Philips IntelliVue M3001A Multi-Measurement Module | Option A04, Nellcor OxiMax SpO2

$1,095.00 Original price was: $1,095.00.$995.00Current price is: $995.00.

The Philips IntelliVue M3001A (Option A04) is the newer-hardware-generation Nellcor OxiMax-compatible configuration of the IntelliVue Multi-Measurement Module. Like the A02, the A04 uses a dedicated Nellcor OxiMax-compatible SpO2 interface and delivers the same core clinical measurement set — ECG, arrhythmia, ST, respiration, OxiMax SpO2, and oscillometric NBP — to any compatible IntelliVue host monitor. The defining distinction from the A02 is internal: the A04 runs on the newer hardware revision C platform, identified by serial number prefixes DE610, DE632, DE717, and DE907, which integrates the DC/DC power circuit onto the main board rather than as a separate component. This hardware generation supports a wider range of IntelliVue software revisions and uses a distinct parameter board assembly. The A04 is the correct Nellcor OxiMax module choice for facilities sourcing units or parts for newer-generation M3001A hardware, or for host monitors requiring hardware revision C compatibility.

Part Number / Option M3001A, Option A04
Parameters Monitored ECG (3/5-lead), Arrhythmia, ST, Respiration, Nellcor OxiMax SpO2, NBP (oscillometric)
SpO2 Technology Nellcor OxiMax-compatible — for use with Nellcor OxiMax sensor line via M1943NL adapter cable
Hardware Generation Revision C — serial number prefixes DE610, DE632, DE717, DE907; newer platform vs. A02
Host Monitor Compatibility IntelliVue MP20/30/40/50/60/70/80/90; MX-series; M3046A (M/M4)
Data Storage Up to 8 hrs of trend data at 1-min resolution stored in module; retained 6 hrs while disconnected

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact us at 855-477-8866 or cs@iprmed.com.

SKU: philips-intellivue-m3001a-a04 Categories: , Brand:
Send In Philips IntelliVue M3001A Multi-Measurement Module | Option A04, Nellcor OxiMax SpO2 for Repair

Philips IntelliVue M3001A — Specifications (Option A04)


Manufacturer Philips Healthcare
Model IntelliVue Multi-Measurement Module (MMS)
Part Number / Catalog Number M3001A
Option Covered by This Listing A04 — Nellcor OxiMax-compatible SpO2, ECG/Respiration, NBP (standard package; no invasive pressure or temperature)
Hardware Generation Hardware Revision C — newer internal platform; serial number prefixes DE610, DE632, DE717, and DE907; DC/DC power circuit integrated onto main board (not a separate board as in HW Rev A/B used by A02)
Parameter Board OEM Part Number M3001-68555 (451261020791) — not interchangeable with A02 parameter board
Device Classification Multi-parameter Multi-Measurement Module (MMS) for use with IntelliVue host patient monitors
Intended Use Acquisition and transmission of physiological measurement data — ECG, arrhythmia, ST, respiration, SpO2, and NBP — to a compatible IntelliVue host patient monitor. The MMS stores patient demographics, trends, and settings and supports seamless patient data transfer between compatible host monitors.
Parameters — Option A04 Standard Package ECG (3-lead and 5-lead), Arrhythmia, ST Segment, Respiration (impedance), Nellcor OxiMax-compatible SpO2 / Pleth, Pulse Rate, NBP (oscillometric)
ECG Leads 3-lead and 5-lead monitoring configurations; a 10-electrode lead set can be connected but only standard 5 electrodes (RA, LA, RL, LL, V) are used for monitoring in Option A04
12-Lead ECG Not included in Option A04. Available with Option A04C12 (conventional 12-lead) or Option A04C18 (12-lead + invasive pressure/temperature)
Arrhythmia Detection Yes — full arrhythmia monitoring and alarm capability via host monitor
ST Segment Analysis Yes — ST monitoring with alarms via host monitor display
NIBP Method Oscillometric
SpO2 Technology Nellcor OxiMax-compatible SpO2 (Option A04) — for direct use with Nellcor OxiMax sensors; requires OxiMax-specific adapter cable (M1943NL) for connection
Invasive Pressure / Temperature Not included in Option A04. Available with Option A04C06 (one invasive pressure + temperature channel) or Option A04C18
Trend Storage Up to 8 hours of trend data at 1-minute resolution for all numeric parameters, stored within the MMS itself
Data Retention While Disconnected Patient demographics, trends, and active parameter settings are retained in the MMS for up to 6 hours while disconnected from a host monitor
Connection to Host Monitor Direct cable-free attachment to rear of compatible IntelliVue host monitor, or via MSL (Measurement Link) cable for remote placement in patient vicinity
Host Monitor Compatibility Philips IntelliVue MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90; MX-series monitors; M3046A (M/M4 series, Release E and later)
Optional MMS Extensions M3015A (sidestream CO2); M3016A (mainstream CO2); M3012A (additional invasive pressure/temperature/CO2)
Power Source Powered by host monitor via MSL connection; no independent battery or AC power supply
Preventive Maintenance NBP calibration test required once every two years per OEM service documentation
Regulatory FDA 510(k) cleared; product code MHX (Class II); CE marked

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, Nellcor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips or Nellcor.

