with a free shipping label, a free evaluation and a 90-day repair warranty. See B. Braun pump repair.
Trademark Notice: B. Braun, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by B. Braun.
Buying a recertified B. Braun Infusomat Space (Version U) from IPR Medical
Every B. Braun Infusomat Space (Version U) sold by IPR Medical is a recertified unit that is inspected and tested by our team before it ships. Orders have a handling time of 1–2 business days, with $25 flat-rate shipping within the US (Alaska and Hawaii $80). Returns are accepted within 30 days, returned by mail, subject to a 25% restocking fee; see our returns policy for details.
Not sure this is the right model or version for your facility? Contact IPR Medical before you order and we will confirm compatibility and availability. You may also want to look at: Infusomat Space Version G.
Infusomat Space Guides from IPR Medical
- Infusomat Space Repair: The Most Common Problems – what our technicians find most often, what causes it, and how to prevent it.
- Infusomat Space Recalls and Software Versions – FDA recalls and corrections in plain English, Version F, G and U, and a biomed checklist.
- Infusomat Space Manuals and Documentation – instructions for use, compatible IV sets and key specifications.
| Weight | 4 lbs |
|---|---|
| Dimensions | 12 × 12 × 12 in |
| Product Condition | Brand New, Recertified |
- Pole Clamp (New or Used)
- AC Adapter (New or Used)
- NiMH Non-Wireless and Wireless Battery:
Reviews
There are no reviews yet.