Skip to content
IPR Medical

Datex-Ohmeda / GE Compatible Adult/Pediatric Dual-Tube NIBP Air Hose, 11.8 ft (3.6 m) – 9461-214

$50.00

The Datex-Ohmeda / GE Healthcare 9461-214 compatible adult/pediatric dual-tube NIBP air hose (SKU BPH-AD36-13-09M) is a reusable aftermarket replacement (not OEM) built to OEM fit, form, and function for use with 2-tube adult and pediatric cuffs with screw (threaded) connectors.

Hose Type Dual Tube
Patient Size Adult / Pediatric
Hose Length 11.8 ft (3.6 m)
Compatible Cuff Type 2-Tube Adult/Pediatric Cuff with Screw (Threaded) Connectors
Lifecycle Reusable
Packaging 1 Hose per Bag
Replaces Datex-Ohmeda / GE Healthcare 9461-214

Works with: Datex-Ohmeda S/5, AS/3, CS/3, Cardiocap II, Cardiocap/5, and Light monitors; GE Marquette Solar, Eagle 4000, and Tram 100 through 350 series; GE Corometrics 120 Series; and Criticare/CSI 500 and 507. Browse our full line of compatible NIBP hoses and cuffs.

IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda and GE patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: datex-ohmeda-nibp-air-hose-9461-214 Categories: , Tags: , , Brand:
Send In Datex-Ohmeda / GE Compatible Adult/Pediatric Dual-Tube NIBP Air Hose, 11.8 ft (3.6 m) – 9461-214 for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Non-OEM)
IPR Medical SKU BPH-AD36-13-09M
Replaces OEM Part Number Datex-Ohmeda / GE Healthcare 9461-214
Hose Type Dual Tube
Patient Size Adult / Pediatric
Hose Length 11.8 ft (3.6 m)
Monitor-End Connector Dual Connector (Datex-Ohmeda / GE NIBP Port)
Compatible Cuff Type 2-Tube Adult/Pediatric Cuff with Screw (Threaded) Connectors
Usage Reusable
Sterile No
Packaging 1 Hose per Bag
Manufacturing Standard Produced in FDA-registered, ISO 13485:2016-certified facilities

Compatible Monitor Models

Manufacturer Compatible Models
Datex-Ohmeda S/5, AS/3, CS/3, Cardiocap II, Cardiocap/5, Light
GE Healthcare / Marquette Solar, Eagle 4000, Tram 100, Tram 200, Tram 250, Tram 300, Tram 350
GE Healthcare / Corometrics 120 Series
Criticare / CSI 500, 507

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Datex-Ohmeda / GE Healthcare (OEM) 9461-214
Unimed HD36-22-09
IPR Medical (Compatible) BPH-AD36-13-09M

IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda S/5 and GE Marquette patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Datex-Ohmeda, GE Healthcare, or any other manufacturer or supplier named on this page. Datex-Ohmeda, GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Datex-Ohmeda 9461-214 Compatible NIBP Hose?

The BPH-AD36-13-09M is a compatible aftermarket replacement for the Datex-Ohmeda / GE Healthcare 9461-214 adult/pediatric NIBP air hose. It is not an OEM part. This reusable dual-tube hose connects the monitor’s non-invasive blood pressure port to a 2-tube adult or pediatric cuff. It carries inflation pressure to the cuff and returns the oscillometric pressure signal to the monitor. The hose is used in the OR, PACU, ICU, and general med-surg units. It is built to match the OEM part’s fit, connectors, and pneumatic performance, so readings in mmHg stay consistent with the original.


Compatible Monitor Models

This hose is compatible with the Datex-Ohmeda S/5, AS/3, CS/3, Cardiocap II, Cardiocap/5, and Light monitors. It is also compatible with the GE Healthcare Marquette Solar, Eagle 4000, and Tram 100, 200, 250, 300, and 350 modules, and with the GE Corometrics 120 series. Criticare/CSI 500 and 507 monitors are supported as well. Before ordering, confirm that your monitor’s NIBP port uses the dual-tube connector this hose is designed for, and that your cuffs use screw (threaded) connectors.


Design and Construction

The hose is 11.8 ft (3.6 m) long with a dual-tube design. The extra length reaches from wall-mounted, boom-mounted, or anesthesia-machine monitors to the patient without pulling on the cuff or the NIBP port. The monitor end has a dual connector that seats directly into the Datex-Ohmeda / GE NIBP port. The patient end accepts 2-tube adult and pediatric cuffs with screw (threaded) connectors, which lock in place and resist accidental disconnection during transfers. Each hose ships non-sterile in an individual bag. It is designed to be wiped down and disinfected between patients according to facility protocol.


When to Replace Your NIBP Hose

NIBP hoses develop leaks over time. Common causes are kinking, being crushed under bed rails and wheels, and repeated connecting and disconnecting. Replace the hose if the tubing is cracked, stiff, discolored, or permanently kinked. Also replace it if the threads on either connector are worn or cross-threaded, or if a connector no longer seals tightly. Some alarms point to a failing hose when they persist with a known-good cuff: “cuff leak,” “unable to measure,” or excessive inflation time. Readings that vary more than expected between consecutive measurements are another sign. Remove a hose from service right away if it fails a leak or static pressure check during preventive maintenance. Keeping spares in high-use areas such as the OR and PACU prevents gaps in blood pressure monitoring.


Cross Reference and Interchange Part Numbers

The BPH-AD36-13-09M cross-references to Datex-Ohmeda / GE Healthcare OEM part number 9461-214 and to Unimed part number HD36-22-09. Materials managers can use any of these numbers to confirm fit when replacing existing stock or consolidating purchasing across facilities. This hose is for adult and pediatric cuffs with screw connectors. Neonatal cuffs require a separate neonatal hose, such as the 877514 compatible replacement.


Why Source NIBP Hoses from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization specializing in patient monitoring and infusion equipment. We buy, sell, repair, and stock parts for Datex-Ohmeda and GE monitors, and we keep our compatible accessories in inventory so orders ship quickly. Our in-house technical team helps biomedical departments confirm compatibility before purchase, match cross-reference numbers, and source hard-to-find parts. Beyond accessories, we also provide monitor repair, refurbishment, and equipment sales to support your fleet.

IPR Medical buys, sells, repairs, and stocks parts for Datex-Ohmeda S/5 and GE Marquette patient monitors. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Datex-Ohmeda, GE Healthcare, or any other manufacturer or supplier named on this page. Datex-Ohmeda, GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.