IPR Medical

Recertified

Baxter Flo-Gard 6200

$895.00 Original price was: $895.00.$795.00Current price is: $795.00.

The Baxter Flo-Gard 6200 is a single-channel volumetric infusion pump built for reliable, accurate intravenous delivery of a wide range of fluids — including blood and fat emulsions — across primary and secondary infusion programs. Operating on standard 115 VAC power or its self-contained rechargeable battery, it delivers flow rates from 1 to 999 mL/hr in 1 mL/hr increments with a VTBI range of 1 to 9,999 mL. Automatic piggybacking switches seamlessly from the secondary program back to the primary when secondary infusion completes, and a built-in safety clamp prevents accidental free flow any time the pump door is opened.

The Flo-Gard 6200 is an older pump — discontinued by Baxter — but it remains one of the most straightforward, dependable large-volume pumps in clinical use today. Hospitals, long-term care facilities, outpatient clinics, and veterinary practices continue to rely on them for good reason: they are simple to load, simple to program, and built to last.

IPR Medical maintains a large inventory of Flo-Gard 6200 parts — including batteries, fuses, pump mechanisms, power cords, and more — to keep your fleet running strong. Whether you need a single unit serviced or a supply of components to support ongoing maintenance, we have what you need.

SKU: baxter-flo-gard-6200 Category: Brand:
Send In Baxter Flo-Gard 6200 for Repair

Baxter Flo-Gard® 6200 Volumetric Infusion Pump

Single-channel volumetric infusion pump for primary and secondary IV therapy. Delivers 1–999 mL/hr across a VTBI range of 1–9,999 mL with automatic piggybacking, upstream and downstream occlusion detection, ultrasonic air-in-line sensing, and gravity free-flow protection. Operates on AC power or internal rechargeable battery. IPR Medical carries a large inventory of Flo-Gard 6200 parts to keep your units running strong.


Flow Rate — Primary 1 to 999 mL/hr in 1 mL/hr increments
Flow Rate — Secondary 1 to 999 mL/hr in 1 mL/hr increments
VTBI Range 1 to 9,999 mL (primary and secondary, independently tracked)
KVO Rate 1 to 5 mL/hr
Automatic Piggybacking Yes — secondary program automatically switches to primary on completion
Air-in-Line Detection Ultrasonic — detects air bubbles 1/3 in (0.05 mL) or larger
Occlusion Detection Upstream and downstream
Free-Flow Protection Automatic safety clamp occludes tubing when pump door is opened
Panel Lockout Yes — locks control panel to prevent patient tampering
Administration Set Baxter standard administration sets; luer lock recommended for central venous catheters
Power — AC 115 VAC, 60 Hz, 10 watts
Power — DC (Battery) Internal rechargeable 8-volt sealed lead-acid battery
Battery Life Approx. 5 hours at 125 mL/hr (fully charged)
Battery Charge Time 24 hours to fully recharge
Power Cord Replaceable, 2.4 m (8 ft) with hospital-grade plug
Fuses Type 0.5A, 250V, SB 6.35 mm
Leakage Current Less than 20 microamps (per UL 544)
Operating Temperature 10°C to 40°C (50°F to 104°F)
Outer Casing Molded plastic
Dimensions (W × D × H) 24 cm × 16 cm × 27 cm (9.5 in × 6 in × 11 in)
Weight Approx. 6.7 kg (14 lbs)

IPR Medical maintains a large inventory of Flo-Gard 6200 parts — including batteries, fuses, power cords, pump mechanisms, and more. Contact us to keep your fleet running strong.

Trademark Notice: Baxter, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Baxter.

Dependable large-volume infusion — simple by design

The Baxter Flo-Gard 6200 is an electro-mechanical volumetric infusion pump designed for the intravenous delivery of a wide variety of fluids, including blood and fat emulsions, at user-selected rates. It is an older, discontinued model — but it has remained in active clinical service across hospitals, long-term care facilities, outpatient clinics, and veterinary practices for one straightforward reason: it works, and it keeps working. The Flo-Gard 6200 is easy to load, straightforward to program, and built with a mechanical reliability that modern facilities still count on.


Primary, secondary, and automatic piggybacking

The Flo-Gard 6200 supports both primary and secondary infusion programs with independently tracked VTBIs from 1 to 9,999 mL and flow rates from 1 to 999 mL/hr. When a secondary infusion completes, the pump automatically switches back to the primary program — no manual intervention required. Total volumes from both programs accumulate and can be displayed on demand, simplifying documentation at the bedside. Upon completion of the primary VTBI, the pump transitions to a keep-vein-open rate of 1 to 5 mL/hr to maintain line patency.


Safety features built into the hardware

The Flo-Gard 6200 includes an ultrasonic air-in-line detector that senses bubbles 0.05 mL or larger without nuisance alarms, upstream and downstream occlusion sensors, and a gravity free-flow safety clamp that automatically occludes the tubing any time the pump door is opened — preventing accidental free flow during set changes. A front-panel lockout feature discourages patient tampering without requiring staff to intervene. The spill-resistant pumping mechanism and molded plastic casing hold up to the demands of everyday clinical environments.


AC and battery operation

The Flo-Gard 6200 runs on standard 115 VAC, 60 Hz power or its internal 8-volt sealed lead-acid rechargeable battery, providing approximately 5 hours of runtime at 125 mL/hr on a full charge. The 8-foot hospital-grade power cord is replaceable, and fuses are user-accessible — both practical features for facilities managing a large pump fleet.


IPR Medical keeps your Flo-Gard 6200 fleet running

The Flo-Gard 6200 is a discontinued product, but the demand for parts and service remains strong. IPR Medical maintains a large inventory of Flo-Gard 6200 replacement parts — including batteries, fuses, power cords, pump mechanisms, and additional components — so your units don’t have to come out of service when something wears out. Every pump we sell is fully inspected, tested, and patient-ready before it ships.

Need parts, repairs, or fleet pricing? IPR Medical stocks a large inventory of Baxter Flo-Gard 6200 components. Contact us for parts availability, repair turnaround, and volume pricing on units and parts.

Trademark Notice: Baxter, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Baxter.

Weight 14 lbs
Dimensions 14 × 14 × 14 in
Product Condition

Refurbished / Patient Ready

  • Power Cord

Reviews

There are no reviews yet.

You may also like…