Datex-Ohmeda / GE Compatible Adult Finger Clip SpO2 Sensor, Hard Shell, 10 ft (3.0 m) – OXY-F4-N
The Datex-Ohmeda / GE Healthcare OXY-F4-N compatible adult finger clip SpO2 sensor (SKU SS-014-AF30) is a reusable, aftermarket replacement (not OEM) direct-connect sensor that plugs straight into the monitor’s Datex-Ohmeda SpO2 port with no adapter cable, built to OEM fit, form, and function.
| Sensor Style | Finger Clip, Hard Shell |
| Patient Size | Adult, over 88 lbs (40 kg) |
| SpO2 Technology | Datex-Ohmeda |
| Cable Length | 10 ft (3.0 m) |
| Lifecycle | Reusable |
| Packaging | 1 Sensor per Bag |
| Replaces | Datex-Ohmeda / GE Healthcare OXY-F4-N, TS-F4-N; Datex-Ohmeda SAF-F4 |
Works with: select Datex-Ohmeda S/5, AS/3, CS/3, CS/5, Cardiocap, Light, and Satellite monitors, Aespire anesthesia systems, and M-series parameter modules. See the Specifications tab for the full list. Browse our full line of compatible SpO2 sensors and cables.
IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda and GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.
Warranty: 6-month IPR Medical limited warranty against defects in materials and workmanship unless a different period is stated on this page (Terms §5).
Specifications
| Product Type | Compatible Aftermarket Replacement (Non-OEM) |
| IPR Medical SKU | SS-014-AF30 |
| Replaces OEM Part Number | Datex-Ohmeda / GE Healthcare OXY-F4-N |
| Sensor Style | Finger Clip, Hard Shell |
| Sensor Configuration | Direct-Connect (No Adapter Cable Required) |
| Patient Size | Adult (over 88 lbs / 40 kg) |
| Usage | Reusable |
| Cable Length | 10 ft (3.0 m) |
| SpO2 Technology | Datex-Ohmeda |
| Monitor Connector | 10-Pin Datex-Ohmeda Direct-Connect |
| Sterile | No |
| Packaging | 1 Sensor per Bag |
| Manufacturing Standard | Produced in FDA-registered, ISO 13485:2016-certified facilities |
Compatible Monitor Models
| Manufacturer | Compatible Models |
| Datex-Ohmeda Monitors | S/5, S/5 with M-series modules, System 5, AS/3, AS/3 Compact, AS/3 with M-series modules, CS/3, CS/3 with M-series modules, CS/5, CS/5 Compact, Cardiocap I, Cardiocap II, Cardiocap/5, Cardiocap S/5 Light, Light Monitor |
| Datex-Ohmeda Anesthesia & Transport | Aespire, Aespire 15, Capnomac Ultima, Oscar II, OSP-200, Satellite, Satellite Plus II, Satellite Trans, Trans Plus, TruSignal |
| Datex-Ohmeda Modules & Units | M-ESTP, M-ESTPR, M-NESTPR, M-PRESTN, CG/2S, CH-RS, CH/2S, CH/S, ULTS00, ULTSIO, ULTSVI, ULTSVO |
| GE Healthcare | Datex-Ohmeda S5 |
Cross Reference / Interchange Part Numbers
| Manufacturer / Supplier | Part Number |
| Datex-Ohmeda (OEM) | OXY-F4-N, SAF-F4, TS-F4-N |
| GE Healthcare (OEM) | TS-F4-N |
| AMC | PR-A520-1005 |
| Beta Biomed | B505-1005 |
| Pacific Medical | NFDX200 |
| Sage | P05-307M |
| Tenacore | TCPF-2014-0322, TP2422 |
| Unimed | U410-09 |
| IPR Medical (Compatible) | SS-014-AF30 |
IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda S/5, AS/3, and Cardiocap/5 patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Datex-Ohmeda, GE Healthcare, Masimo, or any other manufacturer or supplier named on this page. Datex-Ohmeda, GE Healthcare, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
What Is the Datex-Ohmeda OXY-F4-N Compatible SpO2 Sensor?