Overview

The Philips IntelliVue M3001A (Option A04) is the newer-hardware-generation Nellcor OxiMax-compatible configuration of the IntelliVue Multi-Measurement Module. Like the A02, it provides Nellcor OxiMax-compatible SpO2 alongside ECG with arrhythmia and ST monitoring, impedance respiration, and oscillometric NBP to any compatible IntelliVue host monitor. The clinical measurement set is identical to the A02 — the distinction is entirely internal. The A04 is built on Hardware Revision C, the newest internal platform for the M3001A product line, identified by serial number prefixes DE610, DE632, DE717, and DE907. On this hardware generation, the DC/DC power circuit is integrated onto the main board rather than implemented as a separate component as in the earlier HW Rev A and HW Rev B units associated with the A02 option. This integration simplifies the internal assembly, changes which replacement parts are applicable, and affects software revision compatibility at the top end of the supported range. Facilities purchasing M3001A A04 units or parts should confirm that their host monitor software revision falls within the compatibility range for HW Rev C hardware. All other operational characteristics — data storage, host compatibility, MMS extension support, and SpO2 sensor interface — are the same as the A02.


Option A04 vs. A02 — Understanding the Hardware Difference

Both the A02 and A04 use a Nellcor OxiMax-compatible SpO2 interface, accept the same OxiMax sensors via the M1943NL adapter cable, and deliver the same clinical parameters. The difference between them is hardware generation, not clinical capability. Philips produced the M3001A across multiple internal hardware revisions over the product’s lifespan. The A02 option is associated with HW Rev A and HW Rev B units, which include a separate DC/DC board as a distinct internal component. The A04 option is associated with HW Rev C units — serial number prefixes DE610, DE632, DE717, and DE907 — where the DC/DC power circuit has been integrated onto the main board, per Philips service documentation (SB86200577). This architectural change means the parameter board part numbers differ between the two options: the A04 uses OEM parameter board M3001-68555, while the A02 uses a different assembly. These boards are not interchangeable. For biomedical technicians, this matters when ordering replacement parts — always confirm the hardware revision from the serial number prefix and option string on the module’s rear label before sourcing internal components. For clinical purchasing teams, the A02 and A04 are operationally equivalent: same sensors, same cables, same measurements, same host monitor compatibility range.


Nellcor OxiMax SpO2 and NBP Measurement

The Nellcor OxiMax-compatible SpO2 interface in the M3001A A04 provides SpO2 saturation, pulse rate, and a real-time plethysmogram waveform using the same OxiMax sensor ecosystem as the A02. OxiMax sensors connect to the module’s SpO2 port via the M1943NL adapter cable, which provides the 8-pin D-Connect to OxiMax interface. The OxiMax platform — now maintained by Medtronic — includes a broad catalog of adult, pediatric, and neonatal sensors for finger, forehead, ear, and multisite applications, and each OxiMax sensor carries an embedded identification chip that communicates sensor type and calibration status to the monitor. Facilities already running Nellcor OxiMax sensors on A02 modules will find the A04 uses identical sensors and the same adapter cable, making the two options functionally interchangeable at the bedside. Non-invasive blood pressure measurement uses the oscillometric method, configured through the host IntelliVue monitor’s interface, with NBP results feeding into the module’s trend record. The NBP pneumatic assembly requires a calibration performance check once every two years per OEM service documentation.


Clinical Measurements — ECG, Arrhythmia, and ST

ECG monitoring in the M3001A A04 supports 3-lead and 5-lead configurations using the connected ECG trunk cable and leadset. Arrhythmia analysis is processed through the host IntelliVue monitor’s alarm system and delivers notification for lethal and non-lethal rhythm events with configurable alarm limits and lead selection. ST segment monitoring provides continuous analysis of elevation and depression across the monitored leads, with threshold-based alarms and on-screen visualization on the host display. Respiration rate is derived from thoracic impedance using the ECG electrodes already in place, requiring no additional sensors beyond the ECG cable setup. All alarm processing and parameter display are managed by the host IntelliVue monitor once the M3001A is docked or connected via MSL cable. The A04 option designation applies only to the SpO2 interface and internal hardware platform — the ECG, arrhythmia, ST, and respiration hardware performs identically to the A02 and other M3001A variants.


