IPR Medical

GE Healthcare 394111-009 / 394111-503 Compatible 6-Lead ApexPro FH Telemetry ECG Leadwire, Grabber/Pinch, Molded, 3 ft (0.9 m), AHA

$80.00

The GE Healthcare 394111-009 compatible 6-lead telemetry ECG leadwire is a reusable, aftermarket replacement (not OEM) for GE’s ApexPro FH 6-lead telemetry set (also referenced as 394111-503), built to match the original’s fit, form, and function.

Leads 6 (4 Limb + 2 Chest)
Transmitter-End Connector Molded ApexPro FH (DIN-Style)
Patient-End Connector Grabber/Pinch Clips
Lead Length 3 ft (0.9 m)
Color Code AHA (US)
Patient Size Adult/Pediatric
Construction Shielded, Reusable, Latex-Free

Works with: GE ApexPro FH telemetry transmitters and Mindray/Datascope DT-4500 telemetry. Browse more ECG/EKG cables and leadwires.

IPR Medical buys, sells, repairs, and stocks parts for GE patient monitoring and telemetry equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: EL-TAF6-90G-A Categories: , Tags: ,
Send In GE Healthcare 394111-009 / 394111-503 Compatible 6-Lead ApexPro FH Telemetry ECG Leadwire, Grabber/Pinch, Molded, 3 ft (0.9 m), AHA for Repair
Product Type Compatible Replacement (Aftermarket, Not OEM)
IPR Medical SKU EL-TAF6-90G-A
OEM Reference GE Healthcare 394111-009 / 394111-503
Lead Type GE ApexPro FH Telemetry
Lead Count 6 Leads
Lead Placement Limb + Chest (4 Limb, 2 Chest)
Color Code AHA (US)
Transmitter-End Connector Molded ApexPro FH Connector (DIN-Style)
Patient-End Connector Grabber/Pinch Clip
Leadwire Length 3 ft (0.9 m), Limb and Chest Leads
Shielding Shielded
Cable Jacket TPU, Gray
Cable Diameter 0.10 in (2.6 mm)
Patient Size Adult/Pediatric
Lifecycle Reusable
Latex-Free Yes
Sterile No
Packaging 1 per Bag
Weight 0.3 lbs

Compatible Equipment Models

Manufacturer Compatible Model
GE Healthcare / Marquette ApexPro FH Telemetry Transmitter
Mindray / Datascope DT-4500 Telemetry

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
GE Healthcare 394111-009
GE Healthcare 394111-503
Unimed AP6-90P

IPR Medical buys, sells, repairs, and stocks parts for GE ApexPro telemetry systems and GE patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, or any other manufacturer or supplier named on this page. GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the GE 394111-009 Compatible 6-Lead ApexPro FH Telemetry Leadwire?

The GE Healthcare 394111-009 compatible telemetry ECG leadwire is a reusable, aftermarket 6-lead set that connects a patient’s electrodes directly to a GE ApexPro FH telemetry transmitter. Six leads give four limb positions plus two chest positions, so the central station can display two precordial views at once. That gives clinicians more complete ischemia and arrhythmia surveillance than a single-V 5-lead setup, while the patient stays free to walk around the unit. It is a compatible replacement, not an original GE part, and it is built to the same fit, form, and function as the OEM 394111-009 and 394111-503 lead sets.


Compatible Equipment Models

This compatible 6-lead set is confirmed for use with the GE ApexPro FH telemetry transmitter and the Mindray/Datascope DT-4500 telemetry transmitter, which accepts the same molded lead set connector. Make sure the transmitter and central station are configured for 6-lead monitoring so both chest leads are displayed. This set is not for Multi-Link bedside trunk cables, which use a different connection.


Design and Construction

The six shielded leads are each 3 ft (0.9 m) long, giving enough slack for the second chest electrode while staying light for an ambulatory patient. All six leads come together in a single molded, DIN-style ApexPro FH connector that plugs directly into the transmitter and holds firmly as the patient moves. Spring-loaded grabber/pinch clips at the patient end attach to both tab and snap-style electrodes. The leads follow the AHA color code, and the gray TPU jacket is about 0.10 in (2.6 mm) in diameter for flexibility and comfort under a gown. The set is latex-free, non-sterile, rated for adult and pediatric patients, weighs about 0.3 lbs, and ships one per bag.


When to Replace Your ApexPro FH 6-Lead Telemetry Leadwire

With two chest leads crossing the torso, 6-lead telemetry sets see extra tension and twisting as patients sit up, walk, and change position. Replace the set when either chest lead shows persistent artifact or “leads off” alarms despite fresh electrodes, when grabber clips lose their grip, when the molded connector no longer seats securely in the transmitter, or when you see cracked jacketing, exposed shielding, or worn color coding. Since the value of a 6-lead set is its second precordial view, a failing chest lead should be treated as a reason to replace the whole set.


Cross Reference and Interchange Part Numbers

This compatible 6-lead ApexPro FH telemetry leadwire, IPR Medical SKU EL-TAF6-90G-A, cross-references to GE Healthcare part numbers 394111-009 and 394111-503 and to Unimed part number AP6-90P. Materials managers and purchasing staff can use any of these numbers to confirm the match against existing inventory, work orders, or requisitions. For 5-lead ApexPro FH monitoring, IPR Medical also stocks the compatible GE 394111-005 grabber set.


Why Source Telemetry Leadwires from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring, telemetry, and infusion equipment. We carry compatible ApexPro FH lead sets in both 5- and 6-lead configurations, so cardiac and step-down units can stock the right mix for their monitoring protocols at lower cost than OEM. Our team can help confirm lead set compatibility with your transmitters and support your telemetry and monitoring equipment with in-house repair services.

IPR Medical buys, sells, repairs, and stocks parts for GE ApexPro telemetry systems and GE patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by GE Healthcare, or any other manufacturer or supplier named on this page. GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.