The SS-014-AF30 is a compatible aftermarket replacement for the Datex-Ohmeda / GE Healthcare OXY-F4-N adult finger clip SpO2 sensor. It is not an OEM part. It is a reusable, direct-connect pulse oximetry sensor for continuous monitoring of oxygen saturation and pulse rate in adult patients. Common settings include the OR, PACU, ICU, and procedural areas. The cable runs directly from the finger clip to the monitor’s Datex-Ohmeda SpO2 input, so no separate adapter cable is required. The sensor is calibrated to Datex-Ohmeda oximetry technology, so readings stay consistent with what clinicians expect from the original part.
Compatible Monitor Models
This sensor works with a broad range of Datex-Ohmeda equipment. Compatible monitors include the S/5 and System 5, AS/3, AS/3 Compact, CS/3, CS/5, CS/5 Compact, Cardiocap I, Cardiocap II, Cardiocap/5, Cardiocap S/5 Light, and Light Monitor, including configurations with M-series modules. It is also compatible with the Aespire and Aespire 15 anesthesia systems. Transport and specialty units are covered as well: the Capnomac Ultima, Oscar II, OSP-200, Satellite, Satellite Plus II, Satellite Trans, Trans Plus, and TruSignal platforms. Compatible modules include the M-ESTP, M-ESTPR, M-NESTPR, and M-PRESTN, and the sensor also fits the GE Healthcare Datex-Ohmeda S5. Before ordering, confirm that the monitor uses Datex-Ohmeda SpO2 technology. Masimo- or Nellcor-equipped configurations require a different sensor.
Design and Construction
The sensor uses a hard-shell, spring-loaded finger clip that holds the emitter and detector in consistent alignment across the fingertip. This design is well suited to spot checks and short- to medium-term monitoring on adult patients over 88 lbs (40 kg). The 10 ft (3.0 m) cable reaches from bedside, boom-mounted, or anesthesia-machine monitors without straining the connector. The 10-pin Datex-Ohmeda connector plugs directly into the monitor’s SpO2 port. Each sensor ships non-sterile in an individual bag and is designed to be cleaned and disinfected between patients according to facility protocol.
When to Replace Your SpO2 Sensor
Reusable SpO2 sensors wear out from repeated cleaning, clip cycling, and cable flexing at the strain reliefs. Replace the sensor if any of the following apply:
The clip hinge or spring is weak, cracked, or no longer closes firmly. The emitter or detector windows are scratched or clouded. The cable jacket is cracked or stiff. Connector pins are bent or corroded.
Performance problems are also a sign of a failing sensor. Watch for “sensor off,” “no signal,” or “check sensor” alarms that persist on a well-perfused patient, weak or erratic plethysmograph waveforms, and readings that fluctuate when the cable is moved. A sensor that fails a check against an SpO2 simulator during preventive maintenance should be taken out of service immediately. Keep spares in the OR and PACU to avoid gaps in oximetry monitoring.
Cross Reference and Interchange Part Numbers
The SS-014-AF30 cross-references to Datex-Ohmeda OEM part numbers OXY-F4-N, SAF-F4, and TS-F4-N, and to GE Healthcare part number TS-F4-N. It also cross-references to the following aftermarket part numbers: AMC PR-A520-1005, Beta Biomed B505-1005, Pacific Medical NFDX200, Sage P05-307M, Tenacore TCPF-2014-0322 and TP2422, and Unimed U410-09. Materials managers can use any of these numbers to confirm fit when replacing existing stock or consolidating purchasing across facilities.
Why Source SpO2 Sensors from IPR Medical?
IPR Medical is an ISO 9001:2015-certified independent service organization specializing in patient monitoring and infusion equipment. We buy, sell, repair, and stock parts for Datex-Ohmeda and GE monitors, and our compatible accessories are held in inventory for fast shipping. Our in-house technical team helps biomedical departments confirm compatibility before purchase, match cross-reference numbers, and source hard-to-find parts. We also provide monitor repair, refurbishment, and equipment sales to support your fleet beyond accessories.
IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda S/5, AS/3, and Cardiocap/5 patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.
Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Datex-Ohmeda, GE Healthcare, Masimo, or any other manufacturer or supplier named on this page. Datex-Ohmeda, GE Healthcare, Masimo, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.
| Weight | 1 lbs |
|---|---|
| Dimensions | 8 × 8 × 6 in |
Reviews