Patient Data Portability and Trend Storage

The M3001A A04 stores its patient record internally, following the same architecture used across all M3001A configurations. Up to eight hours of numeric trend data at one-minute resolution, patient demographic information, active measurement settings, and NBP calibration data are all resident within the module itself rather than on the host monitor. When the A04 connects to a new IntelliVue host, this data uploads automatically without manual re-entry, giving the receiving monitor a complete longitudinal view of the patient’s vital signs. The module retains the full patient record for up to six hours while disconnected from any host, supporting clean handoffs between units, procedure areas, and monitoring locations without data loss. Facilities running OxiMax sensors will find that both the A02 and A04 travel with the patient in exactly the same way — the same Nellcor sensor remains attached, the same trend data persists in the module, and reconnection to any compatible IntelliVue host instantly restores the full monitoring record.


MMS Extensions and Configuration Upgrades

The M3001A A04 standard package covers ECG, respiration, Nellcor OxiMax SpO2, and NBP. Facilities requiring invasive pressure and temperature measurement can source the A04C06 configuration, which adds one invasive pressure channel and one temperature channel. The A04C12 configuration adds conventional 12-lead ECG capability using a 10-electrode lead set. The A04C18 configuration provides the full complement — 12-lead ECG, invasive pressure, and temperature — alongside the A04 standard parameters. MMS extension modules can also be physically attached to expand measurement capability: the M3015A adds sidestream CO2; the M3016A adds mainstream CO2; and the M3012A adds an additional invasive pressure channel, temperature, and CO2 in a single unit. These extensions attach directly to the M3001A and inherit power and network connectivity from the host monitor through the module, requiring no separate power supply or dedicated MSL cable.


Host Monitor Connectivity and System Integration

The M3001A A04 connects to compatible IntelliVue host monitors in the same two physical configurations used by all M3001A variants — direct dock to the rear of the host monitor, or remote via MSL cable. Once connected, all monitoring and alarm functions are managed through the host monitor’s interface. The A04 is compatible with the full IntelliVue MP-series platform (MP20 through MP90), the MX-series monitors, and the M3046A (M/M4 series) running Release E or higher. Biomedical staff should verify that the specific host monitor’s software revision is supported by the HW Rev C hardware before deploying A04 units; Philips published compatibility matrix charts correlating M3001A serial number prefix to supported software revisions, and IPR Medical can assist in confirming compatibility for specific fleet configurations. When the host monitor is networked to the IntelliVue Information Center, all measurement data from the M3001A A04 flows transparently for central monitoring, trend archiving, and reporting alongside all other networked patient data.


IPR Medical — Buy, Sell, Repair, and Parts

IPR Medical is a secondary market specialist for Philips IntelliVue patient monitoring equipment, including the M3001A Multi-Measurement Module across all option configurations and hardware revisions. For the M3001A A04 specifically, IPR Medical purchases HW Rev C units, sells tested and refurbished modules, and provides repair services for component-level issues including the NBP pneumatic assembly, OxiMax SpO2 interface circuitry, ECG acquisition hardware, and MSL connectivity. Because the A04 uses hardware-revision-specific internal components — including the M3001-68555 parameter board — IPR Medical’s familiarity with the M3001A hardware revision structure is an important asset when sourcing replacement parts or evaluating repair options. IPR Medical also stocks commonly requested accessories for the A04, including ECG trunk cables and leadsets, the M1943NL OxiMax adapter cable, Nellcor OxiMax sensors, NIBP cuffs and hoses, and MSL cables. Contact our team to confirm current unit availability, hardware revision, or parts compatibility for your specific fleet.

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.

Trademark Notice: Philips, Nellcor, and all other brand names, model names, and part numbers shown are trademarks of their respective owners and are used on this page only to identify the original manufacturer’s equipment offered here, consistent with nominative fair use. This listing is offered by IPR Medical, an ISO 9001:2015-certified independent service organization, and is not sponsored by, affiliated with, or endorsed by Philips or Nellcor.

