Skip to content
IPR Medical

Datex-Ohmeda 877235 Compatible NIBP Air Hose, Adult/Pediatric, Dual Tube, 8.2 ft (2.5 m)

$50.00

Datex-Ohmeda 877235 Compatible NIBP Air Hose (SKU BPH-AD25-13-1011) is a compatible aftermarket replacement (not OEM) for the Datex-Ohmeda 877235. It is a reusable adult/pediatric dual-tube blood pressure hose, 8.2 ft (2.5 m) long.

Replaces Datex-Ohmeda / GE Healthcare 877235
Patient Size Adult/Pediatric
Tubing Dual Tube (2-Tube)
Used with Cuff 2-Tube Mated Submin Cuff
Hose Length 8.2 ft (2.5 m)
Lifecycle Reusable

Works with: select Datex-Ohmeda monitors such as the Cardiocap, S/5, AS/3, and CS/3, GE Healthcare / Marquette Eagle, Solar, and Tram models, and the Omron / Colin VP-1000/2000. See the Specifications tab for the full compatibility list.

IPR Medical buys, sells, repairs, and stocks parts for patient monitoring equipment. Call 855-477-8866 or email cs@iprmed.com.

SKU: datex-ohmeda-nibp-air-hose Categories: , Brand:
Send In Datex-Ohmeda 877235 Compatible NIBP Air Hose, Adult/Pediatric, Dual Tube, 8.2 ft (2.5 m) for Repair

Specifications

Product Type Compatible Aftermarket Replacement (Not OEM)
IPR Part Number (SKU) BPH-AD25-13-1011
Replaces OEM Part Datex-Ohmeda / GE Healthcare 877235
Category Cables & Sensors > NIBP
Product NIBP (Blood Pressure) Air Hose
Patient Size Adult/Pediatric
Tubing Dual Tube (2-Tube)
BP Plug Dual PLC
Used with Cuff 2-Tube Mated Submin Cuff
Hose Length 8.2 ft (2.5 m)
Lifecycle Reusable
Packaging 1 per bag

Compatible Monitor Models

Manufacturer Compatible Models
Datex-Ohmeda AS/3, CS/3, Cardiocap II, Cardiocap/5, Light, M-NESTPR, M-NESTR, M-PRESTN, S/5
GE Healthcare / Marquette Eagle 4000, Solar, Tram 100, Tram 200, Tram 300
Omron / Colin VP-1000/2000

Cross Reference / Interchange Part Numbers

Manufacturer / Supplier Part Number
Datex-Ohmeda / GE Healthcare 877235
AMC HO-D2217188-10
Unimed HD-22-17/18

IPR Medical buys, sells, repairs, and stocks parts for NIBP hoses and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Datex-Ohmeda, GE Healthcare, or any other manufacturer or supplier named on this page. Datex-Ohmeda, GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

What Is the Datex-Ohmeda 877235 Compatible NIBP Air Hose?

The IPR Medical BPH-AD25-13-1011 is a compatible aftermarket non-invasive blood pressure (NIBP) air hose that replaces the Datex-Ohmeda 877235 (not an OEM part). It is an adult/pediatric dual-tube hose that forms the air pathway between the monitor and the blood pressure cuff, carrying inflation pressure to the cuff and the pressure signal back to the monitor. At 8.2 ft (2.5 m), it gives clinicians room to position the patient and route the hose at the bedside.


Compatible Monitor Models

This hose is listed as compatible with select Datex-Ohmeda monitors and modules, including the AS/3, CS/3, Cardiocap II, Cardiocap/5, Light, and S/5 and the M-NESTPR, M-NESTR, and M-PRESTN modules, select GE Healthcare / Marquette Eagle 4000, Solar, and Tram models, and the Omron / Colin VP-1000/2000. See the Compatible Monitor Models table on the Specifications tab for the complete list, and confirm your monitor model before ordering.


Design and Construction

The hose uses a dual-tube design with a dual PLC BP plug and is intended for use with 2-tube mated submin cuffs on adult and pediatric patients. It measures 8.2 ft (2.5 m) and ships one per bag. As a reusable accessory, it can be cleaned between patients per facility protocol and the manufacturer’s instructions for your monitor, and kept in service as long as it passes inspection.


When to Replace Your NIBP Air Hose

Replace the hose when you see cracked, brittle, or discolored tubing, kinks that do not relax, or a loose, cracked, or damaged connector at the monitor or cuff end. Air leak alarms, slow or incomplete cuff inflation, repeated failed or aborted measurements, and readings that change when the hose is moved are also common signs of a failing hose. Swapping in a known-good hose is a quick way for biomedical staff to isolate whether the hose, the cuff, or the monitor is at fault.


Cross Reference and Interchange Part Numbers

This compatible hose replaces Datex-Ohmeda / GE Healthcare 877235. It also cross-references to AMC HO-D2217188-10 and Unimed HD-22-17/18. All interchange numbers are listed in the Cross Reference / Interchange Part Numbers table on the Specifications tab.


Why Source NIBP Hoses from IPR Medical?

IPR Medical is an ISO 9001:2015-certified independent service organization that buys, sells, repairs, and stocks parts for patient monitoring equipment and infusion pumps. Our in-house technicians service patient monitoring equipment, so we can help you confirm the right hose for your equipment and keep your fleet in service. Browse more NIBP hoses, cuffs, and accessories in our NIBP category, or call 855-477-8866 for help with ordering, repairs, or parts.

IPR Medical buys, sells, repairs, and stocks parts for NIBP hoses and the patient monitors they connect to. Contact us at 855-477-8866 or cs@iprmed.com.

Trademark Notice: This is a compatible aftermarket product. It is not manufactured, sold, licensed, or endorsed by Datex-Ohmeda, GE Healthcare, or any other manufacturer or supplier named on this page. Datex-Ohmeda, GE Healthcare, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the equipment this product is compatible with and the OEM parts it can replace, consistent with nominative fair use. IPR Medical is an ISO 9001:2015-certified independent service organization; references to OEM equipment describe the equipment we sell, service, and support, and do not indicate any affiliation with, sponsorship by, or endorsement from its manufacturer.

Weight 1 lbs
Dimensions 8 × 8 × 6 in

Reviews

There are no reviews yet.