Weight 1 lbs
Dimensions 8 × 6 × 4 in
Output Options

A01 – Fast SPO2, NIBP, ECG/RESP, A01C06 – Fast SPO2, NIBP, ECG/RESP, IBP, A01C12 – Fast SPO2, NIBP, 12 ECG/RESP, A01C18 – Fast SPO2, NIBP, 12 ECG/RESP, IBP, A2 – Nellcor Oximax SPO2, NIBP, ECG/RESP, A02C06 – Nellcor Oximax SPO2, NIBP, ECG/RESP, IBP, A02C12 – Nellcor Oximax SPO2, NIBP, 12 Lead ECG/RESP, A02C18 – Nellcor Oximax SPO2, NIBP, 12 Lead ECG/RESP, IBP, A03 – Masimo SET SPO2, NIBP, ECG/RESP, A03C06 – Masimo SET SPO2, NIBP, ECG/RESP, IBP, A03C12 – Masimo SET SPO2, NIBP, 12 ECG/RESP, A03C18 – Masimo SET SPO2, NIBP, 12 ECG/RESP, IBP, A04 – Nellcor Oximax SPO2, NIBP, ECG/RESP, A04C06 – Nellcor Oximax SPO2, NIBP, ECG/RESP, IBP, A04C12 – Nellcor Oximax SPO2, NIBP, 12 Lead ECG/RESP, A04C18 – Nellcor Oximax SPO2, NIBP, 12 Lead ECG/RESP, IBP

Compatible Parts and Accessories

IPR Medical stocks a range of compatible parts and accessories for the Philips IntelliVue M3001A (Option A04). The sections below cover the most commonly requested components. Contact us at 855-477-8866 or cs@iprmed.com to confirm availability, pricing, or compatibility for your specific hardware revision and configuration.


Internal Replacement Parts (Hardware Revision C Specific)

M3001-68555 (451261020791) OEM parameter board for M3001A Option A04 — Nellcor OxiMax SpO2, NBP, 5-lead ECG; for hardware revision C units (serial number prefixes DE610, DE632, DE717, DE907) only; not interchangeable with A02 parameter board
NBP pump assembly Replacement NBP pump for M3001A HW Rev C — contact IPR Medical to confirm correct part number for your serial number prefix; pump assembly differs between HW revisions

MMS Extension Modules

M3015A Sidestream CO2 Measurement Server Extension — attaches to the M3001A to add sidestream capnography; powered via host monitor MSL connection
M3016A Mainstream CO2 Measurement Server Extension — attaches to the M3001A to add mainstream capnography; powered via host monitor MSL connection
M3012A Hemodynamic/Pressure/Temperature MMS Extension — adds an additional invasive pressure channel, temperature, and CO2 capability to the M3001A

ECG Cables and Leadsets

M1668A 5-lead ECG trunk cable (12-pin connector) — compatible with M3001A; also accepts 3-lead sets
M1669A 3-lead ECG trunk cable — compatible with M3001A for 3-lead monitoring configurations
M1977A 5-lead ECG set, direct-connect pinch/grabber leadwires — for use with M3001A compatible trunk cables (AAMI color coding)
3-lead direct-connect leadwires 3-lead snap and pinch/grabber leadwire sets compatible with M3001A trunk cables — contact IPR Medical to confirm specific part numbers available

SpO2 Adapter Cable (Required for OxiMax Sensors)

M1943NL Philips SpO2 adapter cable — 8-pin D-Connect to OxiMax interface; required to connect Nellcor OxiMax sensors to the M3001A Option A04 SpO2 port; same cable used with Option A02

Nellcor OxiMax SpO2 Sensors

M4789A / M4789B Nellcor OxiMax SpO2 finger probe sensors — adult; for use with M3001A Option A04 via M1943NL adapter cable
P3119A Nellcor Covidien OxiMax adult finger probe sensor — compatible with M3001A Option A04 via M1943NL adapter
D-YS Nellcor Covidien OxiMax adult ear clip sensor — compatible with M3001A Option A04 via M1943NL adapter
Nellcor DB9 MultiSite sensor Nellcor OxiMax multisite sensor — compatible with M3001A Option A04 via M1943NL adapter; contact IPR Medical to confirm current part number and availability

NIBP Cuffs and Hoses

M1599B Philips NIBP single hose, male-to-female metal connector — replacement NBP hose compatible with M3001A
M3918A Philips NIBP single hose — replacement NBP hose compatible with M3001A
Adult NIBP cuffs Single-patient and reusable adult NBP cuffs compatible with the M3001A NBP hose connection — contact IPR Medical to confirm sizing and part number availability
Pediatric / neonatal NIBP cuffs Pediatric and neonatal cuff sizes compatible with the M3001A — contact IPR Medical to confirm current availability

Cables and Connectivity

MSL cable Measurement Link cable — connects the M3001A to the host IntelliVue monitor when the module is not directly docked; carries power, data, and network communication

IPR Medical buys, sells, repairs, and stocks parts for the Philips IntelliVue M3001A. Contact IPR Medical at 855-477-8866 or cs@iprmed.com with service or software questions.